Experimental study and modeling of polydimethylsiloxane peristaltic micropumps

被引:51
作者
Goulpeau, J
Trouchet, D
Ajdari, A
Tabeling, P
机构
[1] ESPCI, CNRS, UMR 7083, MMN, F-75005 Paris, France
[2] Bertin Technol, St Quentin en Yvelines, France
关键词
D O I
10.1063/1.1947893
中图分类号
O59 [应用物理学];
学科分类号
摘要
We present here an experimental study of three-valve peristaltic micropumps fabricated using polydimethylsiloxane multilayer soft lithography, along with a simple model representing their behavior. Variations of the generated flow rate with peristaltic cycle frequencies, design parameters, actuation pressures, and fluid viscosities are analyzed experimentally for a set of ten micropumps. The largest flow rates are obtained for particular "optimal" basic parameters (actuation pressures and cycle frequencies) that depend on design features. A single-valve model, based on nonlinear equivalent electrical circuits, is numerically and analytically solved in relevant cases, leading to qualitative and quantitative agreements with experiments. From this theoretical study, useful predictive rules are deduced for pump design. The maximum flow rate we could achieve is 7.5 mu L/min, one order-of-magnitude improvement compared to the highest level reported for this particular type of micropump. The design of the actuation system-including both internal and external micropump elements-was found crucial to achieving high flow rates. (c) 2005 American Institute of Physics.
引用
收藏
页数:9
相关论文
共 16 条
[1]   A two-stage discrete peristaltic micropump [J].
Berg, JM ;
Anderson, R ;
Anaya, M ;
Lahlouh, B ;
Holtz, M ;
Dallas, T .
SENSORS AND ACTUATORS A-PHYSICAL, 2003, 104 (01) :6-10
[2]   Microchip-based purification of DNA from biological samples [J].
Breadmore, MC ;
Wolfe, KA ;
Arcibal, IG ;
Leung, WK ;
Dickson, D ;
Giordano, BC ;
Power, ME ;
Ferrance, JP ;
Feldman, SH ;
Norris, PM ;
Landers, JP .
ANALYTICAL CHEMISTRY, 2003, 75 (08) :1880-1886
[3]  
BRUNET E, 2004, P MUTAS2004, P545
[4]  
EDDINGTON DT, 2003, UNPUB P MUTAS2003, P1089
[5]  
Gascoyne PRC, 2002, ELECTROPHORESIS, V23, P1973, DOI 10.1002/1522-2683(200207)23:13<1973::AID-ELPS1973>3.0.CO
[6]  
2-1
[7]   Monolithic membrane valves and diaphragm pumps for practical large-scale integration into glass microfluidic devices [J].
Grover, WH ;
Skelley, AM ;
Liu, CN ;
Lagally, ET ;
Mathies, RA .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 89 (03) :315-323
[8]   A robust and scalable microfluidic metering method that allows protein crystal growth by free interface diffusion [J].
Hansen, CL ;
Skordalakes, E ;
Berger, JM ;
Quake, SR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2002, 99 (26) :16531-16536
[9]   A nanoliter-scale nucleic acid processor with parallel architecture [J].
Hong, JW ;
Studer, V ;
Hang, G ;
Anderson, WF ;
Quake, SR .
NATURE BIOTECHNOLOGY, 2004, 22 (04) :435-439
[10]   Solving the "world-to-chip" interface problem with a microfluidic matrix [J].
Liu, J ;
Hansen, C ;
Quake, SR .
ANALYTICAL CHEMISTRY, 2003, 75 (18) :4718-4723