Union of capillary high-performance liquid chromatography and microcoil nuclear magnetic resonance spectroscopy applied to the separation and identification of terpenoids

被引:46
作者
Lacey, ME
Tan, ZJ
Webb, AG
Sweedler, JV [1 ]
机构
[1] Univ Illinois, Dept Chem, Urbana, IL 61801 USA
[2] Univ Illinois, Beckman Inst, Urbana, IL 61801 USA
[3] Univ Illinois, Dept Elect & Comp Engn, Urbana, IL 61801 USA
关键词
nuclear magnetic resonance spectroscopy; capillary liquid chromatography; microfluidics; detection; LC; terpenoids;
D O I
10.1016/S0021-9673(01)00912-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes the first coupling of a commercial capillary HPLC system with a diode array spectrophotometric detector and a custom-built nuclear magnetic resonance (NMR) flow microprobe. The eluent from a 3-mum diameter C-18 HPLC column is linked to a 500 MHz H-1-NMR microcoil probe with an observe volume of 1.1 mul. The separation and structurally-rich detection of a mixture of terpenoids under both isocratic and gradient solvent elution conditions is presented. The lowest limits of detection yet reported for capillary HPLC on-line measurement (i.e., 37 ng for alpha -pinene) are achieved with this system. The complementary nature of diode array and NMR detection allows stopped-flow data collection from analytes which would otherwise go unnoticed in continuous-flow NMR. Moreover, stopped-how NMR data is presented for the detection of a trace (sub-nmol) impurity in the sample mixture. Since NMR signals degrade and shift during solvent gradients, flow injection analysis studies are conducted with injected solvent plugs differing in mobile phase composition. The NMR signal degradation accompanying these injections is largely due to the variance in chemical shift with the solvent composition rather than to changes in magnetic susceptibility of the solvent. Characterization of such effects enables the development of improved NMR probes for the coupling of capillary HPLC and NMR. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:139 / 149
页数:11
相关论文
共 43 条
[1]   Application of on-line capillary high-performance liquid chromatography nuclear magnetic resonance spectrometry coupling for the analysis of vitamin A derivatives [J].
Albert, K ;
Schlotterbeck, G ;
Tseng, LH ;
Braumann, U .
JOURNAL OF CHROMATOGRAPHY A, 1996, 750 (1-2) :303-309
[2]   CYLINDRICAL DEMAGNETIZATION FIELDS AND MICROPROBE DESIGN IN HIGH-RESOLUTION NMR [J].
BARBARA, TM .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1994, 109 (02) :265-269
[3]   ONLINE COUPLING OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND NUCLEAR MAGNETIC-RESONANCE [J].
BAYER, E ;
ALBERT, K ;
NIEDER, M ;
GROM, E .
JOURNAL OF CHROMATOGRAPHY, 1979, 186 (DEC) :497-507
[4]  
Beaupre DM, 1999, CANCER RES, V59, P2971
[5]   Capillary HPLC-NMR coupling high-resolution NMR spectroscopy in the nanoliter scale [J].
Behnke, B ;
Schlotterbeck, G ;
Tallarek, U ;
Strohschein, S ;
Tseng, LH ;
Keller, T ;
Albert, K ;
Bayer, E .
ANALYTICAL CHEMISTRY, 1996, 68 (07) :1110-1115
[6]   Application of liquid chromatography-nuclear magnetic resonance spectroscopy to the identification of natural products [J].
Bobzin, SC ;
Yang, ST ;
Kasten, TP .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 748 (01) :259-267
[7]  
Cohen S, 1999, AM LAB, V31, P28
[8]   THE NATURE OF FULLERENE SOLUTION COLLISIONAL DYNAMICS - A C-13 DNP AND NMR-STUDY OF THE C60/C6D6/TEMPO SYSTEM [J].
DORN, HC ;
GU, J ;
BETHUNE, DS ;
JOHNSON, RD ;
YANNONI, CS .
CHEMICAL PHYSICS LETTERS, 1993, 203 (5-6) :549-554
[9]   Optimal use of cryogenic probe technology in NMR studies of proteins [J].
Flynn, PF ;
Mattiello, DL ;
Hill, HDW ;
Wand, AJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2000, 122 (19) :4823-4824
[10]  
Gfrörer P, 1999, ELECTROPHORESIS, V20, P3, DOI 10.1002/(SICI)1522-2683(19990101)20:1<3::AID-ELPS3>3.3.CO