Removal of activated complement from shed blood: comparison of high- and low-dilutional haemofiltration

被引:8
作者
Arnestad, JP
Hyllner, M
Bengtson, JP
Tylman, M
Mollnes, TE
Bengtsson, A [1 ]
机构
[1] Sahlgrens Univ Hosp, Dept Anaesthesiol & Intens Care, S-41345 Gothenburg, Sweden
[2] Nordland Cent Hosp, Dept Transfus Med, Bodo, Norway
[3] Univ Tromso, N-9001 Tromso, Norway
关键词
autologous blood transfusion; complement activation; complement; 3a; 5a; hemofiltration; terminal complement complex;
D O I
10.1111/j.1399-6576.1998.tb05327.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Perioperative blood salvage is associated with release of inflammatory mediators. Depending on type of processing, the complement system is activated to some extent in the final blood product. The aim of the present study was to evaluate a haemofiltration technique concerning complement system activation and whether the volume of added saline will have an influence on the elimination of activated complement during processing. Methods: Sixteen patients undergoing total hip arthroplasty received wound blood salvaged intraoperatively with a haemofiltration technique. Saline was added to the reservoir for washing in a ratio of 1:1 or 5:1 of estimated blood volume. Samples for determination of the anaphylatoxins C3a and C5a, and the terminal SC5b-9 complement complex (TCC) were drawn from the patients, the collected blood, the ultrafiltrate and the processed blood. Results: Increased concentrations of C3a, C5a and TCC were found in aspirated and processed blood. Haemofiltration did not reduce the concentrations of these factors, except that of C3a in the group where saline was added in a ratio of 5:1. There were no increased concentrations of C3a, C5a or TCC in the patient plasma after reinfusion. No differences in blood pressure, heart rate, pH, arterial oxygen tension, arterial carbon dioxide tension, or base excess were found in association with reinfusion of the blood. Conclusion: Collected shed blood washed through haemofiltration contained moderately elevated concentrations of C3a, C5a and TCC Reinfusion of the blood neither led to increased systemic concentrations of complement activation products, nor to disturbances in haemodynamic or biochemical parameters.
引用
收藏
页码:811 / 815
页数:5
相关论文
共 15 条
[1]   FORMATION OF CYTOKINES BY RETRANSFUSION OF SHED WHOLE-BLOOD [J].
ARNESTAD, JP ;
BENGTSSON, A ;
BENGTSON, JP ;
TYLMAN, M ;
REDL, H ;
SCHLAG, G .
BRITISH JOURNAL OF ANAESTHESIA, 1994, 72 (04) :422-425
[2]   RELEASE OF CYTOKINES, POLYMORPHONUCLEAR ELASTASE AND TERMINAL C5B-9 COMPLEMENT COMPLEX BY INFUSION OF WOUND DRAINAGE BLOOD [J].
ARNESTAD, JP ;
BENGTSSON, A ;
BENGTSON, JP ;
JOHANSSON, S ;
REDL, H ;
SCHLAG, G .
ACTA ORTHOPAEDICA SCANDINAVICA, 1995, 66 (04) :334-338
[3]   ANAPHYLATOXIN AND TERMINAL COMPLEMENT COMPLEXES IN RED-CELL SALVAGE [J].
BENGTSSON, A ;
LISANDER, B .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1990, 34 (05) :339-341
[4]   REINFUSION OF SHED BLOOD AFTER ORTHOPEDIC PROCEDURES IN CHILDREN AND ADOLESCENTS [J].
BLEVINS, FT ;
SHAW, B ;
VALERI, CR ;
KASSER, J ;
HALL, J .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (03) :363-371
[5]   ACTIVATION OF COMPLEMENT BY HEMODIALYSIS MEMBRANES - POLYACRYLONITRILE BINDS MORE C3A THAN CUPROPHAN [J].
CHEUNG, AK ;
PARKER, CJ ;
WILCOX, LA ;
JANATOVA, J .
KIDNEY INTERNATIONAL, 1990, 37 (04) :1055-1059
[6]   SALVAGE AND REINFUSION OF POSTOPERATIVE SANGUINEOUS WOUND DRAINAGE - A PRELIMINARY-REPORT [J].
CLEMENTS, DH ;
SCULCO, TP ;
BURKE, SW ;
MAYER, K ;
LEVINE, DB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (05) :646-651
[7]   UNWASHED FILTERED SHED BLOOD COLLECTED AFTER KNEE AND HIP ARTHROPLASTIES - A SOURCE OF AUTOLOGOUS RED-BLOOD-CELLS [J].
FARIS, PM ;
RITTER, MA ;
KEATING, EM ;
VALERI, CR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (08) :1169-1178
[8]   APPARENT COAGULOPATHY CAUSED BY INFUSION OF SHED MEDIASTINAL BLOOD AND ITS PREVENTION BY WASHING OF THE INFUSATE [J].
GRIFFITH, LD ;
BILLMAN, GF ;
DAILY, PO ;
LANE, TA .
ANNALS OF THORACIC SURGERY, 1989, 47 (03) :400-406
[9]   QUANTIFICATION OF THE TERMINAL COMPLEMENT COMPLEX IN HUMAN-PLASMA BY AN ENZYME-LINKED IMMUNOSORBENT-ASSAY BASED ON MONOCLONAL-ANTIBODIES AGAINST A NEOANTIGEN OF THE COMPLEX [J].
MOLLNES, TE ;
LEA, T ;
FROLAND, SS ;
HARBOE, M .
SCANDINAVIAN JOURNAL OF IMMUNOLOGY, 1985, 22 (02) :197-202
[10]   ADSORPTION OF COMPLEMENT FACTOR-D BY POLYACRYLONITRILE DIALYSIS MEMBRANES [J].
PASCUAL, M ;
SCHIFFERLI, JA .
KIDNEY INTERNATIONAL, 1993, 43 (04) :903-911