Patch-based generation of a pseudo CT from conventional MRI sequences for MRI-only radiotherapy of the brain

被引:116
作者
Andreasen, Daniel [1 ,2 ]
Van Leemput, Koen [1 ,3 ]
Hansen, Rasmus H. [4 ]
Andersen, Jon A. L. [2 ]
Edmund, Jens M. [2 ]
机构
[1] Tech Univ Denmark, Dept Appl Math & Comp Sci, DK-2800 Lyngby, Denmark
[2] Copenhagen Univ Hosp, Radiotherapy Res Unit, Dept Oncol, DK-2730 Herlev, Denmark
[3] Harvard Univ, Sch Med, MGH, AA Martinos Ctr Biomed Imaging, Charlestown, MA 02129 USA
[4] Copenhagen Univ Hosp, Dept Radiol, DK-2730 Herlev, Denmark
关键词
radiotherapy; magnetic resonance imaging; pseudo CT; MRI-only; patches; ATTENUATION CORRECTION; PROSTATE; PET/MRI; SEGMENTATION; DELINEATION; QUALITY; TIME;
D O I
10.1118/1.4914158
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In radiotherapy (RT) based on magnetic resonance imaging (MRI) as the only modality, the information on electron density must be derived from the MRI scan by creating a so-called pseudo computed tomography (pCT). This is a nontrivial task, since the voxel-intensities in an MRI scan are not uniquely related to electron density. To solve the task, voxel-based or atlas-based models have typically been used. The voxel-based models require a specialized dual ultrashort echo time MRI sequence for bone visualization and the atlas-based models require deformable registrations of conventional MRI scans. In this study, we investigate the potential of a patch-based method for creating a pCT based on conventional T-1-weighted MRI scans without using deformable registrations. We compare this method against two state-of-the-art methods within the voxel-based and atlas-based categories. Methods: The data consisted of CT and MRI scans of five cranial RT patients. To compare the performance of the different methods, a nested cross validation was done to find optimal model parameters for all the methods. Voxel-wise and geometric evaluations of the pCTs were done. Furthermore, a radiologic evaluation based on water equivalent path lengths was carried out, comparing the upper hemisphere of the head in the pCT and the real CT. Finally, the dosimetric accuracy was tested and compared for a photon treatment plan. Results: The pCTs produced with the patch-based method had the best voxel-wise, geometric, and radiologic agreement with the real CT, closely followed by the atlas-based method. In terms of the dosimetric accuracy, the patch-based method had average deviations of less than 0.5% in measures related to target coverage. Conclusions: We showed that a patch-based method could generate an accurate pCT based on conventional T-1-weighted MRI sequences and without deformable registrations. In our evaluations, the method performed better than existing voxel-based and atlas-based methods and showed a promising potential for RT of the brain based only on MRI. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:1596 / 1605
页数:10
相关论文
共 38 条
[1]   The value of magnetic resonance imaging in target volume delineation of base of tongue tumours - A study using flexible surface coils [J].
Ahmed, Merina ;
Schmidt, Maria ;
Sohaib, Aslam ;
Kong, Christine ;
Burke, Kevin ;
Richardson, Cheryl ;
Usher, Marianne ;
Brennan, Sinead ;
Riddell, Angela ;
Davies, Mark ;
Newbold, Kate ;
Harrington, Kevin J. ;
Nutting, Christopher M. .
RADIOTHERAPY AND ONCOLOGY, 2010, 94 (02) :161-167
[2]  
Andreasen D., 2013, CREATING PSEUDO CT M
[3]  
[Anonymous], 2010, J ICRU, V10, P27, DOI 10.1093/jicru/ndq008
[4]  
[Anonymous], RAD ONCOL S2
[5]  
Arthur D., posium on Discrete algorithms, P1027
[6]   MRI-Based Attenuation Correction for Hybrid PET/MRI Systems: A 4-Class Tissue Segmentation Technique Using a Combined Ultrashort-Echo-Time/Dixon MRI Sequence [J].
Berker, Yannick ;
Franke, Jochen ;
Salomon, Andre ;
Palmowski, Moritz ;
Donker, Henk C. W. ;
Temur, Yavuz ;
Mottaghy, Felix M. ;
Kuhl, Christiane ;
Izquierdo-Garcia, David ;
Fayad, Zahi A. ;
Kiessling, Fabian ;
Schulz, Volkmar .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (05) :796-804
[7]  
Burgos N, 2013, LECT NOTES COMPUT SC, V8149, P147, DOI 10.1007/978-3-642-40811-3_19
[8]   Target delineation in post-operative radiotherapy of brain gliomas: Interobserver variability and impact of image registration of MR (pre-operative) images on treatment planning CT scans [J].
Cattaneo, GM ;
Reni, M ;
Rizzo, G ;
Castellone, P ;
Ceresoli, GL ;
Cozzarini, C ;
Ferreri, AJM ;
Passoni, P ;
Calandrino, R .
RADIOTHERAPY AND ONCOLOGY, 2005, 75 (02) :217-223
[9]   Patch-based segmentation using expert priors: Application to hippocampus and ventricle segmentation [J].
Coupe, Pierrick ;
Manjon, Jose V. ;
Fonov, Vladimir ;
Pruessner, Jens ;
Robles, Montserrat ;
Collins, D. Louis .
NEUROIMAGE, 2011, 54 (02) :940-954
[10]   MAXIMUM LIKELIHOOD FROM INCOMPLETE DATA VIA EM ALGORITHM [J].
DEMPSTER, AP ;
LAIRD, NM ;
RUBIN, DB .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-METHODOLOGICAL, 1977, 39 (01) :1-38