Immunosensor for detection of Legionella pneumophila based on imaging ellipsometry

被引:14
作者
Bae, YM [1 ]
Oh, BK [1 ]
Lee, WC [1 ]
Lee, WH [1 ]
Choi, JW [1 ]
机构
[1] Sogang Univ, Dept Chem & Biomol Engn, Seoul 121742, South Korea
来源
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS | 2004年 / 24卷 / 1-2期
关键词
immunosensor; imaging ellipsometry; Legionella pneumophila; self-assembly;
D O I
10.1016/j.msec.2003.09.049
中图分类号
T [工业技术];
学科分类号
08 [工学];
摘要
An immunosensor based on imaging ellipsometry as detection method was developed for the detection of Legionella pneumophila. Sequential depositions of 11-mercaptoundecanoic acid (11-MUA), protein G, and the monoclonal antibody against L. pneumophila (Mab) on gold surface were confirmed via surface plasmon resonance (SPR). Also, the cross-sensitivity of the Mab against several pathogens including Escherichia coli O157:H7, Salmonella spp. and Yersinia spp. was investigated using the SPR. The immunosensor for detection of L. pneumophila was fabricated by injecting protein G solution using the micro-arrayer and immobilizing the Mab on it. Imaging ellipsometry was used for detection of binding of L. pneumophila to the Mab layer. Ellipsometric images of the protein spots on the substrate according to binding of L. pneumophila with various concentrations were acquired, and the mean optical intensities of them were calculated using the image process software. The low detection limit was about 10(3) CFU/ml. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:61 / 64
页数:4
相关论文
共 14 条
[1]
[Anonymous], 1993, IMMUNOMETHODS
[2]
OFF-NULL ELLIPSOMETRY REVISITED - BASIC CONSIDERATIONS FOR MEASURING SURFACE CONCENTRATIONS AT SOLID LIQUID INTERFACES [J].
ARWIN, H ;
WELINKLINTSTROM, S ;
JANSSON, R .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1993, 156 (02) :377-382
[3]
BAE YM, 2003, UNPUB ANAL CHEM
[4]
Choi H.G., 2001, BIOTECHNOL BIOPROC E, V6, P183
[5]
CHOI JW, 1999, BIOTECHNOL BIOPROCES, V4, P138
[6]
COLBOURNE JS, 1998, WATER SCI TECHNOL, V20, P11
[7]
PONTIAC FEVER - EPIDEMIC OF UNKNOWN ETIOLOGY IN A HEALTH DEPARTMENT .1. CLINICAL AND EPIDEMIOLOGIC ASPECTS [J].
GLICK, TH ;
GREGG, MB ;
BERMAN, B ;
MALLISON, G ;
RHODES, WW ;
KASSANOFF, I .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1978, 107 (02) :149-160
[8]
Description of a single modular optical setup for ellipsometry, surface plasmons, waveguide modes, and their corresponding imaging techniques including Brewster angle microscopy [J].
Harke, M ;
Teppner, R ;
Schulz, O ;
Motschmann, H ;
Orendi, H .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (08) :3130-3134
[9]
A BIOSENSOR CONCEPT BASED ON IMAGING ELLIPSOMETRY FOR VISUALIZATION OF BIOMOLECULAR INTERACTIONS [J].
JIN, G ;
TENGVALL, P ;
LUNDSTROM, I ;
ARWIN, H .
ANALYTICAL BIOCHEMISTRY, 1995, 232 (01) :69-72
[10]
Noort D. V., 2000, MEAS SCI TECHNOL, V11, P801