Scattered radiation during fixation of hip fractures - Is distance alone enough protection?

被引:40
作者
Alonso, JA
Shaw, DL
Maxwell, A
McGill, GP
Hart, GC
机构
[1] Bradford Royal Infirm, Dept Orthopaed & Trauma Surg, Bradford BD9 8RJ, W Yorkshire, England
[2] Bradford Royal Infirm, Dept Med Phys, Bradford BD9 8RJ, W Yorkshire, England
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2001年 / 83B卷 / 06期
关键词
D O I
10.1302/0301-620X.83B6.11065
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We measured the scattered radiation received by theatre staff, using high-sensitivity electronic personal dosimeters, during fixation of extracapsular fractures of the neck of the femur by dynamic hip screw. The dose received was correlated with that received by the patient, and the distance from the source of radiation. A scintillation detector and a water-filled model were used to define a map of the dose rate of scattered radiation in a standard operating theatre during surgery. Beyond two metres from the source of radiation, the scattered dose received was consistently low, while within the operating distance that received by staff was significant for both lateral and posteroanterior (PA) projections. The routine use of lead aprons outside the 2 m zone may be unnecessary. Within that zone it is recommended that lead aprons be worn and that thyroid shields are available for the surgeon and nursing assistants.
引用
收藏
页码:815 / 818
页数:4
相关论文
共 18 条
[1]
Is occupationally induced exposure to radiation a risk factor for thyroid nodule formation? [J].
Antonelli, A ;
Silvano, G ;
Gambuzza, C ;
Bianchi, F ;
Tana, L ;
Baschieri, L .
ARCHIVES OF ENVIRONMENTAL HEALTH, 1996, 51 (03) :177-180
[2]
AN ASSESSMENT OF THE RADIATION-DOSE RECEIVED BY STAFF USING FLUOROSCOPIC EQUIPMENT [J].
FAULKNER, K ;
MOORES, BM .
BRITISH JOURNAL OF RADIOLOGY, 1982, 55 (652) :272-276
[3]
Ionising radiation during internal fixation of extracapsular neck of femur fractures [J].
Giannoudis, PV ;
McGuigan, J ;
Shaw, DL .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1998, 29 (06) :469-472
[4]
Manipulation under anaesthetic of children's fractures: Use of the image intensifier reduces radiation exposure to patients and theatre personnel [J].
Keenan, WNW ;
Woodward, AF ;
Price, D ;
Eckloff, K ;
Richards, J ;
Powell, J ;
Shanahan, S .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1996, 16 (02) :183-186
[5]
Occupational x-ray exposure of anaesthetists [J].
McGowan, C ;
Heaton, B ;
Stephenson, RN .
BRITISH JOURNAL OF ANAESTHESIA, 1996, 76 (06) :868-869
[6]
Radiation exposure to the orthopaedic surgical team during fluoroscopy: "How far away is far enough?" [J].
Mehlman, CT ;
DiPasquale, TG .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (06) :392-398
[7]
Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing [J].
Muller, LP ;
Suffner, J ;
Wenda, K ;
Mohr, W ;
Rommens, PM .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1998, 29 (06) :461-468
[8]
ORourke PJ, 1996, J ROY COLL SURG EDIN, V41, P40
[9]
EXPOSURE OF THE ORTHOPEDIC SURGEON TO RADIATION [J].
SANDERS, R ;
KOVAL, KJ ;
DIPASQUALE, T ;
SCHMELLING, G ;
STENZLER, S ;
ROSS, E .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (03) :326-330
[10]
X-ray-induced DNA double-strand breaks in human sperm [J].
Singh, NP ;
Stephens, RE .
MUTAGENESIS, 1998, 13 (01) :75-79