Data explosion: the challenge of multidetector-row CT

被引:151
作者
Rubin, GD [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
关键词
multidetector-row CT; data explosion; 3D workstation;
D O I
10.1016/S0720-048X(00)00270-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The development of multi detector-row CT has brought many exciting advancements to clinical CT scanning. While multi detector-raw CT offers unparalleled speed of acquisition, spatial resolution, and anatomic coverage, a challenge presented by these advantages is the substantial increase on the number of reconstructed cross-sections that are rapidly created and in need of analysis. This manuscript discusses currently available alternative visualization techniques for the assessment of volumetric data acquired with multi detector-row CT. Although the current capabilities of 3-D workstations offer many possibilities for alternative analysis of MCDT data, substantial improvements both in automated processing, processing speed and user interface will be necessary to realize the vision of replacing the primary analysis of transverse reconstruction's with alternative analyses. The direction that same of these future developments might take are discussed. (C) 2000 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:74 / 80
页数:7
相关论文
共 29 条
  • [1] PULMONARY NODULES - EFFECT OF INCREASED DATA SAMPLING ON DETECTION WITH SPIRAL CT AND CONFIDENCE IN DIAGNOSIS
    BUCKLEY, JA
    SCOTT, WW
    SIEGELMAN, SS
    KUHLMAN, JE
    URBAN, BA
    BLUEMKE, DA
    FISHMAN, EK
    [J]. RADIOLOGY, 1995, 196 (02) : 395 - 400
  • [2] 3D SURFACE RENDERED MR IMAGES OF THE BRAIN AND ITS VASCULATURE
    CLINE, HE
    LORENSEN, WE
    SOUZA, SP
    JOLESZ, FA
    KIKINIS, R
    GERIG, G
    KENNEDY, TE
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (02) : 344 - 351
  • [3] Volume rendering
    Drebin, Robert A.
    Carpenter, Loren
    Hanrahan, Pat
    [J]. Computer Graphics (ACM), 1988, 22 (04): : 65 - 74
  • [4] Tracheobronchial tree: Three-dimensional spiral CT with bronchoscopic perspective
    Ferretti, GR
    Vining, DJ
    Knoplioch, J
    Coulomb, M
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (05) : 777 - 781
  • [5] VOLUMETRIC RENDERING TECHNIQUES - APPLICATIONS FOR 3-DIMENSIONAL IMAGING OF THE HIP
    FISHMAN, EK
    DREBIN, B
    MAGID, D
    SCOTT, WW
    NEY, DR
    BROOKER, AF
    RILEY, LH
    STVILLE, JA
    ZERHOUNI, EA
    SIEGELMAN, SS
    [J]. RADIOLOGY, 1987, 163 (03) : 737 - 738
  • [6] Colorectal polyp detection with CT colography: Two- versus three-dimensional techniques - Work in progress
    Hara, AK
    Johnson, CD
    Reed, JE
    Ehman, RL
    Ilstrup, DM
    [J]. RADIOLOGY, 1996, 200 (01) : 49 - 54
  • [7] Detection of colorectal polyps by computed tomographic colography: Feasibility of a novel technique
    Hara, AK
    Johnson, CD
    Reed, JE
    Ahlquist, DA
    Nelson, H
    Ehman, RL
    McCollough, CH
    Ilstrup, DM
    [J]. GASTROENTEROLOGY, 1996, 110 (01) : 284 - 290
  • [8] Three-dimensional CT: Real-time interactive volume rendering
    Johnson, PT
    Heath, DG
    Bliss, DF
    Cabral, B
    Fishman, EK
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (03) : 581 - 583
  • [9] MR ANGIOGRAPHY WITH TWO-DIMENSIONAL ACQUISITION AND 3-DIMENSIONAL DISPLAY - WORK IN PROGRESS
    KELLER, PJ
    DRAYER, BP
    FRAM, EK
    WILLIAMS, KD
    DUMOULIN, CL
    SOUZA, SP
    [J]. RADIOLOGY, 1989, 173 (02) : 527 - 532
  • [10] Thoracic aortic aneurysm and aortic dissection: New endoscopic mode for three-dimensional CT display of aorta
    Kimura, F
    Shen, Y
    Date, S
    Azemoto, S
    Mochizuki, T
    [J]. RADIOLOGY, 1996, 198 (02) : 573 - 578