Long-term outcomes in patients with atrioventricular block undergoing septal ventricular lead implantation compared with standard apical pacing

被引:64
作者
Kypta, Alexander [1 ]
Steinwender, Clemens [1 ]
Kammler, Juergen [1 ]
Leisch, Franz [1 ]
Hofmann, Robert [1 ]
机构
[1] Acad Teaching & Gen Hosp Linz, Div Cardiovasc, Dept Internal Med 1, A-4020 Linz, Austria
来源
EUROPACE | 2008年 / 10卷 / 05期
关键词
apical pacing; septal pacing; ventricular function; congestive heart failure;
D O I
10.1093/europace/eun085
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Left ventricular function may be altered by right ventricular apical pacing. The aims of the study were to compare the long-term course of different parameters of left ventricular dysfunction in patients undergoing implantation of a dual-chamber pacemaker with the ventricular lead in a septal position vs. in a standard apical position. Methods We randomized 98 patients with atrioventricular block (AV-block) undergoing pacemaker implantation to positioning the ventricular lead in the high or mid septum (n = 53) or in the apex (n = 45) of the right ventricle. N-terminal pro-brain natriuetic peptide (BNP) levels, left ventricular ejection fraction (LVEF), and exercise capacity were analysed 3 days, 3 months, and 18 months after the implantation. The primary endpoints were the changes of these parameters from baseline to 18 months. Results Changes of BNP levels, LVEF, and exercise capacity from baseline to 18 months were statistically not different between septal and apical stimulation. The clinical occurrence or deterioration of overt heart failure was similar in both treatment arms. Conclusion With regard to different parameters of congestive heart failure, a septal stimulation site is not superior to conventional apical pacing in unselected patients undergoing pacemaker implantation for AV-block.
引用
收藏
页码:574 / 579
页数:6
相关论文
共 29 条
[1]   Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance - Are they interchangeable? [J].
Bellenger, NG ;
Burgess, MI ;
Ray, SG ;
Lahiri, A ;
Coats, AJS ;
Cleland, JGF ;
Pennell, DJ .
EUROPEAN HEART JOURNAL, 2000, 21 (16) :1387-1396
[2]   The effect of cardiac resynchronization on morbidity and mortality in heart failure [J].
Cleland, JGF ;
Daubert, J ;
Erdmann, E ;
Freemantle, N ;
Gras, D ;
Kappenberger, L ;
Tavazzi, L ;
Cleland, JGF ;
Daubert, JC ;
Erdmann, E ;
Gras, D ;
Kappenberger, L ;
Klein, W ;
Tavazzi, L ;
Poole-Wilson, PA ;
Rydén, L ;
Wedel, H ;
Wellens, HJJ ;
Uretsky, B ;
Thygesen, K ;
Böcker, D ;
Marijianowski, MMH ;
Freemantle, N ;
Calvert, MJ ;
Christ, G ;
Fruhwald, F ;
Hofmann, R ;
Krypta, A ;
Leisch, F ;
Pacher, R ;
Rauscha, F ;
Tavernier, R ;
Thomsen, PEB ;
Boesgaard, S ;
Eiskjær, H ;
Esperen, GT ;
Haarbo, J ;
Hagemann, A ;
Korup, E ;
Moller, M ;
Mortensen, P ;
Sogaard, P ;
Vesterlund, T ;
Huikuri, H ;
Niemelä, KI ;
Toivonen, L ;
Bauer, F ;
Cohen-Solal, A ;
Crocq, C ;
Djiane, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (15) :1539-1549
[3]   Early and sustained effects of cardiac resynchronization therapy on N-terminal pro-B-type natriuretic peptide in patients with moderate to severe heart failure and cardiac dyssynchrony [J].
Fruhwald, Friedrich M. ;
Fahrleitner-Pammer, Astrid ;
Berger, Rudolf ;
Leyva, Francisco ;
Freemantle, Nick ;
Erdmann, Erland ;
Gras, Daniel ;
Kappenberger, Lukas ;
Tavazzi, Luigi ;
Daubert, Jean-Claude ;
Cleland, John G. F. .
EUROPEAN HEART JOURNAL, 2007, 28 (13) :1592-1597
[4]   ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices - Summary article - A report of the American College of Cardiology American Heart Association task force on practice guidelines - (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines) [J].
Gregoratos, G ;
Abrams, J ;
Epstein, AE ;
Freedman, RA ;
Hayes, DL ;
Hlatky, MA ;
Kerber, RE ;
Naccarelli, GV ;
Schoenfeld, MH ;
Silka, MJ ;
Winters, SL ;
Gibbons, RJ ;
Antman, EM ;
Alpert, JS ;
Gregoratos, G ;
Hiratzka, LF ;
Faxon, DP ;
Jacobs, AK ;
Fuster, V ;
Smith, SC .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (09) :1703-1719
[5]   ENDOCARDIAL PACING SITE AFFECTS LEFT-VENTRICULAR END-DIASTOLIC VOLUME AND PERFORMANCE IN THE INTACT ANESTHETIZED DOG [J].
GROVER, M ;
GLANTZ, SA .
CIRCULATION RESEARCH, 1983, 53 (01) :72-85
[6]   Electrocardiographic features of septal location of right ventricular outflow tract tachycardia [J].
Gumbrielle, TP ;
Bourke, JP ;
Doig, JC ;
Kamel, A ;
Loaiza, A ;
Fang, Q ;
Campbell, RWF ;
Furniss, SS .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (02) :213-&
[7]   Upgrade to biventricular pacing in patients with conventional pacemakers and heart failure:: a double-blind, randomized crossover study [J].
Höijer, CJ ;
Meurling, C ;
Brandt, J .
EUROPACE, 2006, 8 (01) :51-55
[8]   Effect of right ventricular apex pacing on the Tei index and brain natriuretic peptide in patients with a dual-chamber pacemaker [J].
Ichiki, Hitoshi ;
Oketani, Naoya ;
Hamasaki, Shuichi ;
Ishida, Sanemasa ;
Kataoka, Tetsuro ;
Ogawa, Masakazu ;
Saihara, Keishi ;
Okui, Hideki ;
Fukudome, Tsuyoshi ;
Shinasato, Takuro ;
Kubozono, Takuro ;
Ninomiya, Yuichi ;
Matsushita, Takehiko ;
Otsuji, Yutaka ;
Tei, Chuwa .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (09) :985-990
[9]   HEMODYNAMIC IMPORTANCE OF PRESERVING THE NORMAL SEQUENCE OF VENTRICULAR ACTIVATION IN PERMANENT CARDIAC PACING [J].
LECLERCQ, C ;
GRAS, D ;
LEHELLOCO, A ;
NICOL, L ;
MABO, P ;
DAUBERT, C .
AMERICAN HEART JOURNAL, 1995, 129 (06) :1133-1141
[10]   Selective site pacing: Defining and reaching the selected site [J].
Lieberman, R ;
Grenz, D ;
Mond, HG ;
Gammage, MD .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (06) :883-886