Improvement in the assessment of wear of total knee replacements using coordinate-measuring machine techniques

被引:25
作者
Blunt, L. A. [1 ]
Bills, P. J. [1 ]
Jiang, X-Q [1 ]
Chakrabarty, G. [2 ]
机构
[1] Univ Huddersfield, Sch Comp & Engn, Ctr Precis Technol, Huddersfield HD1 1DH, W Yorkshire, England
[2] Huddersfield Royal Infirm, Huddersfield, W Yorkshire, England
关键词
wear assessment; total knee replacement; coordinate-measuring machine technique;
D O I
10.1243/09544119JEIM289
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Total joint replacement is one of the most common elective surgical procedures performed worldwide, with an estimate of 1.5 x 10(6) operations performed annually. Currently joint replacements are expected to function for 10-15 years; however, with an increase in life expectancy, and a greater call for knee replacement due to increased activity levels, there is a requirement to improve their function to offer longer-term improved quality of life for patients. Wear analysis of total joint replacements has long been an important means in determining failure mechanisms and improving longevity of these devices. The effectiveness of the coordinate-measuring machine (CMM) technique for assessing volumetric material loss during simulated life testing of a replacement knee joint has been proved previously by the present authors. The purpose of the current work is to present an improvement to this method for situations where no pre-wear data are available. To validate the method, simulator tests were run and gravimetric measurements taken throughout the test, such that the components measured had a known wear value. The implications of the results are then discussed in terms of assessment of joint functionality and development of standardized CMM-based product standards. The method was then expanded to allow assessment of clinically retrieved bearings so as to ascertain a measure of true clinical wear.
引用
收藏
页码:309 / 318
页数:10
相关论文
共 15 条
[1]
BECKER A, 2006, P 52 ANN M ORTH RES
[2]
A metrology solution for the orthopaedic industry [J].
Bills, P. ;
Brown, L. ;
Jiang, X. ;
Blunt, L. .
7th International Symposium on Measurement Technology and Intelligent Instruments, 2005, 13 :316-319
[3]
Blunn GW, 2003, FRICTION, LUBRICATION, AND WEAR OF ARTIFICIAL JOINTS, P113
[4]
*BS ISO, 2000, 1424322000 BS ISO
[5]
*BS ISO, 2002, 1424312002 BS ISO 1
[6]
Development of a six station knee wear simulator and preliminary wear results [J].
Burgess, IC ;
Kolar, M ;
Cunningham, JL ;
Unsworth, A .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (01) :37-47
[7]
COMPARATIVE-STUDY OF THE WEAR OF UHMWPE WITH ZIRCONIA CERAMIC AND STAINLESS-STEEL FEMORAL HEADS IN ARTIFICIAL HIP JOINTS [J].
DERBYSHIRE, B ;
FISHER, J ;
DOWSON, D ;
HARDAKER, C ;
BRUMMITT, K .
MEDICAL ENGINEERING & PHYSICS, 1994, 16 (03) :229-236
[8]
Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus [J].
Jin, ZM ;
Dowson, D ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (03) :247-256
[9]
Fundamental study for all-ceramic artificial hip joint [J].
Kusaka, J ;
Takashima, K ;
Yamane, D ;
Ikeuchi, K .
WEAR, 1999, 225 :734-742
[10]
3-DIMENSIONAL KINEMATICS OF THE HUMAN KNEE DURING WALKING [J].
LAFORTUNE, MA ;
CAVANAGH, PR ;
SOMMER, HJ ;
KALENAK, A .
JOURNAL OF BIOMECHANICS, 1992, 25 (04) :347-357