\Near-critical adsorption of CO2 on 13X zeolite and N2O on silica gel:: lack of evidence of critical phenomena

被引:14
作者
Pini, Ronny [1 ]
Ottiger, Stefan [1 ]
Rajendran, Arvind [1 ]
Storti, Giuseppe [2 ]
Mazzotti, Marco [1 ]
机构
[1] ETH, Inst Proc Engn, CH-8092 Zurich, Switzerland
[2] ETH, Inst Chem & Bioengn, CH-8093 Zurich, Switzerland
来源
ADSORPTION-JOURNAL OF THE INTERNATIONAL ADSORPTION SOCIETY | 2008年 / 14卷 / 01期
关键词
supercritical adsorption; gravimetric method; carbon dioxide; nitrous oxide; 13X zeolite; silica gel;
D O I
10.1007/s10450-007-9080-y
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 [物理化学]; 081704 [应用化学];
摘要
The excess adsorption of CO2 on 13X zeolite and of N2O on silica gel has been studied at high pressure using a magnetic suspension balance, i.e. a gravimetric method. Recently, a detailed study on the density distribution in the measuring cell of the magnetic suspension balance showed that a proper approach to thermostatting the unit should be used in order to obtain reliable and accurate excess adsorption measurements. This is particularly important in the vicinity of the critical point of the fluid, where the density is strongly dependent on pressure and temperature. In the past, several effects were observed in our laboratory when measuring near-critical adsorption on 13X zeolite and on silica gel, namely critical adsorption and critical depletion. In the present study, these effects have been checked using the balance in the new thermostatting configuration, and the conclusion can be drawn that the accuracy of the measurement is not sufficient to prove that they indeed occur. More accurate adsorption data for the two systems have been measured and reported.
引用
收藏
页码:133 / 141
页数:9
相关论文
共 21 条
[1]
Adsorption and desorption of carbon dioxide onto and from activated carbon at high pressures [J].
Chen, JH ;
Wong, DSH ;
Tan, CS ;
Subramanian, R ;
Lira, CT ;
Orth, M .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1997, 36 (07) :2808-2815
[2]
Adsorption of supercritical carbon dioxide on silica [J].
Di Giovanni, O ;
Dörfler, W ;
Mazzotti, M ;
Morbidelli, M .
LANGMUIR, 2001, 17 (14) :4316-4321
[3]
DIGIOVANNI O, 2001, FUNDAMENTALS ADS FOA, V7
[4]
Magnetic suspension balance for simultaneous measurement of a sample and the density of the measuring fluid [J].
Dreisbach, F ;
Lösch, HW .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2000, 62 (02) :515-521
[5]
FISHER ME, 1978, CR ACAD SCI B PHYS, V287, P207
[6]
High-pressure adsorption of CO2 on NaY zeolite and model prediction of adsorption isotherms [J].
Gao, WH ;
Butler, D ;
Tomasko, DL .
LANGMUIR, 2004, 20 (19) :8083-8089
[7]
Measuring and Modeling Supercritical adsorption in porous solids. Carbon dioxide on 13X zeolite and on silica gel [J].
Hocker, T ;
Rajendran, A ;
Mazzotti, M .
LANGMUIR, 2003, 19 (04) :1254-1267
[8]
High-resolution adsorption isotherms of supercritical carbon dioxide on activated carbon [J].
Humayun, R ;
Tomasko, DL .
AICHE JOURNAL, 2000, 46 (10) :2065-2075
[9]
Properties of three capillary fluids in the critical region [J].
Machin, WD .
LANGMUIR, 1999, 15 (01) :169-173
[10]
Adsorption of pure carbon dioxide and methane on dry coal from the Sulcis Coal Province (SW Sardinia, Italy) [J].
Ottiger, Stefan ;
Pini, Ronny ;
Storti, Giuseppe ;
Mazzotti, Marco ;
Bencini, Roberto ;
Quattrocchi, Fedora ;
Sardu, Giorgio ;
Derui, Giuseppe .
ENVIRONMENTAL PROGRESS, 2006, 25 (04) :355-364