Slow equilibration of reversed-phase columns for the separation of ionized solutes

被引:34
作者
Marchand, DH [1 ]
Williams, LA
Dolan, JW
Snyder, LR
机构
[1] Univ Wisconsin, Dept Chem, River Falls, WI 54022 USA
[2] BASi NW Lab, McMinnville, OR 97128 USA
[3] Rheodyne LLC, LC Resources Grp, Walnut Creek, CA 94596 USA
基金
美国国家卫生研究院;
关键词
column equilibration; ionized solutes;
D O I
10.1016/S0021-9673(03)01216-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Reversed-phase columns that have been stored in buffer-free solvents can exhibit pronounced retention-time drift when buffered, low-pH mobile phases are used with ionized solutes. Whereas non-ionized compounds exhibit constant retention times within 20 min of the beginning of mobile phase flow, the retention of ionized compounds can continue to change (by 20% or more) for several hours. If mobile phase pH is changed from low to high and back again, an even longer time may be required before the column reaches equilibration at low pH. The speed of column equilibration for ionized solutes can vary significantly among different reversed-phase columns and is not affected by flow rate. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:53 / 64
页数:12
相关论文
共 15 条
[1]   REDUCTION OF REEQUILIBRATION TIME FOLLOWING GRADIENT ELUTION REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
COLE, LA ;
DORSEY, JG .
ANALYTICAL CHEMISTRY, 1990, 62 (01) :16-21
[2]   PROPERTIES AND DIVERSITY OF C18 BONDED PHASES [J].
ENGELHARDT, H ;
DREYER, B ;
SCHMIDT, H .
CHROMATOGRAPHIA, 1982, 16 :11-17
[3]   MOVEMENT OF COMPONENTS IN REVERSED-PHASE CHROMATOGRAPHY .3. REGENERATION POLICIES IN LIQUID-CHROMATOGRAPHY [J].
FRENZ, J ;
HORVATH, C .
JOURNAL OF CHROMATOGRAPHY, 1983, 282 (DEC) :249-262
[4]   Column selectivity in reversed-phase liquid chromatography - IV. Type-B alkyl-silica columns [J].
Gilroy, JJ ;
Dolan, JW ;
Snyder, LR .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :757-778
[5]  
Kirkland J. J., 1988, ANAL CHEM, V61, P2
[6]   Wetting of octadecylsilylated silica in methanol-water eluents [J].
Li, ZB ;
Rutan, SC ;
Dong, SN .
ANALYTICAL CHEMISTRY, 1996, 68 (01) :124-129
[7]   Comparative evaluation of bonded-silica reversed-phase columns for high-performance liquid chromatography using strongly basic compounds and alternative organic modifiers buffered at acid pH [J].
McCalley, DV .
JOURNAL OF CHROMATOGRAPHY A, 1997, 769 (02) :169-178
[8]   Comparison of the acidity of residual silanol groups in several liquid chromatography columns [J].
Méndez, A ;
Bosch, E ;
Rosés, M ;
Neue, UD .
JOURNAL OF CHROMATOGRAPHY A, 2003, 986 (01) :33-44
[9]   Dependence of reversed-phase retention of ionizable analytes on pH, concentration of organic solvent and silanol activity [J].
Neue, UD ;
Phoebe, CH ;
Tran, K ;
Cheng, YF ;
Lu, ZL .
JOURNAL OF CHROMATOGRAPHY A, 2001, 925 (1-2) :49-67
[10]   MEASUREMENT AND USE OF RETENTION DATA FROM HIGH-PERFORMANCE GRADIENT ELUTION - CORRECTION FOR NON-IDEAL PROCESSES ORIGINATING WITHIN THE COLUMN [J].
QUARRY, MA ;
GROB, RL ;
SNYDER, LR .
JOURNAL OF CHROMATOGRAPHY, 1984, 285 (01) :19-51