Effect of pressure on critical heat flux in uniformly heated vertical annulus under low flow conditions

被引:41
作者
Chun, SY
Chung, HJ
Moon, SK
Yang, SK
Chung, MK
Schoesse, T
Aritomi, M
机构
[1] Korea Atom Energy Res Inst, Taejon 305353, South Korea
[2] Tokyo Inst Technol, Nucl Reactors Res Lab, Meguro Ku, Tokyo 152, Japan
关键词
D O I
10.1016/S0029-5493(00)00307-1
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Critical heat flux (CHF) experiments have been carried out in a wide range of pressure for an internally heated vertical annulus. The experimental conditions covered a range of pressure from 0.57 to 15.01 MPa, mass fluxes of 0 kg m(-2) s(-1) and from 200 to 650 kg m(-2) s(-1), and inlet subcoolings from 85 to 413 kJ kg(-1). Most of the CHFs were identified to the dryout of the liquid him in the annular-mist flow. For the mass fluxes of 550 and 650 kg m(-2) s(-1), the CHFs had a maximum value at a pressure of 2-3 MPa, and the pressure at the maximum CHF values had a trend moving toward the pressure at the peak value of pool boiling CHF as the mass flux decreased. The CHF data under a zero mass flux condition indicate that both the effects of pressure and inlet subcooling on the CHF were smaller, compared with those for the CHF with a net water upflow. The Doerffer correlation using the 1995 CHF look-up table and the Bowring correlation show a good prediction capability for the present CHF data. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:159 / 174
页数:16
相关论文
共 26 条
[1]  
*ASME, 1985, 191 ANSIASME PTC 1
[2]   An independent assessment of Groeneveld et al.'s 1995 CHF look-up table [J].
Baek, WP ;
Kim, HC ;
Chang, SH .
NUCLEAR ENGINEERING AND DESIGN, 1997, 178 (03) :331-337
[3]  
BARNETT PG, 1966, AEEWR463
[4]  
BECKER K, 1965, AE177 AKT AT
[5]  
BIASI L, 1967, ENERG NUCL-MILAN, V14, P530
[6]  
BOWDITCH FH, 1987, AEEWR2050
[7]  
BOWRING RW, 1977, HEAT FLUID FLOW WATE, P175
[8]   A COMPARISON OF CRITICAL HEAT-FLUX IN TUBES AND ANNULI [J].
DOERFFER, S ;
GROENEVELD, DC ;
CHENG, SC ;
RUDZINSKI, KF .
NUCLEAR ENGINEERING AND DESIGN, 1994, 149 (1-3) :167-175
[9]   EXPERIMENTAL STUDIES OF CRITICAL HEAT-FLUX FOR LOW FLOW OF WATER IN VERTICAL ANNULI AT NEAR ATMOSPHERIC-PRESSURE [J].
ELGENK, MS ;
HAYNES, SJ ;
KIM, SH .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1988, 31 (11) :2291-2304
[10]  
Groeneveld D.C., 1986, Heat Transf. Eng., V7, P46