摘要
OBJECTIVE. Our purpose was to assess the negative predictive value of imaging-guided abdominal biopsy results and correlate it with cytology classification, lesion size, needle gauge, and cancer history. MATERIALS AND METHODS. A retrospective study was performed of 100 patients with proven diagnoses who had undergone imaging-guided abdominal biopsies showing no cells that were malignant or suspicious for malignancy. Specimens were classified as normal or benign, nondiagnostic, or atypical. Negative predictive value was calculated for each cytologic category, lesion size, needle gauge, and cancer history. Logistic regression analysis was performed to allow us to identify predictors of false-negative results. RESULTS. Overall negative predictive value was 67%. Other negative predictive values were normal or benign result, 78%; nondiagnostic result, 66%; and atypical result, 29%. Negative predictive value was greater when the lesion was large (greater than or equal to 3 cm) (p =.031), Logistic regression analysis allowed us to predict a 9.3% chance of a false-negative result for a specimen of normal or benign cytology that was taken from a large lesion in a patient with no cancer history but an 87% chance of a false-negative when a specimen of atypical cytology was taken from a small (<3 cm) lesion in a patient with a cancer history. CONCLUSION. Imaging-guided abdominal biopsy specimens containing atypical cells should be viewed with caution. In patients without cancer, if a lesion is large and the specimen contains normal target organ or benign cells, the likelihood of a false-negative result may be low enough that imaging surveillance at appropriate intervals may be sufficient.
引用
收藏
页码:693 / 696
页数:4
相关论文
共 20 条
[1]   CT AND SONOGRAPHICALLY GUIDED NEEDLE-BIOPSY - CURRENT TECHNIQUES AND NEW INNOVATIONS [J].
CHARBONEAU, JW ;
READING, CC ;
WELCH, TJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (01) :1-10
[2]  
DAWSONSAUNDERS B, 1994, BASIC CLIN BIOSTATIS, P236
[3]  
DAWSONSAUNDERS B, 1994, BASIC CLIN BIOSTATIS, P144
[4]  
DAWSONSAUNDERS B, 1994, BASIC CLIN BIOSTATIS, P134
[5]  
DAWSONSAUNDERS B, 1994, BASIC CLIN BIOSTATIS, P211
[6]  
EDOUTE Y, 1992, AM J GASTROENTEROL, V87, P1138
[7]   DIAGNOSIS OF ABDOMINAL-MALIGNANCY BY RADIOLOGIC FINE-NEEDLE ASPIRATION BIOPSY [J].
FERRUCCI, JT ;
WITTENBERG, J ;
MUELLER, PR ;
SIMEONE, JF ;
HARBIN, WP ;
KIRKPATRICK, RH ;
TAFT, PD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1980, 134 (02) :323-330
[8]   GUIDED PERCUTANEOUS BIOPSY OF INTRAABDOMINAL LESIONS [J].
GAZELLE, GS ;
HAAGA, JR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (05) :929-935
[9]   FINE-NEEDLE ASPIRATION BIOPSY - PANCREATIC AND BILIARY TUMORS [J].
HALLCRAGGS, MA ;
LEES, WR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (02) :399-403
[10]  
LEES WR, 1985, CLIN RADIOL, V36, P517, DOI 10.1016/S0009-9260(85)80204-X