Electric-field-induced flame speed modification

被引:102
作者
Marcum, SD
Ganguly, BN [1 ]
机构
[1] USAF, Res Lab, Wright Patterson AFB, OH 45433 USA
[2] Miami Univ, Dept Phys, Oxford, OH 45056 USA
关键词
hydrocarbon combustion; electric field; flame speed;
D O I
10.1016/j.combustflame.2005.04.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
The effects of pulsed and continuous DC electric fields on the reaction zones of premixed propane-air flames have been investigated using several types of experimental measurements. All observed effects on the flame are dependent on the applied voltage polarity, indicating that negatively charged flame species do not play a role in the perturbation of the reaction zone. Experiments designed to characterize the electric-field-induced modifications of the shape and size of the inner cone, and the concomitant changes in the temperature profiles of flames with equivalence ratios between 0.8 and 1.7, are also reported. High-speed two-dimensional imaging of the flame response to a pulsed DC voltage shows that the unperturbed conical flame front (laminar flow) is driven into a wrinkled laminar flamelet (cellular) geometry on a time scale of the order of 5 ms. Temperature distributions derived from thin filament pyrometry (TFP) measurements in flames perturbed by continuous DC fields show similar large changes in the reaction zone geometry, with no change in maximum flame temperature. All measurements are consistent with the observed flame perturbations being a fluid mechanical response to the applied field brought about by forcing positive flame ions counter to the flow. The resulting electric pressure decreases Lewis numbers of the ionic species and drives the effective flame Lewis number below unity. The observed increases in flame speed and the flame fronts trend toward turbulence can be described in terms of the flame front wrinkling and concomitant increase in reaction sheet area. This effect is a potentially attractive means of controlling flame fluid mechanical characteristics. The observed effects require minimal input electrical power (< I W for a I kW burner) due to the much better electric field coupling achieved in the present experiments compared to the previous studies. Published by Elsevier Inc. on behalf of The Combustion Institute.
引用
收藏
页码:27 / 36
页数:10
相关论文
共 25 条
[1]  
[Anonymous], ADV COMBUSTION METHO
[2]  
[Anonymous], COMBUSTION THEORY
[3]   ELECTRICAL CORONAS AND BURNER FLAME STABILITY [J].
BRADLEY, D ;
NASSER, SH .
COMBUSTION AND FLAME, 1984, 55 (01) :53-58
[4]  
BRADLEY D, 1974, P COMBUST INST, V15, P1023
[5]   ELECTRICAL PROPERTIES OF FLAMES - BURNER FLAMES IN LONGITUDINAL ELECTRIC FIELDS [J].
CALCOTE, HF ;
PEASE, RN .
INDUSTRIAL AND ENGINEERING CHEMISTRY, 1951, 43 (12) :2726-2731
[6]  
CALCOTE HF, 1989, FOSS FUELS COMB S PD, V25, P25
[7]  
Chattock A. P., 1899, LOND EDINB DUBLIN PH, V48, P401
[8]  
Chen JH, 1998, TWENTY-SEVENTH SYMPOSIUM (INTERNATIONAL) ON COMBUSTION, VOLS 1 AND 2, P819
[9]   The mechanism of two-dimensional pocket formation in lean premixed methane-air flames with implications to turbulent combustion [J].
Chen, JH ;
Echekki, T .
COMBUSTION AND FLAME, 1999, 116 (1-2) :15-+
[10]   Unsteady strain rate and curvature effects in turbulent premixed methane-air flames [J].
Echekki, T ;
Chen, JH .
COMBUSTION AND FLAME, 1996, 106 (1-2) :184-202