Ambulatory measurement of the QKD interval normalized to heart rate and systolic blood pressure to assess arterial distensibility -: value of QKD100-60

被引:18
作者
Gosse, P [1 ]
Bemurat, L [1 ]
Mas, D [1 ]
Lemetayer, P [1 ]
Clementy, J [1 ]
机构
[1] Hop St Andre, F-33075 Bordeaux, France
关键词
arterial distensibility; QKD; ambulatory measurement of blood pressure;
D O I
10.1097/00126097-200104000-00004
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background Reduced distensibility of large arteries plays an important role in cardiovascular risk. Determination of the QKD interval during the ambulatory measurement of blood pressure enables calculation of an index of arterial distensibility, This index, the QKD(100-60) is the theoretical value of QKD at systolic blood pressure of 100 mmHg and heart rate of 60 bpm obtained from the linear bivariate relationship linking QKD, systolic blood pressure and heart rate on a hundred successive values measured over 24 h. This study was designed to examine the relationship between QKD and QKD(100-60) on heart rate and systolic function of the left ventricle, the two parameters governing the pre-ejection time which is part of the QKD interval. Methods and results In a population of 203 untreated hypertensive patients having benefited from an ambulatory measurement of blood pressure over 24 h with QKD monitoring and an M-mode echocardiographic recording of the left ventricle, we found that although mean QKD was linked to heart rate and systolic function of the left ventricle, QKD(100-60) was not. It fell significantly with age, and to a greater extent in the sustained hypertensives than in white-coat hypertensives, Conclusion QKD(100-60) constitutes an index of arterial distensibility independent of the pre-ejection time. As an adjunct to the ambulatory measurement of blood pressure, its determination is simple and completely automatic, thus eliminating observer bias. Blood Press Monit 6:85-89 (C) 2001 Lippincott Williams & Wilkins.
引用
收藏
页码:85 / 89
页数:5
相关论文
共 16 条
  • [1] PULSE-WAVE ARRIVAL TIME (QKD INTERVAL) IN NORMAL-CHILDREN
    BERCU, BB
    HAUPT, R
    JOHNSONBAUGH, R
    RODBARD, D
    [J]. JOURNAL OF PEDIATRICS, 1979, 95 (05) : 716 - 721
  • [2] The effect of age on vascular compliance in man: which are the appropriate measures?
    Bulpitt, CJ
    Cameron, JD
    Rajkumar, C
    Armstrong, S
    Connor, M
    Joshi, J
    Lyons, D
    Moioli, O
    Nihoyannopoulos, P
    [J]. JOURNAL OF HUMAN HYPERTENSION, 1999, 13 (11) : 753 - 758
  • [3] Ambulatory measurement of the timing of Korotkoff sounds in a group of normal subjects - Influence of age and height
    Gosse, P
    Jullien, V
    Lemetayer, P
    Jarnier, P
    Clementy, J
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 1999, 12 (02) : 231 - 235
  • [4] Prognostic value of ambulatory measurement of the timing of Korotkoff sounds in elderly hypertensives - A pilot study
    Gosse, P
    Gasparoux, P
    Ansoborlo, P
    Lemetayer, P
    Clementy, J
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 1997, 10 (05) : 552 - 557
  • [5] Gosse P, 1996, ARCH MAL COEUR VAISS, V89, P975
  • [6] Reduction in arterial distensibility in hypertensive patients as evaluated by ambulatory measurement of the QKD interval is correlated with concentric remodeling of the left ventricle
    Gosse, P
    Jullien, V
    Jarnier, P
    Lemetayer, P
    Clementy, J
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 1999, 12 (12) : 1252 - 1255
  • [7] ASSESSMENT OF ARTERIAL DISTENSIBILITY BY MONITORING THE TIMING OF KOROTKOFF SOUNDS
    GOSSE, P
    GUILLO, P
    ASCHER, G
    CLEMENTY, J
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 1994, 7 (03) : 228 - 233
  • [8] GOSSE P, 1991, MED HYG, V49, P3288
  • [9] HASEGAWA M, 1976, J THORAC CARDIOV SUR, V72, P62
  • [10] Blood pressure measuring devices: recommendations of the European Society of Hypertension
    O'Brien, E
    Waeber, B
    Parati, G
    Staessen, J
    Myers, MG
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2001, 322 (7285): : 531 - 536