Flow injection for the determination of Se(IV) and Se(VI) by hydride generation atomic absorption spectrometry with microwave oven on-line prereduction of Se(VI) to Se(IV)

被引:40
作者
Burguera, JL
Carrero, P
Burguera, M
Rondon, C
Brunetto, MR
Gallignani, M
机构
[1] IVAIQUIM Venezuelan Andean Inst. C., Faculty of Sciences, University of Los Andes, 5101-A Merida
关键词
citric fruit juices; geothermal waters; hydride generation; on-line flow injection; Se(IV); Se(VI);
D O I
10.1016/S0584-8547(96)01521-2
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
An on-line flow injection system has been developed for the selective determination of Se(IV) and Se(VI) in citric fruit juices and geothermal waters by hydride generation atomic absorption spectrometry with microwave-aided heating prereduction of Se(VI) to Se(IV). The samples and the prereductant solutions (4 mol l(-1) HCl for Se(IV) and 12 mol l(-1) HCl for Se(VI)) which circulated in a closed-flow circuit were injected by means of a time-based injector. This mixture was displaced by a carrier solution of 1% v/v of hydrochloric acid through a PTFE coil located inside the focused microwave oven and mixed downstream with a borohydride solution to generate the hydride. The linear ranges were 0-120 and 0-100 mu g l(-1) of Se(IV) and Se(VI), respectively. The detection limits were 1.0 mu g l(-1) for Se(IV) and 1.5 mu g l(-1) for Se(VI). The precision (about 2.0-2.5% RSD) and recoveries (96-98% for Se(IV) and 94-98% for Se(VI)) were good. Total selenium values were also obtained by electrothermal atomic absorption spectrometry which agreed with the content of both selenium species. The sample throughput was about 50 measurements per hour. The main advantage of the method is that the selective determination of Se(IV) and Se(VI) in citric fruit juices and geothermal waters is performed in a closed system with a minimum sample manipulation, exposure to the environment, minimum sample waste and operator attention.
引用
收藏
页码:1837 / 1847
页数:11
相关论文
共 31 条
[1]   A STUDY ON THE GENERATION OF HYDROGEN SELENIDE AND DECOMPOSITION OF TETRAHYDROBORATE IN HYDRIDE-GENERATION ATOMIC-ABSORPTION SPECTROMETRY [J].
AGTERDENBOS, J ;
BAX, D .
ANALYTICA CHIMICA ACTA, 1986, 188 :127-135
[2]  
ALAEJOS MS, 1995, CHEM REV, V95, P227
[3]   DETERMINATION OF SELENIUM IN FRUIT JUICES BY FLOW-INJECTION ELECTROTHERMAL ATOMIZATION ATOMIC-ABSORPTION SPECTROMETRY [J].
ARRUDA, MAZ ;
GALLEGO, M ;
VALCARCEL, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (05) :657-662
[4]   FLOW-INJECTION ANODIC-STRIPPING VOLTAMMETRY AT A GOLD ELECTRODE FOR SELENIUM(IV) DETERMINATION [J].
BRYCE, DW ;
IZQUIERDO, A ;
DECASTRO, MDL .
ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) :96-101
[5]   ONLINE ION-EXCHANGE FOR THE REMOVAL OF SULFUR ANION INTERFERENCE ON THE DETERMINATION OF MANGANESE IN GEOTHERMAL FLUIDS BY FLOW-INJECTION ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BURGUERA, JL ;
BURGUERA, M ;
RIVAS, C ;
CARRERO, P ;
GALLIGNANI, M ;
BRUNETTO, MR .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (07) :479-482
[6]   GASTRIC TISSUE SELENIUM LEVELS IN HEALTHY-PERSONS, CANCER AND NONCANCER PATIENTS WITH DIFFERENT KINDS OF MUCOSAL DAMAGE [J].
BURGUERA, JL ;
VILLASMIL, LM ;
BURGUERA, M ;
CARRERO, P ;
RONDON, C ;
DELACRUZ, AMDA ;
BRUNETTO, MR ;
GALLIGNANI, M .
JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 1995, 9 (03) :160-164
[7]  
BURGUERA JL, 1983, AGUAS TERMALES ESTAD, P10
[8]   TIME-BASED DEVICE USED FOR THE DETERMINATION OF TIN BY HYDRIDE GENERATION FLOW-INJECTION ATOMIC-ABSORPTION TECHNIQUES [J].
BURGUERA, M ;
BURGUERA, JL ;
RIVAS, C ;
CARRERO, P ;
BRUNETTO, R ;
GALLIGNANI, M .
ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) :339-348
[9]  
BURGUERA M, 1991, ANAL CHIM ACTA, V261, P105
[10]   A TIME-BASED INJECTOR APPLIED TO THE FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF BORON IN PLANT MATERIALS AND SOILS [J].
CARRERO, P ;
BURGUERA, JL ;
BURGUERA, M ;
RIVAS, C .
TALANTA, 1993, 40 (12) :1967-1974