Optimal choice for number of strands in a litz-wire transformer winding

被引:402
作者
Sullivan, CR [1 ]
机构
[1] Dartmouth Coll, Thayer Sch Engn, Hanover, NH 03755 USA
关键词
eddy currents; litz wire; magnet wire; power electronics; power transformers; proximity-effect losses; skin effect; transformer windings;
D O I
10.1109/63.750181
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The number and diameter of strands to minimize loss in a litz-wire transformer winding is determined, With fine stranding, the ac resistance factor can be decreased, but de resistance increases as a result of the space occupied by insulation. A power law to model insulation thickness is combined with standard analysis of proximity-effect losses to find the optimal stranding. Suboptimal choices under other constraints are also determined.
引用
收藏
页码:283 / 291
页数:9
相关论文
共 27 条
[1]  
Bartoli M, 1996, IEEE POWER ELECTRON, P1690, DOI 10.1109/PESC.1996.548808
[2]  
BRESLIN JG, 1997, 28 ANN IEEE POW EL S, V1, P655
[3]  
BUTTERWORTH S, 1926, WIRELESS ENG, V3, P309
[4]  
BUTTERWORTH S, 1926, WIRELESS ENG, V3, P203
[5]  
Carsten B., 1986, Technical Papers of the First International High Frequency Power Conversion 1986 Conference, P155
[6]  
COONROD NR, 1984, IEEE POW EL SPEC, P257
[7]  
DIXON LH, 1988, UNITODE SWITCHING RE
[8]   EFFECTS OF EDDY CURRENTS IN TRANSFORMER WINDINGS [J].
DOWELL, PL .
PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1966, 113 (08) :1387-&
[9]   IMPROVED ANALYTICAL MODELING OF CONDUCTIVE LOSSES IN MAGNETIC COMPONENTS [J].
FERREIRA, JA .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1994, 9 (01) :127-131
[10]   ANALYTICAL COMPUTATION OF AC RESISTANCE OF ROUND AND RECTANGULAR LITZ WIRE WINDINGS [J].
FERREIRA, JA .
IEE PROCEEDINGS-B ELECTRIC POWER APPLICATIONS, 1992, 139 (01) :21-25