Strategies for decreasing ascorbate interference at glucose oxidase-modified poly(o-phenylenediamine)-coated electrodes

被引:45
作者
McAteer, K [1 ]
ONeill, RD [1 ]
机构
[1] NATL UNIV IRELAND UNIV COLL DUBLIN,DEPT CHEM,DUBLIN 4,IRELAND
关键词
enzyme-modified polymer-coated electrode; glucose oxidase; ascorbic acid interference; lipid-modified electrode; amperometry;
D O I
10.1039/an9962100773
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Monitoring glucose using biosensors in biological systems is complicated by the presence of reducing agents such as ascorbic acid (AA), This is particularly so in brain extracellular fluid (ECF), where glucose concentrations may be as low as 1 mmol l(-1) and AA levels are approximately 500 mu mol l(-1), Since glucose oxidase-modified poly(o-phenylenediamine)-coated Pt (Pt/PPD/GOx) electrodes show good stability in vivo, glucose sensitivity and AA-blocking properties, attempts were made to improve the latter characteristic further by two distinct strategies: incorporating non-enzyme protein into the polymer film and underlaying the polymer with a lipid coat, Both tactics significantly decreased interference by AA without changing the sensitivity to glucose, the lipid modification being the more effective, The current ratio I-Gluc/I-AA for 1 mmol l(-1) glucose and 500 mu mol l(-1) AA for the best 50% of the lipid-modified Pt/PPD/GOx electrodes was approximately 30:1, indicating that these sensors are well suited for monitoring brain glucose in vivo.
引用
收藏
页码:773 / 777
页数:5
相关论文
共 28 条
[1]   EFFECTS OF RESTRICTED DIFFUSION AT ULTRAMICROELECTRODES IN BRAIN-TISSUE - THE POOL MODEL - THEORY AND EXPERIMENT FOR CHRONOAMPEROMETRY [J].
AMATORE, C ;
KELLY, RS ;
KRISTENSEN, EW ;
KUHR, WG ;
WIGHTMAN, RM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1986, 213 (01) :31-42
[2]   A MICROELECTROCHEMICAL ENZYME TRANSISTOR RESPONSIVE TO GLUCOSE [J].
BARTLETT, PN ;
BIRKIN, PR .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :1552-1559
[3]   ENZYME PACKED-BED SYSTEM FOR THE ONLINE MEASUREMENT OF GLUCOSE, GLUTAMATE, AND LACTATE IN BRAIN MICRODIALYSATE [J].
BOUTELLE, MG ;
FELLOWS, LK ;
COOK, C .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1790-1794
[4]   ELECTROCHEMICALLY PREPARED GLUCOSE BIOSENSORS - KINETIC AND FARADAIC PROCESSES INVOLVING ASCORBIC-ACID AND ROLE OF THE ELECTROPOLYMERIZED FILM IN PREVENTING ELECTRODE-FOULING [J].
CENTONZE, D ;
GUERRIERI, A ;
PALMISANO, F ;
TORSI, L ;
ZAMBONIN, PG .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 349 (07) :497-501
[5]   DISRUPTIVE EFFECTS OF PROTEIN ON PERFORMANCE OF LIQUID MEMBRANE-BASED ION-SELECTIVE MICROELECTRODE [J].
COOMBS, HV ;
MILLER, AJ ;
SANDERS, D .
AMERICAN JOURNAL OF PHYSIOLOGY-CELL PHYSIOLOGY, 1994, 267 (04) :C1027-C1035
[6]   ELECTROPOLYMERIZED O-PHENYLENEDIAMINE FILM AS MEANS OF IMMOBILISING LACTATE OXIDASE FOR A L-LACTATE BIOSENSOR [J].
DEMPSEY, E ;
WANG, J ;
SMYTH, MR .
TALANTA, 1993, 40 (03) :445-451
[7]  
FELLOWS LK, 1992, J NEUROCHEM, V59, P2141
[8]   THE INFLUENCE OF OVEROXIDATION TREATMENT ON THE PERMEABILITY OF POLYPYRROLE FILMS [J].
GAO, ZQ ;
ZI, MX ;
CHEN, BS .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 373 (1-2) :141-148
[9]   SENSING WITH CHEMICALLY AND BIOLOGICALLY MODIFIED CARBON ELECTRODES [J].
GILMARTIN, MAT ;
HART, JP .
ANALYST, 1995, 120 (04) :1029-1045
[10]   THE ORIGIN OF CIRCADIAN AND AMPHETAMINE-INDUCED CHANGES IN THE EXTRACELLULAR CONCENTRATION OF BRAIN ASCORBATE [J].
GRUNEWALD, RA ;
ONEILL, RD ;
FILLENZ, M ;
ALBERY, WJ .
NEUROCHEMISTRY INTERNATIONAL, 1983, 5 (06) :773-778