Accuracy of the functional method of hip joint center location: effects of limited motion and varied implementation

被引:131
作者
Piazza, SJ
Okita, N
Cavanagh, PR
机构
[1] Penn State Univ, Ctr Locomot Studies, University Pk, PA 16802 USA
[2] Penn State Univ, Dept Kinesiol, University Pk, PA 16802 USA
[3] Penn State Univ, Dept Mech & Nucl Engn, University Pk, PA 16802 USA
[4] Penn State Univ, Dept Bioengn, University Pk, PA 16802 USA
[5] Penn State Univ, Dept Biobehavioral Hlth, University Pk, PA 16802 USA
[6] Penn State Univ, Dept Med, Hershey, PA 17033 USA
[7] Penn State Univ, Dept Orthopaed & Rehabil, Hershey, PA 17033 USA
关键词
hip joint center; motion analysis; hip kinematics; range of motion;
D O I
10.1016/S0021-9290(01)00052-5
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Accurate location of the hip joint center is essential for computation of hip kinematics and kinetics as well as for determination of the moment arms of muscles crossing the hip. The functional method of hip joint center location involves fitting a pelvis-fixed sphere to the path traced by a thigh-fixed point while a subject performs hip motions, the center of this sphere is the hip joint center. The aim of the present study was to evaluate the potential accuracy of the functional method and the dependence of its accuracy on variations in its implementation and the amount of available hip motion. The motions of a mechanical linkage were studied to isolate the factors of interest, removing errors due to skin movement and the palpation of bony. landmarks that are always present in human studies. It was found that reducing the range of hip motion from 30 degrees to 15 degrees did significantly increase hip joint center location errors, but that restricting motion to a single plane did not. The magnitudes of these errors, however, even in the least accurate cases, were smaller than those previously reported for either the functional method or other methods based on pelvis measurements of living subjects and cadaver specimens. Neither increasing the number of motion data observations nor analyzing the motion of a single thigh marker (rather than the centroid of multiple markers) was found to significantly increase error. The results of this study (1) imply that the limited range of motion that is often evident in subjects with hip pathology does not preclude accurate determination of the hip joint center when the functional method is used: and (2) provide guidelines for the use of the functional method in human subjects. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:967 / 973
页数:7
相关论文
共 22 条
[1]  
ALDERINK G, 2000, GAIT POSTURE, V11, P121
[2]   A STUDY OF LOWER-LIMB MECHANICS DURING STAIR-CLIMBING [J].
ANDRIACCHI, TP ;
ANDERSSON, GBJ ;
FERMIER, RW ;
STERN, D ;
GALANTE, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (05) :749-757
[3]   PREDICTION OF HIP-JOINT CENTER LOCATION FROM EXTERNAL LANDMARKS [J].
BELL, AL ;
BRAND, RA ;
PEDERSEN, DR .
HUMAN MOVEMENT SCIENCE, 1989, 8 (01) :3-16
[4]   A COMPARISON OF THE ACCURACY OF SEVERAL HIP CENTER LOCATION PREDICTION METHODS [J].
BELL, AL ;
PEDERSEN, DR ;
BRAND, RA .
JOURNAL OF BIOMECHANICS, 1990, 23 (06) :617-621
[5]   GAIT ANALYSIS METHODOLOGY [J].
CAPPOZZO, A .
HUMAN MOVEMENT SCIENCE, 1984, 3 (1-2) :27-50
[6]   POSITION AND ORIENTATION IN-SPACE OF BONES DURING MOVEMENT - ANATOMICAL FRAME DEFINITION AND DETERMINATION [J].
CAPPOZZO, A ;
CATANI, F ;
DELLA CROCE, U ;
LEARDINI, A .
CLINICAL BIOMECHANICS, 1995, 10 (04) :171-178
[7]   A PROCEDURE FOR DETERMINING RIGID-BODY TRANSFORMATION PARAMETERS [J].
CHALLIS, JH .
JOURNAL OF BIOMECHANICS, 1995, 28 (06) :733-737
[8]  
Craig J J, 1986, Introduction to Robotics: Mechanics & Control, V3rd, DOI DOI 10.1016/0005-1098(87)90105-1
[9]   A GAIT ANALYSIS DATA-COLLECTION AND REDUCTION TECHNIQUE [J].
DAVIS, RB ;
OUNPUU, S ;
TYBURSKI, D ;
GAGE, JR .
HUMAN MOVEMENT SCIENCE, 1991, 10 (05) :575-587
[10]   EFFECTS OF HIP CENTER LOCATION ON THE MOMENT-GENERATING CAPACITY OF THE MUSCLES [J].
DELP, SL ;
MALONEY, W .
JOURNAL OF BIOMECHANICS, 1993, 26 (4-5) :485-499