Synthesis and application of chloromethylated polystyrene modified with 1-phenyl-1,2-propanedione-2-oxime thiosemicarbazone (PPDOT) as a new sorbent for the on-line preconcentration and determination of copper in water, soil, and food samples by FAAS

被引:39
作者
Chamjangali, Mansour Arab [1 ]
Bagherian, Ghadamali [1 ]
Mokhlesian, Ali [1 ]
Bahramian, Bahram [1 ]
机构
[1] Shahrood Univ Technol, Coll Chem, Shahrood, Iran
关键词
Atomic absorption spectrometry; On-line preconcentration; Polystyrene; PPDOT; Copper(II); ATOMIC-ABSORPTION-SPECTROMETRY; SOLID-PHASE EXTRACTION; COMPLEXING AGENT; TRACE AMOUNTS; SCHIFF-BASE; CADMIUM; SYSTEM; LEAD; SEPARATION; ENRICHMENT;
D O I
10.1016/j.jhazmat.2011.06.093
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper, we report a simple and sensitive on-line solid phase extraction system for the preconcentration and determination of Cu(II) by flame atomic absorption spectrometry (FAAS). This method is based upon the on-line retention of copper at pH 5.0 on a minicolumn packed with chloromethylated polystyrene modified by 1-phenyl-1,2-propanedione-2-oxime thiosemicarbazone (PPDOT) as a new solid-phase extraction (SPE) sorbent. The retained Cu(II) ions were eluted with 1.0 M HNO(3). and transported directly to FAAS for determination. Several chemical and flow variables were studied and optimized for a quantitative preconcentration and determination of copper(II). At the optimized conditions, for preconcentration of 10.0 mL of a sample solution, a linear calibration graph was obtained over the concentration range of 3.00-120.0 mu g L(-1) for Cu(ll). The limit of detection (3 sigma), limit of quantification (10 sigma), and enrichment factor are 0.56 mu g L(-1), 2.0 mu g L(-1) and 41, respectively. The relative standard deviation (n = 6) at 20 mu g L(-1) of Cu(II) is 2.0%. This method could be applied for determination of trace amounts of Cu(II) in water, soil, and food samples with satisfactory results. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1641 / 1649
页数:9
相关论文
共 50 条
[1]   Flame atomic absorption spectrometry determination of trace amounts of copper after separation and preconcentration onto TDMBAC-treated analcime pyrocatechol-immobilized [J].
Afzali, D. ;
Mostafavi, A. ;
Taher, M. A. ;
Moradian, A. .
TALANTA, 2007, 71 (02) :971-975
[2]   1,10-phenanthroline as a complexing agent for on-line sorbent extraction preconcentration for flow injection-flame atomic absorption spectrometry [J].
Ali, A ;
Yin, XF ;
Shen, H ;
Ye, YX ;
Gu, X .
ANALYTICA CHIMICA ACTA, 1999, 392 (2-3) :283-289
[3]  
Ali A, 2000, LAB ROBOTICS AUTOMAT, V12, P97, DOI 10.1002/(SICI)1098-2728(2000)12:2<97::AID-LRA9>3.0.CO
[4]  
2-A
[5]  
[Anonymous], 2004, TOXICOLOGICAL PROFIL
[6]  
[Anonymous], 1995, Standard methods for the examination of water and wastewater, V19th
[7]   On-line preconcentration and determination of copper, lead and chromium(VI) using unloaded polyurethane foam packed column by flame atomic absorption spectrometry in natural waters and biological samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
TALANTA, 2002, 58 (05) :831-840
[8]   Evaluation of polychlorotrifluoroethylene as sorbent material for on-line solid phase extraction systems: Determination of copper and lead by flame atomic absorption spectrometry in water samples [J].
Anthemidis, Aristidis N. ;
Ioannou, Kallirroy-Ioanna G. .
ANALYTICA CHIMICA ACTA, 2006, 575 (01) :126-132
[9]  
Ashwood E.R., 1999, TIETS TXB CLIN CHEM
[10]   On-line preconcentration of copper as its pyrocatechol violet complex on Chromosorb 105 for flame atomic absorption spectrometric determinations [J].
Buke, Berrin ;
Divrikli, Umit ;
Soylak, Mustafa ;
Elci, Latif .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 163 (2-3) :1298-1302