Solvent-modified solid-phase microextraction for the determination of diazepam in human plasma samples by capillary gas chromatography

被引:56
作者
Krogh, M
Grefslie, H
Rasmussen, KE
机构
[1] Institute of Pharmacy, University of Oslo, Blindern, Oslo
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 1997年 / 689卷 / 02期
关键词
diazepam;
D O I
10.1016/S0378-4347(96)00352-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes microextraction and gas chromatographic analysis of diazepam from human plasma, The method was based on immobilisation of 1.5 mu l of 1-octanol on a polyacrylate-coated fiber designed for solid-phase microextraction. The solvent-modified fibre was used to extract diazepam from the samples. The plasma sample was pre-treated to release diazepam from the protein binding. The fibre was inserted into the modified plasma sample, adjusted to pH 5.5, an internal standard was added and the mixture was carefully stirred for 4 min. The fibre with the immobilised solvent and the enriched analytes was injected into the capillary gas chromatograph. The solvent and the extracted analytes were evaporated at 300 degrees C in the split-splitless injection port of the gas chromatograph, separated on a methylsilicon capillary column and detected with a nitrogen-phosphorus detector. The method was shown to be reproducible with a detection limit of 0.10 nmol/ml in human plasma.
引用
收藏
页码:357 / 364
页数:8
相关论文
共 28 条
[1]  
[Anonymous], JPN J FORENSIC TOXIC
[2]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[3]   ANALYSIS OF SUBSTITUTED BENZENE COMPOUNDS IN GROUNDWATER USING SOLID-PHASE MICROEXTRACTION [J].
ARTHUR, CL ;
KILLAM, LM ;
MOTLAGH, S ;
LIM, M ;
POTTER, DW ;
PAWLISZYN, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1992, 26 (05) :979-983
[4]  
ARTHUR CL, 1992, LC GC-MAG SEP SCI, V10, P656
[5]   AUTOMATION AND OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION [J].
ARTHUR, CL ;
KILLAM, LM ;
BUCHHOLZ, KD ;
PAWLISZYN, J ;
BERG, JR .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1960-1966
[6]  
Belardi R.P., 1989, WATER POLLUT RES J C, V24, P179, DOI [10.2166/wqrj.1989.010, DOI 10.2166/WQRJ.1989.010]
[7]   DETERMINATION OF PHENOLS BY SOLID-PHASE MICROEXTRACTION AND GAS-CHROMATOGRAPHIC ANALYSIS [J].
BUCHHOLZ, KD ;
PAWLISZYN, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (13) :2844-2848
[8]   DETECTION OF BENZODIAZEPINES AND TRIBENZAZOLAMS BY TRIAGE(TM) - CONFIRMATION BY SOLID-PHASE EXTRACTION UTILIZING SPEC(R)CENTER-DOT-3ML-CENTER-DOT-MP3 MICROCOLUMNS AND GC-MS [J].
EDINBORO, LE ;
POKLIS, A .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1994, 18 (06) :312-316
[9]  
ELLENHORN MJ, 1988, MED TOXICOLOGY DIAGN, P580
[10]   BENZODIAZEPINE ANALYSIS BY NEGATIVE CHEMICAL-IONIZATION GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
FITZGERALD, RL ;
REXIN, DA ;
HEROLD, DA .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1993, 17 (06) :342-347