Steady-state bioavailability of controlled-release oxycodone in normal subjects

被引:36
作者
Reder, RF
Oshlack, B
Miotto, JB
Benziger, DD
Kaiko, RF
机构
[1] Pharmaceutical and Clinical Research, Purdue Frederick Company, Norwalk, CT
[2] Medical Department, Purdue Frederick Company, Norwalk, CT 06850-3590
关键词
D O I
10.1016/S0149-2918(96)80182-2
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The steady-state bioavailability of a controlled-release (CR) oxycodone tablet was compared with that of an immediate release (IR) oxycodone solution in a randomized, analytically masked, multiple-dose, crossover study in 24 normal subjects. Each subject received either one 10-mg CR oxycodone tablet every 12 hours for 4 days or 5 mt of a 1-mg/1 mt IR oxycodone solution every 6 hours for 4 days. Steady state was achieved after approximately 1 day of dosing. The mean (+/-SD) maximum plasma oxycodone concentrations for CR oxycodone and IR oxycodone were 15.1 +/- 4.7 ng/mL and 15.6 +/- 4.4 ng/mL, respectively. The time to maximum concentration (T-max) was approximately twice as long for CR oxycodone (3.2 +/- 2.2 hours) as for IR oxycodone (1.4 +/- 0.7 hours) (P = 0.005). The area under the plasma concentration-time curve from 0 to 12 hours at steady state was 103.6 +/- 40.0 ng . h/mL for CR oxycodone and 99.0 +/- 35.8 ng . h/mL for IR oxycodone. Except for T-max, there were no significant differences in pharmacokinetic parameters between treatments. Approximately twice as many adverse experiences, several of longer duration than noted with CR oxycodone, were reported with IR oxycodone. The bioavailability of the CR tablet was equal to that of the IR solution; however, the rate of oxycodone absorption from the CR tablet was slower than that from the TR solution, as shown by the T-max value. The use of CR oxycodone will allow selection of the most clinically appropriate nonopioid analgesic, as well as independent titration and dosing, thereby enhancing therapeutic flexibility.
引用
收藏
页码:95 / 105
页数:11
相关论文
共 11 条
[1]  
BEAVER WT, 1978, J PHARMACOL EXP THER, V207, P101
[2]  
Gourlay G., 1994, PROG PAIN RES MANAG, V2, P631
[3]   CHRONOPHARMACOKINETIC VARIABILITY IN PLASMA MORPHINE CONCENTRATIONS FOLLOWING ORAL DOSES OF MORPHINE SOLUTION [J].
GOURLAY, GK ;
PLUMMER, JL ;
CHERRY, DA .
PAIN, 1995, 61 (03) :375-381
[4]  
HOUDE RW, 1974, ADV NEUROL, V4, P527
[5]   Pharmacokinetic-pharmacodynamic relationships of controlled-release oxycodone [J].
Kaiko, RF ;
Benziger, DP ;
Fitzmartin, RD ;
Burke, BE ;
Reder, RF ;
Goldenheim, PD .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1996, 59 (01) :52-61
[6]   MORPHINE AND OXYCODONE HYDROCHLORIDE IN THE MANAGEMENT OF CANCER PAIN [J].
KALSO, E ;
VAINIO, A .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1990, 47 (05) :639-646
[7]  
KANTOR TG, 1981, J CLIN PHARMACOL, V21, P1
[8]  
LECOUTURE PG, 13 ANN M AM PAIN SOC
[9]   SINGLE-DOSE AND STEADY-STATE PHARMACOKINETICS AND PHARMACODYNAMICS OF OXYCODONE IN PATIENTS WITH CANCER [J].
LEOW, KP ;
SMITH, MT ;
WILLIAMS, B ;
CRAMOND, T .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1992, 52 (05) :487-495
[10]   THE PHARMACOKINETICS AND METABOLISM OF OXYCODONE AFTER INTRAMUSCULAR AND ORAL-ADMINISTRATION TO HEALTHY-SUBJECTS [J].
POYHIA, R ;
SEPPALA, T ;
OLKKOLA, KT ;
KALSO, E .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1992, 33 (06) :617-621