Influence of gaseous species transport on the response of solid state gas sensors within enclosures

被引:21
作者
Lezzi, AM
Beretta, GP
Comini, E
Faglia, G
Galli, G
Sberveglieri, G
机构
[1] Univ Brescia, INFM, Dept Mech Engn, I-25123 Brescia, Italy
[2] Univ Brescia, INFM, Chem & Phys Mat Dept, I-25133 Brescia, Italy
关键词
gas sensors; measurement chamber; mass transfer; forced convection;
D O I
10.1016/S0925-4005(01)00805-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The filling of a measurement chamber for gas sensor characterization, with CO diluted in air by the flow-through method is simulated by using a general-purpose CID code. Numerical data allow to follow the time evolution of CO concentration at any point inside the chamber, thus representing an helpful tool for designing effective test chambers and for interpreting experimental electrical data. In particular, it is shown that CO concentration over the sensor surface increases with time quite slowly, even if the air-CO jet impinges on the device from a short distance. In addition, a comparison of numerical results with experimental data is presented and discussed. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:144 / 150
页数:7
相关论文
共 3 条
[1]  
BIRD RB, 1950, TRANSPORT PHENOMENA
[2]   RECENT DEVELOPMENTS IN SEMICONDUCTING THIN-FILM GAS SENSORS [J].
SBERVEGLIERI, G .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 23 (2-3) :103-109
[3]   WO3 SPUTTERED THIN-FILMS FOR NOX MONITORING [J].
SBERVEGLIERI, G ;
DEPERO, L ;
GROPPELLI, S ;
NELLI, P .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 26 (1-3) :89-92