Consistency of complex fractionated atrial electrograms during atrial fibrillation

被引:99
作者
Lin, Yenn-Jiang [1 ,2 ,3 ]
Tai, Ching-Tai [1 ]
Kao, Tsair [4 ]
Chang, Shih-Lin [1 ]
Wongcharoen, Wanwarang [2 ,3 ]
Lo, Li-Wei [2 ,3 ]
Tuan, Ta-Chuan [2 ,3 ]
Udyavar, Ameya R. [2 ,3 ]
Chen, Yi-Jen [5 ,6 ]
Higa, Satoshi [7 ]
Ueng, Kuo-Chang [8 ]
Chen, Shih-Ann [1 ,2 ,3 ]
机构
[1] Taipei Vet Gen Hosp, Div Cardiol, Dept Med, Taipei, Taiwan
[2] Natl Yang Ming Univ, Inst Clin Med, Taipei 112, Taiwan
[3] Natl Yang Ming Univ, Cardiovasc Res Ctr, Taipei 112, Taiwan
[4] Natl Yang Ming Univ, Inst Biomed Engn, Taipei 112, Taiwan
[5] Wang Fang Hosp, Taipei, Taiwan
[6] Taipei Med Univ, Taipei, Taiwan
[7] Univ Ryukyus, Fac Med, Dept Internal Med 2, Okinawa, Japan
[8] Chung Shan Med Univ, Taichung, Taiwan
关键词
atrial fibrillation; electrogram; frequency analysis; left atrium; mapping;
D O I
10.1016/j.hrthm.2007.12.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Temporal variation in complex fractionated atrial etectrograms (CFAEs) exists during atria[ fibrillation (AF). OBJECTIVE This study sought to quantify the variation in CFAEs using a fractionation interval (FI) algorithm and to define the shortest optimal recording duration required to consistently characterize the magnitude of the fractionation. METHODS Twenty-seven patients undergoing AF mapping in the Left atrium were studied. The FI and frequency analysis were performed at each mapped site for recording durations of I to 8 seconds. The magnitude of the fractionation was quantified by the FI algorithm, which calculated the mean interval between multiple, discrete deflections during AF. The results from each duration were statistically compared with the maximal-duration recording, as a standard. The FI values were compared with the dominant frequency values obtained from the associated frequency spectra. RESULTS The FIs obtained from recording durations between 5 and 8 seconds had a smaller variation in the FI (P < .05) and, for those sites with a FI < 50 ms, the fractionation was typically continuous. The fast-Fourier Transform spectra obtained from the CFAE sites with recording durations of > 5 seconds harbored higher dominant frequency values than those with shorter recording durations (8.1 +/- 2.5 Hz vs. 6.8 +/- 0.98 Hz, P <.05). The CFAE sites with continuous fractionation were Located within the pulmonary veins and their ostia in 77% of patients with paroxysmal AF, and in only 29% of patients with nonparoxysmal AF (P <.05). CONCLUSION The assessment of fractionated electrograms requires a recording duration of 5 seconds at each site to obtain a consistent fractionation. Sites with the shortest FIs consistently identified sites with the fastest electrograrn activity throughout the entire left atrium and pulmonary veins.
引用
收藏
页码:406 / 412
页数:7
相关论文
共 19 条
[1]   Frequency analysis of human atrial fibrillation using the surface electrocardiogram and its response to ibutilide [J].
Bollmann, A ;
Kanuru, NK ;
McTeague, KK ;
Walter, PF ;
DeLurgio, DB ;
Langberg, JJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (12) :1439-1445
[2]   The efficacy of inducibility and circumferential ablation with pulmonary vein isolation in patients with paroxysmal atrial fibrillation [J].
Chang, Shih-Lin ;
Tai, Ching-Tai ;
Lin, Yenn-Jiang ;
Wongcharoen, Wanwarang ;
Lo, Li-Wei ;
Tuan, Ta-Chuan ;
Udyavar, Ameya R. ;
Chang, Sheng-Hsiung ;
Tsao, Hsuan-Ming ;
Hsieh, Ming-Hsiung ;
Hu, Yu-Feng ;
Chen, Yi-Jen ;
Chen, Shih-Ann .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (06) :607-611
[3]   Non-invasive assessment of the atrial cycle length during atrial fibrillation in man:: introducing, validating and illustrating a new ECG method [J].
Holm, M ;
Pehrson, S ;
Ingemansson, M ;
Sörnmo, L ;
Johansson, R ;
Sandhall, L ;
Sunemark, M ;
Smideberg, B ;
Olsson, SB .
CARDIOVASCULAR RESEARCH, 1998, 38 (01) :69-81
[4]   Mechanisms of wave fractionation at boundaries of high-frequency excitation in the posterior left atrium of the isolated sheep heart during atrial fibrillation [J].
Kalifa, JM ;
Tanaka, K ;
Zaitsev, AV ;
Warren, M ;
Vaidyanathan, R ;
Auerbach, D ;
Pandit, S ;
Vikstrom, KL ;
Ploutz-Snyder, R ;
Talkachou, A ;
Atienza, F ;
Guiraudon, G ;
Jalife, J ;
Berenfeld, O .
CIRCULATION, 2006, 113 (05) :626-633
[5]  
Konings KTS, 1997, CIRCULATION, V95, P1231
[6]   HIGH-DENSITY MAPPING OF ELECTRICALLY-INDUCED ATRIAL-FIBRILLATION IN HUMANS [J].
KONINGS, KTS ;
KIRCHHOF, CJHJ ;
SMEETS, JRLM ;
WELLENS, HJJ ;
PENN, OC ;
ALLESSIE, MA .
CIRCULATION, 1994, 89 (04) :1665-1680
[7]   Presence of left-to-right atrial frequency gradient in paroxysmal but not persistent atrial fibrillation in humans [J].
Lazar, S ;
Dixit, S ;
Marchlinski, FE ;
Callans, DJ ;
Gerstenfeld, EP .
CIRCULATION, 2004, 110 (20) :3181-3186
[8]   Effects of two different catheter ablation techniques on spectral characteristics of atrial fibrillation [J].
Lemola, Kristina ;
Ting, Michael ;
Gupta, Priya ;
Anker, Jeffrey N. ;
Chugh, Aman ;
Good, Eric ;
Reich, Scott ;
Tschopp, David ;
Igic, Petar ;
Elmouchi, Darryl ;
Jongnarangsin, Krit ;
Bogun, Frank ;
Pelosi, Frank, Jr. ;
Morady, Fred ;
Oral, Hakan .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (02) :340-348
[9]   Frequency analysis in different types of paroxysmal atrial fibrillation [J].
Lin, YJ ;
Tai, CT ;
Kao, T ;
Tso, HW ;
Higa, S ;
Tsao, HM ;
Chang, SL ;
Hsieh, MH ;
Chen, SA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (07) :1401-1407
[10]   Progressive remodeling of the atrial substrate - A novel finding from consecutive voltage mapping in patients with recurrence of atrial fibrillation after catheter ablation [J].
Lo, Li-Wei ;
Tai, Ching-Tai ;
Lin, Yenn-Jiang ;
Chang, Shih-Lin ;
Wongcharoen, Wanwarang ;
Chang, Sheng-Hsiung ;
Hsieh, Ming-Hsiung ;
Tuan, Ta-Chuan ;
Udyavar, Ameya R. ;
Chen, Yi-Jen ;
Tsao, Hsuan-Ming ;
Chen, Shih-Ann .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (03) :258-265