The applicability of digital PCR for the assessment of detection limits in GMO analysis

被引:104
作者
Burns, M. J. [1 ]
Burrell, A. M. [1 ]
Foy, C. A. [1 ]
机构
[1] Lab Govt Chemist, Teddington TW11 0LY, Middx, England
关键词
Digital PCR; Digital arrays; GMO analysis; Limit of detection; REAL-TIME PCR;
D O I
10.1007/s00217-010-1277-8
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
We investigate the applicability of using digital PCR to estimate absolute limits of detection and quantitation associated with the validation of traditional real-time PCR methods for analysis of genetically modified (GM) ingredients. We also demonstrate the use of dynamic arrays as a precursor in selecting suitable sample dilution levels for accurate copy number assessment using the aforementioned digital PCR. Additionally, we further explore the relevance of digital PCR in accurately quantifying plasmid copy numbers associated with a commercially available Certified Reference Material. The use of digital PCR has the advantage of facilitating absolute single molecule detection, therefore negating the necessity for standards on a calibration curve, and reducing associated matrix effects. The approaches described in this paper enable pre-existing validated protocols to be re-examined, and estimates based on an alternative approach using digital PCR to be used in order to objectively characterise sensitivity limits.
引用
收藏
页码:353 / 362
页数:10
相关论文
共 13 条
  • [1] [Anonymous], 2007, 22948 EUR EN EUR COM, DOI DOI 10.2787/49996
  • [2] Single molecule detection in nanofluidic digital array enables accurate measurement of DNA copy number
    Bhat, Somanath
    Herrmann, Jan
    Armishaw, Paul
    Corbisier, Philippe
    Emslie, Kerry R.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (02) : 457 - 467
  • [3] BioMark, BIOMARK ADV DEV PROT
  • [4] BURNS M, 2009, 42 EU COEXTRA TASK
  • [5] Comparison of plasmid and genomic DNA calibrants for the quantification of genetically modified ingredients
    Burns, Malcolm
    Corbisier, Philippe
    Wiseman, Gordon
    Valdivia, Hernan
    McDonald, Paul
    Bowler, Peter
    Ohara, Katrina
    Schimmel, Heinz
    Charels, Diana
    Damant, Andrew
    Harris, Neil
    [J]. EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2006, 224 (02) : 249 - 258
  • [6] Analysis and interpretation of data from real-time PCR trace detection methods using quantitation of GM soya as a model system
    Burns, MJ
    Valdivia, H
    Harris, N
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (06) : 1616 - 1623
  • [7] *COMM REF LAB GM F, 2008, GUID DOC DEF MIN PER
  • [8] *COMM REF LAB GM F, CRL ASS VAL EV SPEC
  • [9] Mathematical Analysis of Copy Number Variation in a DNA Sample Using Digital PCR on a Nanofluidic Device
    Dube, Simant
    Qin, Jian
    Ramakrishnan, Ramesh
    [J]. PLOS ONE, 2008, 3 (08):
  • [10] Routes to improving the reliability of low level DNA analysis using real-time PCR
    Ellison, Stephen L. R.
    English, Claire A.
    Burns, Malcolm J.
    Keer, Jacquie T.
    [J]. BMC BIOTECHNOLOGY, 2006, 6 (1)