Re-engineering ventilatory support to decrease days and improve resource utilization

被引:15
作者
Kirton, OC
DeHaven, CB
HudsonCivetta, J
Morgan, JP
Windsor, J
Civetta, JM
机构
关键词
D O I
10.1097/00000658-199609000-00016
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective The objective of this study was to describe the development of a cost-effective ventilatory strategy using a portable microprocessor-controlled respiratory monitor (Bicore CP-100; Allied Healthcare Products, Riverside, CA). Summary Background Data Until recently, clinicians have had to accept the uncertainties of clinical judgment, which unfortunately, often biased the patient to a prolonged ventilatory course to avoid extubation failures, necessitating reintubation. Methods Over a 4-year period, the authors attempted to re-engineer the process of ventilatory support based on measured work of breathing (WOB),including physiologic (WOBPhys), imposed (WOBimp) and total (WOBTot). Results The authors made 90 determinations of WOB in 31 patients. The coefficient of determination (r(2)) of WOBTot, with the breathing frequency was 0.35, with tidal volume was 0.10, and with the rapid shallow breathing index (f/V-tau,) was 0.23; therefore, the authors discarded them as reliable inferences. Of 27 patients ventilated for >2 days with satisfactory blood gases, but with breathing frequency > 30 breaths/minute, 6 had WOBTot < 0.8 J/L and were extubated successfully. In 21 patients, WOBTot was elevated to 1.6 +/- 0.83 J/L, WOBimp was 1.1 +/- 0.64 J/L, approximately twice the WOBPhys (0.5 +/- 0.26 J/L), a normal value. Extubation was successful in 20 of those 21 patients. This approach was extended to the spontaneous breathing pre-extubation trial, In addition, the ventilator was adjusted so that the patient sustained a WOBTot of 0.6 to 1 J/L during the ventilatory support. This evolution was tracked for 18 months in a series of 838 trauma intensive care unit patients. Average duration of ventilation decreased from 8.2 to 4.2 days (49%; p < 0.01). This translated into approximately 2400 decreased ventilator days per year. Conclusion Objective measurement to guide the adequacy of ventilatory support and interpret apparent clinical weaning failures decreased total ventilatory time by 50%, permitting extubation in nearly 20% of patients previously considered failures.
引用
收藏
页码:396 / 402
页数:7
相关论文
共 31 条
[1]   DECREASING IMPOSED WORK OF THE BREATHING APPARATUS TO ZERO USING PRESSURE-SUPPORT VENTILATION [J].
BANNER, MJ ;
KIRBY, RR ;
BLANCH, PB ;
LAYON, AJ .
CRITICAL CARE MEDICINE, 1993, 21 (09) :1333-1338
[2]   IMPOSED WORK OF BREATHING AND METHODS OF TRIGGERING A DEMAND-FLOW, CONTINUOUS POSITIVE AIRWAY PRESSURE SYSTEM [J].
BANNER, MJ ;
BLANCH, PB ;
KIRBY, RR .
CRITICAL CARE MEDICINE, 1993, 21 (02) :183-190
[3]   COMPONENTS OF THE WORK OF BREATHING AND IMPLICATIONS FOR MONITORING VENTILATOR-DEPENDENT PATIENTS [J].
BANNER, MJ ;
JAEGER, MJ ;
KIRBY, RR .
CRITICAL CARE MEDICINE, 1994, 22 (03) :515-523
[4]   EFFECTS OF EXPIRATORY FLOW RESISTANCE ON INSPIRATORY WORK OF BREATHING [J].
BANNER, MJ ;
DOWNS, JB ;
KIRBY, RR ;
SMITH, RA ;
BOYSEN, PG ;
LAMPOTANG, S .
CHEST, 1988, 93 (04) :795-799
[5]   BREATHING FREQUENCY AND PATTERN ARE POOR PREDICTORS OF WORK OF BREATHING IN PATIENTS RECEIVING PRESSURE SUPPORT VENTILATION [J].
BANNER, MJ ;
KIRBY, RR ;
KIRTON, OC ;
DEHAVEN, CB ;
BLANCH, PB .
CHEST, 1995, 108 (05) :1338-1344
[6]  
BAYDUR A, 1982, AM REV RESPIR DIS, V126, P788
[7]   ADDITIONAL WORK OF BREATHING IMPOSED BY ENDOTRACHEAL-TUBES, BREATHING CIRCUITS, AND INTENSIVE-CARE VENTILATORS [J].
BERSTEN, AD ;
RUTTEN, AJ ;
VEDIG, AE ;
SKOWRONSKI, GA .
CRITICAL CARE MEDICINE, 1989, 17 (07) :671-677
[8]  
BOLDER PM, 1986, ANESTH ANALG, V65, P853
[9]  
BOYSEN P G, 1987, Respiratory Care, V32, P572
[10]  
CHEATAM ML, 1993, CRIT CARE MED, V21, P244