Efficiency of a portable indoor air cleaner in removing pollens and fungal spores

被引:46
作者
Cheng, YS
Lu, JC
Chen, TR
机构
[1] Lovelace Resp Res Inst, Albuquerque, NM 87185 USA
[2] Inst Microbiol & Epidemiol, Beijing, Peoples R China
[3] Natl Tsing Hua Univ, Hsinchu, Taiwan
关键词
D O I
10.1080/02786829808965554
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The purpose of this study was to determine the efficiency of a commercial air cleaner in removing pollens and fungal spores indoors. The effect of the air ventilation rate in a room on the removal efficiency was also investigated. The air cleaner consisted of a HEPA filtration unit and a fan operated at a flow rate of 404 m(3) per h. This system was tested in two adjacent but separate bedrooms on the second floor of a single-family home. The system was used in Room A to clean the air; Room B served as a control. The study was conducted during the summer and fall, and an evaporative cooling unit with duets to each room delivered outside air. The ventilation rate was controlled by adjusting the how rates of the evaporator with minor adjustment of the window opening to give similar ventilation rates in both rooms. At the beginning of the test, ventilation rates were measured using an SF6 tracer gas method, and ventilation was adjusted so that both rooms had similar air exchange rates. Then an air cleaner unit was turned on in Room A, and aerosol samples were collected every 2 h. Two identical Allergenco Biosamplers (Mark-3, Allergenco, San Antonio, TX) collected particles by impaction on a moving grass slide coated with silicon grease. The test Lasted for 24 h. Pollens and fungal spores on the collection substrates were identified and counted using an optical microscope. Particle concentrations were then estimated from the particle count and flow rate. At a high ventilation rate (2.8-3 h(-1)), the system helped to maintain a low concentration (10-20% of initial concentration) of pollen and spores; particle concentrations in Room B remained the same without the air cleaner. At a moderate ventilation rate (1-1.2 h(-1)), the filtration process helped to remove >80% of the particles in Room A,whereas in Room B, the concentrations were reduced to about 50% by sedimentation. At a low air exchange rate (<0.2 h(-1)), pollen and fungal spore concentrations in bath rooms decreased rapidly to <10% of initial values within 1 h, indicating sedimentation of large particles. The air cleaner helped the cleaning process by shortening the cleanup time. Our results suggest that this air cleaner is useful in filtering out pollens and spores, and it is more effective when doors and windows are closed, especially when there are no activities in the room. (C) 1998 American Association for Aerosol Research
引用
收藏
页码:92 / 101
页数:10
相关论文
共 12 条
  • [1] INCENSE SMOKE - CHARACTERIZATION AND DYNAMICS IN INDOOR ENVIRONMENTS
    CHENG, YS
    BECHTOLD, WE
    YU, CC
    HUNG, IF
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 1995, 23 (03) : 271 - 281
  • [2] TURBULENT DEPOSITION AND GRAVITATIONAL SEDIMENTATION OF AN AEROSOL IN A VESSEL OF ARBITRARY SHAPE
    CRUMP, JG
    SEINFELD, JH
    [J]. JOURNAL OF AEROSOL SCIENCE, 1981, 12 (05) : 405 - 415
  • [3] GRANT SMITH E., 1990, SAMPLING IDENTIFYING
  • [4] CONTROL OF INDOOR RADON DECAY PRODUCTS BY AIR TREATMENT DEVICES
    HINDS, WC
    RUDNICK, SN
    MAHER, EF
    FIRST, MW
    [J]. JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1983, 33 (02): : 134 - 136
  • [5] EFFICACY OF AIR CLEANING SYSTEMS IN CONTROLLING INDOOR RADON DECAY PRODUCTS
    LI, CS
    HOPKE, PK
    [J]. HEALTH PHYSICS, 1991, 61 (06): : 785 - 797
  • [6] EFFECTIVE REMOVAL OF AIRBORNE RN-222 DECAY PRODUCTS INSIDE BUILDINGS
    MAHER, EF
    RUDNICK, SN
    MOELLER, DW
    [J]. HEALTH PHYSICS, 1987, 53 (04): : 351 - 356
  • [7] RESIDENTIAL AIR EXCHANGE-RATES IN THE UNITED-STATES - EMPIRICAL AND ESTIMATED PARAMETRIC DISTRIBUTIONS BY SEASON AND CLIMATIC REGION
    MURRAY, DM
    BURMASTER, DE
    [J]. RISK ANALYSIS, 1995, 15 (04) : 459 - 465
  • [8] CONTROL OF RESPIRABLE PARTICLES IN INDOOR AIR WITH PORTABLE AIR CLEANERS
    OFFERMANN, FJ
    SEXTRO, RG
    FISK, WJ
    GRIMSRUD, DT
    NAZAROFF, WW
    NERO, AV
    REVZAN, KL
    YATER, J
    [J]. ATMOSPHERIC ENVIRONMENT, 1985, 19 (11) : 1761 - 1771
  • [9] EFFECT OF ULTRA-STOKESIAN DRAG AND PARTICLE INTERCEPTION ON IMPACTION CHARACTERISTICS
    RADER, DJ
    MARPLE, VA
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 1985, 4 (02) : 141 - 156
  • [10] RAJALA M, 1987, SCI TOTAL ENVIRON, V45, P493