Off-site evaluation of liver lesion detection by Gd-BOPTA-enhanced MR imaging

被引:19
作者
Gehl, HB
Bourne, M
Grazioli, L
Möller, A
Lodemann, KP
机构
[1] Med Univ Lubeck, Inst Diagnost Radiol, D-23538 Lubeck, Germany
[2] Univ Wales Hosp, Dept Radiol, Cardiff CF4 4XW, S Glam, Wales
[3] Univ Brescia, Spedali Civili, Dept Radiol, Brescia, Italy
[4] MEDIDATA GmbH, Constance, Germany
[5] BRACCO BYK GULDEN GmbH, Constance, Germany
关键词
liver imaging; CT; MRI; Gd-BOPTA;
D O I
10.1007/s003300000593
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The aim of this study was to determine the efficacy of Gd-BOPTA-enhanced MRI in liver lesion detection in comparison with unenhanced MRI and dynamic CT. The image sets of 148 of 151 patients enrolled in a multicenter German phase-III trial were evaluated by two independent radiologists unaffiliated with the investigating centers. Patients underwent a routine MRI protocol comprising T2- and T1-weighted spin-echo and T1-weighted gradient-echo (GE) sequences pre and 1 h post 0.1 mmol/kg Gd-BOPTA (Bracco-Byk Gulden, Konstanz, Germany). Additionally, a serial T1-weighted GE scan was performed after administration of the first half of the dose. All patients underwent dynamic contrast-enhanced CT. The evaluation was performed with regard to the number and size of lesions detected per patient by each modality or sequence. Furthermore, all pre CM and pre + post CM image sets were analyzed for number of lesions per patient. Both readers detected significantly more lesions in the contrast-enhanced image set compared with the unenhanced image set (32 and 39 %, respectively; p < 0.0001). While contrast-enhanced CT detected a similar number of lesions to unenhanced MRI, it was clearly inferior to contrast-enhanced MRI (reader 1: p = 0.0117; reader 2: p = 0.0225). Of the T1-weighted scans performed, the dynamic and late T1-weighted GE exams contributed most to the increased lesion detection rate (reader 1: p = 0.0007; reader 2: p = 0.0037). The size of the smallest lesion detected by means of MRI was significantly larger in the pre-CM image sets than in the pre + post CM image sets (reader 1: p = 0.001; reader 2: p < 0.0001). Gd-BOPTA-enhanced MRI detected significantly smaller lesions than contrast-enhanced CT (reader 1: p = 0.0117; reader 2: p = 0.0925). Gd-BOPTA-enhanced MR imaging improves liver lesion detection significantly over unenhanced MRI and dynamic CT.
引用
收藏
页码:187 / 192
页数:6
相关论文
共 20 条
[1]
Focal malignant hepatic lesions: MR imaging enhanced with gadolinium benzyloxypropionictetra-acetate (BOPTA) - Preliminary results of phase II clinical application [J].
Caudana, R ;
Morana, G ;
Pirovano, GP ;
Nicoli, N ;
Portuese, A ;
Spinazzi, A ;
DiRito, R ;
Pistolesi, GF .
RADIOLOGY, 1996, 199 (02) :513-520
[2]
SOLUBLE-TYPE HEPATOBILIARY CONTRAST AGENTS FOR MR IMAGING [J].
DEHAEN, C ;
GOZZINI, L .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (01) :179-186
[3]
DYNAMIC MR IMAGING OF THE LIVER WITH GD-DTPA - INITIAL CLINICAL-RESULTS [J].
EDELMAN, RR ;
SIEGEL, JB ;
SINGER, A ;
DUPUIS, K ;
LONGMAID, HE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (06) :1213-1219
[4]
Surgery for recurrent colon cancer: Strategies for identifying resectable recurrence and success rates after resection [J].
Goldberg, RM ;
Fleming, TR ;
Tangen, CM ;
Moertel, CG ;
Macdonald, JS ;
Haller, DG ;
Laurie, JA .
ANNALS OF INTERNAL MEDICINE, 1998, 129 (01) :27-+
[5]
Liver metastases: Improved detection with dynamic gadolinium-enhanced MR imaging? [J].
Hamm, B ;
Mahfouz, AE ;
Taupitz, M ;
Mitchell, DG ;
Nelson, R ;
Halpern, E ;
Speidel, A ;
Wolf, KJ ;
Saini, S .
RADIOLOGY, 1997, 202 (03) :677-682
[6]
Gadobenate dimeglumine (Gd-BOPTA) - An overview [J].
Kirchin, MA ;
Pirovano, GP ;
Spinazzi, A .
INVESTIGATIVE RADIOLOGY, 1998, 33 (11) :798-809
[7]
HYPERVASCULAR MALIGNANT LIVER-LESIONS - COMPARISON OF VARIOUS MR-IMAGING PULSE SEQUENCES AND DYNAMIC CT [J].
LARSON, RE ;
SEMELKA, RC ;
BAGLEY, AS ;
MOLINA, PL ;
BROWN, ED ;
LEE, JKT .
RADIOLOGY, 1994, 192 (02) :393-399
[8]
ABDOMINAL MR IMAGING - COMPARISON OF T2-WEIGHTED FAST AND CONVENTIONAL SPIN-ECHO, AND CONTRAST-ENHANCED FAST MULTIPLANAR SPOILED GRADIENT-RECALLED IMAGING [J].
LOW, RN ;
FRANCIS, IR ;
SIGETI, JS ;
FOO, TKF .
RADIOLOGY, 1993, 186 (03) :803-811
[9]
Maccioni F, 1997, Radiol Med, V93, P708
[10]
INTERIM RESULTS OF PHASE-II CLINICAL-TESTING OF GADOBENATE DIMEGLUMINE [J].
ROSATI, G ;
PIROVANO, G ;
SPINAZZI, A .
INVESTIGATIVE RADIOLOGY, 1994, 29 :S183-S185