Determination of barbiturates by solid phase microextraction and capillary electrophoresis

被引:81
作者
Li, S [1 ]
Weber, SG [1 ]
机构
[1] UNIV PITTSBURGH,DEPT CHEM,PITTSBURGH,PA 15260
关键词
D O I
10.1021/ac960790o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The solid phase microextraction device is based on plasticized poly(vinyl chloride) (PVC) as an extraction solvent, which is coated on a primed steel rod. The plasticizer is a phosphate triester. A simple device for back-extraction of analytes into a few microliters of back-extraction solution is described. A Tenon tube, with an inside diameter just larger than the PVC-coated extraction rod, is terminated at one end by a syringe. A few microliters of back-extraction solution is placed into the open end of the tube. Because the Tenon does not wet, the drop remains together. After exposure to sample, the PVC-coated extraction rod containing the analytes is inserted into the back-extraction solution-containing tube. The aqueous back-extraction solvent spreads out in the narrow annular space thus formed. After a suitable period, the rod is removed, and the droplet re-forms. It can be ejected into a sample vial with the syringe. The device has been used in a CE-based determination of barbiturates. Extraction, back-extraction, and separation of 10 barbiturates takes less than 30 min. Extraction and preconcentration of benzoates is also briefly considered.
引用
收藏
页码:1217 / 1222
页数:6
相关论文
共 26 条
[1]  
AICAZA M, 1993, ANAL CHEM, V65, pA525
[2]   OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION CONDITIONS FOR DETERMINATION OF PHENOLS [J].
BUCHHOLZ, KD ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :160-167
[3]  
CAI J, 1991, J LIQ CHROMATOGR, V559, P505
[4]   SOLID-PHASE MICROEXTRACTION COUPLED TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CHEN, J ;
PAWLISZYN, JB .
ANALYTICAL CHEMISTRY, 1995, 67 (15) :2530-2533
[5]   DETERMINATION OF PHENOLS IN SEA-WATER BY LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION AFTER ENRICHMENT BY USING SOLID-PHASE EXTRACTION CARTRIDGES AND DISKS [J].
GALCERAN, MT ;
JAUREGUI, O .
ANALYTICA CHIMICA ACTA, 1995, 304 (01) :75-84
[6]   DEWETTING EFFECTS ON POLYMER-COATED SURFACE-ACOUSTIC-WAVE VAPOR SENSORS [J].
GRATE, JW ;
MCGILL, RA .
ANALYTICAL CHEMISTRY, 1995, 67 (21) :4015-4019
[7]   VIBRATIONAL SPECTROSCOPIC STUDIES OF MOLECULAR ASSOCIATIONS BY LOCAL-ANESTHETICS [J].
GUERIN, M ;
DUMAS, JM ;
SANDORFY, C .
CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1980, 58 (19) :2080-2088
[8]   FAST, HIGH-RESOLUTION (CAPILLARY) ELECTROPHORESIS IN BUFFERS DESIGNED FOR HIGH-FIELD STRENGTHS [J].
HJERTEN, S ;
VALTCHEVA, L ;
ELENBRING, K ;
LIAO, JL .
ELECTROPHORESIS, 1995, 16 (04) :584-594
[9]   USE OF PARTICLE-LOADED MEMBRANES TO EXTRACT STEROIDS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSES IMPROVED ANALYTE STABILITY AND DETECTION [J].
LENSMEYER, GL ;
ONSAGER, C ;
CARLSON, IH ;
WIEBE, DA .
JOURNAL OF CHROMATOGRAPHY A, 1995, 691 (1-2) :239-246
[10]   Dual-sorption model of water uptake in poly(vinyl chloride)-based ion-selective membranes: Experimental water concentration and transport parameters [J].
Li, Z ;
Li, XZ ;
Petrovic, S ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1996, 68 (10) :1717-1725