How to measure and evaluate volatile organic compound emissions from building products. A perspective

被引:91
作者
Wolkoff, P [1 ]
机构
[1] Natl Inst Occupat Hlth, Dept Indoor Climate, DK-2100 Copenhagen 0, Denmark
关键词
building products; emission testing; evaluation; indoor air quality; volatile organic compounds;
D O I
10.1016/S0048-9697(99)00019-4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The primary emissions of VOCs (e.g. solvents) from building products influence the perceived indoor air quality during the initial decay period. However, secondary emissions will continue thereafter (chemical or physical degradation, e.g. oxidation, hydrolysis, mechanical wear, maintenance), in addition to sorption processes. Emission testing for primary VOC emissions is necessary, but insufficient to characterise the impact of building products in their entire life span on the perceived air quality. Methods to distinguish between the two types of emissions are required. Also, the influence of climate parameters on the emission rates is necessary to know for proper testing. Future product development and selection strategies of new building products should consider the secondary emissions, in addition to the contribution from the use of auxiliary agents for cleaning, maintenance, and other potential impacts either physical or chemical in nature. Some of the requirements for emission testing are discussed in terms of secondary vs. primary emissions in order to develop 'healthier/better' building products for the indoor environment. In addition, some of the assumptions about the possible impact of VOCs on health and comfort in the indoor environment are presented. Odour thresholds for VOCs are one or more orders of magnitude lower than the corresponding airway irritation estimates, and it also appears that chemically non-reactive VOCs are not sufficiently strong irritants to cause airway irritation at concentrations normally encountered indoors. Finally, future requirements for analytical laboratory performances is proposed to accommodate the increasing need to establish which VOCs may be responsible for the perception of odour intensity from building products. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:197 / 213
页数:17
相关论文
共 101 条
[1]  
Alarie Y, 1973, CRC Crit Rev Toxicol, V2, P299, DOI 10.3109/10408447309082020
[2]   TVOC and health in non-industrial indoor environments - Report from a Nordic scientific consensus meeting at Langholmen in Stockholm, 1996 [J].
Andersson, K ;
Bakke, JV ;
Bjorseth, O ;
Bornehag, CG ;
Clausen, G ;
Hongslo, JK ;
Kjellman, M ;
Kjaergaard, S ;
Levy, F ;
Molhave, L ;
Skerfving, S ;
Sundell, J .
INDOOR AIR, 1997, 7 (02) :78-91
[3]  
[Anonymous], 1989, EURO REP STUD
[4]  
[Anonymous], 1991, INDOOR AIR
[5]  
*ASTM, 1997, D511697
[6]  
*ASTM, 1984, E98184
[7]   Environmental chemicals relevant for respiratory hypersensitivity: The indoor environment [J].
Becher, R ;
Hongslo, JK ;
Jantunen, MJ ;
Dybing, E .
TOXICOLOGY LETTERS, 1996, 86 (2-3) :155-162
[8]  
Bergeron P, 1996, J ENDOVASC SURG, V3, P1, DOI 10.1583/1074-6218(1996)003<0001:SSOCDT>2.0.CO
[9]  
2
[10]   THEORY AND METHOD OF SENSORY EVALUATION OF COMPLEX GAS-MIXTURES [J].
BERGLUND, B ;
LINDVALL, T .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES-SERIES, 1992, 641 :277-293