Biodegradable self-reinforced poly-L/DL-lactide plates and screws in bimaxillary orthognathic surgery: short term skeletal stability and material related failures

被引:69
作者
Haers, PE [1 ]
Sailer, HF [1 ]
机构
[1] Univ Zurich Hosp, Dept Craniomaxillofacial Surg, CH-8091 Zurich, Switzerland
关键词
D O I
10.1016/S1010-5182(98)80069-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Biodegradable self-reinforced poly-L/DL-lactide plates and screws were used for osteosynthesis in 10 consecutive cases of bimaxillary procedures with simultaneous genioplasties, without postoperative rigid intermaxillary fixation. During surgery, data were gathered concerning failure of the osteosynthesis material. Clinical examination was carried out meekly until the sixth postoperative week, Cephalometric analysis of standardized cephalograms was performed to evaluate the short-term skeletal stability pattern, which was compared with similar reports in the Literature. Six weeks postoperatively, all jams were clinically stable and there was no clinical evidence of foreign body reactions. For the whole group (n=10), the mean maxillary advancement at point A was 2.9 mm with a mean postoperative relapse of 0.0mm, The mean advancement at point B was 2.8mm with a mean additional advancement postoperatively of 1.1 mm, The mean vertical surgical displacement at point A was directed inferiorly with a value of 1.8 mm and a relapse of -0.4mm, At point B the corresponding values were 1.9 mm and -0.4 mm, In the Angle Class III group (n=4), the mean advancement at A mas 5.9 mm with an additional postoperative advancement of 0.3 mm, In the Angle Class II group (n=6), mean advancement at point B was 4.0 mm, with an additional postoperative advancement of 1.1 mm. In the group with short face deformity (n=3), the mean inferior movement in ANS was 6.6 mm with a relapse of -0.2 mm, At Menton the vertical surgical movement was 13.0 mm with a relapse of -0.2 mm. None of the plates, which were bent at room temperature:, broke, The screw heads broke or had an insufficient fit in the bone in 12 of 305 (3.9%) screws. It can be concluded that the tested system of biodegradable self-reinforced poly-L/DL-lactide screws and plates has a small material-related failure rate, and that their application in orthognathic surgery leads to a predictable short-term skeletal stability pattern which is comparable to the 'gold standard' of titanium plates and screws.
引用
收藏
页码:363 / 372
页数:10
相关论文
共 27 条
[1]  
Bos R R, 1989, Dtsch Z Mund Kiefer Gesichtschir, V13, P422
[2]  
CUTRIGHT DE, 1971, J ORAL SURG, V29, P393
[3]   Resorbable fixation of Le fort I osteotomies [J].
Edwards, RC ;
Kiely, KD .
JOURNAL OF CRANIOFACIAL SURGERY, 1998, 9 (03) :210-214
[4]   Biodegradable polylactide plates and screws in orthognathic surgery: technical note [J].
Haers, PE ;
Suuronen, R ;
Lindqvist, C ;
Sailer, H .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1998, 26 (02) :87-91
[5]  
HAERS PE, 1996, SAEGESSER SPEZIELLE, V11, P21
[6]  
Hiranaka DK, 1987, INT J ADULT ORTHOD O, V4, P193
[7]   The stability of facial osteotomies .4. Maxillary and mandibular (with or without chin) advancement with rigid internal fixation [J].
Hoffman, GR ;
Moloney, FB .
AUSTRALIAN DENTAL JOURNAL, 1995, 40 (06) :365-371
[8]  
ILLI OE, 1991, HELV CHIR ACTA, V58, P123
[9]   Detection of titanium in human tissues after craniofacial surgery [J].
Jorgenson, DS ;
Mayer, MH ;
Ellenbogen, RG ;
Centeno, JA ;
Johnson, FB ;
Mullick, FG ;
Manson, PN .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 99 (04) :976-979
[10]   Skeletal stability following mandibular advancement and rigid fixation with polylactide biodegradable screws [J].
Kallela, I ;
Laine, P ;
Suuronen, R ;
Iizuka, T ;
Pirinen, S ;
Lindqvist, C .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1998, 27 (01) :3-8