Comparison of volume control and pressure control ventilation: Is flow waveform the differences

被引:70
作者
Davis, K [1 ]
Branson, RD [1 ]
Campbell, RS [1 ]
Porembka, DT [1 ]
机构
[1] UNIV CINCINNATI,MED CTR,DEPT ANESTHESIA,CINCINNATI,OH 45267
关键词
D O I
10.1097/00005373-199611000-00007
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To examine the hypothesis that a decelerating inspiratory flow waveform is responsible for improvements in gas exchange during pressure control ventilation for acute lung injury. Design: Prospective, controlled, crossover study. Measurements and Main Results: Twenty-five patients with acute lung injury requiring mechanical ventilation with a positive-end expiratory pressure greater than or equal to 10 cm H2O, ventilator frequency of greater than or equal to 8 bpm, inspired oxygen concentration of greater than or equal to 0.50, peak inspiratory pressure greater than or equal to 40 cm H2O, and requiring sedation and paralysis were studied, Patients were ventilated at a tidal volume of 10 mL/kg, respiratory frequency was set to maintain a pH > 7.30 and Paco(2) < 50 mm Hg, and positive end-expiratory pressure (PEEP) set to maintain Pao(2) > 70 mm Hg or Sao(2) > 93% with an Fio(2) less than or equal to 0.50. In random sequence, ventilator mode was changed from volume control with a square flow waveform, pressure control ventilation with a decelerating non waveform, or volume control ventilation with a decelerating flow waveform. Tidal volume, minute ventilation and airway pressures were continuously measured at the proximal airway. After 2 hours of ventilation in each mode, arterial and mixed venous blood gases were drawn and cardiac output determined by thermodilution, Dead space to tidal volume ratio was determined from mixed expired gas concentrations and Paco(2). During volume control ventilation with a square flow waveform, Pao(2) was decreased (75 +/- 11 mm Hg vs. 85 +/- 9 mm Hg and 89 +/- 12 mm Hg), p < 0.05, and peak inspiratory, pressure was increased (50 +/- 9 cm H2O vs. 42 +/- 7 cm H2O and 39 +/- 9 cm H2O) p < 0.05 compared to volume control with a decelerating flow waveform and pressure control ventilation. Mean airway pressure was also lower with volume control with a square flow waveform (17 +/- 4 cm H2O vs. 20 +/- 4 cm H2O and 21 +/- 3 cm H2O) compared to volume control with a decelerating flow waveform and pressure control ventilation. There were no differences in hemodynamic parameters. Conclusions: Both pressure control ventilation and volume control ventilation with a decelerating flow waveform provided better oxygenation at a lower peak inspiratory pressure and higher mean airway pressure compared to volume control ventilation with a square flow waveform. The results of our study suggest that the reported advantages of pressure control ventilation over volume control ventilation with a square flow waveform can be accomplished with volume control ventilation with a decelerating now waveform.
引用
收藏
页码:808 / 814
页数:7
相关论文
共 31 条
[1]   CARDIORESPIRATORY EFFECTS OF PRESSURE CONTROLLED VENTILATION IN SEVERE RESPIRATORY-FAILURE [J].
ABRAHAM, E ;
YOSHIHARA, G .
CHEST, 1990, 98 (06) :1445-1449
[2]   EFFECTS OF VARIATIONS OF INSPIRATORY FLOW WAVEFORM ON CARDIORESPIRATORY FUNCTION DURING CONTROLLED VENTILATION IN NORMOVOLAEMIC, HYPOVOLAEMIC AND HYPERVOLAEMIC DOGS [J].
ADAMS, AP ;
ECONOMIDES, AP ;
FINLAY, WEI ;
SYKES, MK .
BRITISH JOURNAL OF ANAESTHESIA, 1970, 42 (10) :818-+
[3]  
ALSAADY N, 1985, INTENS CARE MED, V11, P68
[4]   PRESSURE-CONTROLLED, INVERSE RATIO VENTILATION THAT AVOIDS AIR TRAPPING IN THE ADULT-RESPIRATORY-DISTRESS-SYNDROME [J].
ARMSTRONG, BW ;
MACINTYRE, NR .
CRITICAL CARE MEDICINE, 1995, 23 (02) :279-285
[5]   EFFECTS OF VARYING INSPIRATORY FLOW WAVEFORM AND TIME IN INTERMITTENT POSITIVE PRESSURE VENTILATION .2. VARIOUS PHYSIOLOGICAL VARIABLES [J].
BAKER, AB ;
COLLISS, JE ;
COWIE, RW .
BRITISH JOURNAL OF ANAESTHESIA, 1977, 49 (12) :1221-1234
[6]  
BERGMAN NA, 1969, AM REV RESPIR DIS, V100, P518
[8]   EFFECTS OF VARYING RESPIRATORY WAVEFORMS ON GAS EXCHANGE [J].
BERGMAN, NA .
ANESTHESIOLOGY, 1967, 28 (02) :390-&
[9]  
CHATBURN RL, 1990, HDB RESP CARE, P59
[10]   OPTIMAL FLOW PATTERN FOR MECHANICAL VENTILATION OF LUNGS .2. EFFECT OF A SINE VERSUS SQUARE-WAVE FLOW PATTERN WITH AND WITHOUT AN END-INSPIRATORY PAUSE ON PATIENTS [J].
DAMMANN, JF ;
MCASLAN, TC ;
MAFFEO, CJ .
CRITICAL CARE MEDICINE, 1978, 6 (05) :293-310