Flow-injection analysis of two fluoquinolones by the sensitizing effect of terbium(III) on chemiluminescence of the potassium permanganate-sodium sulfite system

被引:60
作者
Yi, L
Zhao, HC [1 ]
Chen, S
Jin, LP
Zheng, DD
Wu, ZL
机构
[1] Beijing Normal Univ, Dept Chem, Beijing 100875, Peoples R China
[2] Beijing Normal Univ, Analyt & Testing Ctr, Beijing 100875, Peoples R China
基金
中国国家自然科学基金;
关键词
chemiluminescence; enoxacin; ofloxacin; terbium(III);
D O I
10.1016/S0039-9140(03)00301-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, rapid and sensitive method for the determination of two fluoquinolones (FQs), enoxacin (ENX) and ofloxacin (OFLX) is described by using flow injection analysis with potassium permanganate-sodium sulfite chemiluminescence detection. The calibration graphs for ENX and OFLX are linear in the range of 8.0 x 10(-10) 1.0 X 10(-5) and 1.0 X 10(-9)1.0 X 10(-6) mol l(-1), respectively. The 3sigma limits of detection are 2.4 x 10(-10) mol l(-1) for ENX and 5.6 x 10(-10) mol l(-1) for OFLX. The method is applied satisfactorily to the determination of the two FQs in dosage form and urine sample. The possible mechanism is also proposed. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:403 / 409
页数:7
相关论文
共 25 条
[1]   DETERMINATION OF OFLOXACIN IN PHARMACEUTICAL FORMS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND DERIVATIVE UV-SPECTROPHOTOMETRY [J].
CARLUCCI, G ;
MAZZEO, P ;
FANTOZZI, T .
ANALYTICAL LETTERS, 1993, 26 (10) :2193-2201
[2]  
DE W, 1979, J AM CHEM SOC, V101, P334
[3]   EUROPIUM AND TERBIUM CHELATORS AS CANDIDATE SUBSTRATES FOR ENZYME-LABELED TIME-RESOLVED FLUOROMETRIC IMMUNOASSAYS [J].
DIAMANDIS, EP .
ANALYST, 1992, 117 (12) :1879-1884
[4]   Chemiluminescence of systems containing lanthanide ions [J].
Elbanowski, M ;
Makowska, B ;
Staninski, K ;
Kaczmarek, M .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2000, 130 (2-3) :75-81
[5]   A VALIDATED ION-PAIRING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF ENOXACIN AND ITS METABOLITE OXO-ENOXACIN IN PLASMA AND URINE [J].
GOEBEL, KJ ;
STOLZ, H ;
EHRET, I ;
NUSSBAUM, W .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1991, 14 (04) :733-751
[6]   Analytical applications of acidic potassium permanganate as a chemiluminescence reagent [J].
Hindson, BJ ;
Barnett, NW .
ANALYTICA CHIMICA ACTA, 2001, 445 (01) :1-19
[7]  
*HLTH DEP PR CHIN, WS333X26794 HLTH DEP
[8]  
*HLTH DEP PR CHIN, WS082X6792 HLTH DEP
[9]   Chemiluminescence of sulfite based on auto-oxidation sensitized by rhodamine 6G [J].
Huang, YM ;
Zhang, C ;
Zhang, XR ;
Zhang, ZJ .
ANALYTICA CHIMICA ACTA, 1999, 391 (01) :95-100
[10]   Chemiluminescence analysis of menadione sodium bisulfite and analgin in pharmaceutical preparations and biological fluids [J].
Huang, YM ;
Zhang, C ;
Zhang, XR ;
Zhang, ZJ .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 21 (04) :817-825