Zero-loss energy filtering under low-dose conditions using a post-column energy filter

被引:30
作者
Grimm, R
Koster, AJ
Ziese, U
Typke, D
Baumeister, W
机构
来源
JOURNAL OF MICROSCOPY-OXFORD | 1996年 / 183卷
关键词
EFTEM; electron cryomicroscopy; energy filtering; Fourier ring correlation; low dose; Thermoplasma; TMV; vesicle; zero-loss filtering;
D O I
10.1046/j.1365-2818.1996.77441.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
Electron cryomicroscopy combined with energy filtering can be performed under low-dose conditions using a post-column energy filter. The microscope combined with the filter is set up such that it can be used with similar ease as a conventional microscope, the main difference being that all filter and microscope control is performed through a central computer and images are recorded with a cooled slow-scan CCD camera. The microscope can also still be used for regular imaging on film as without the filter. Owing to the 18 times post-magnification of the filter, the microscope normally has to be operated at a small magnifications, e.g. 3000x, and the beam has to be contracted to a small spot, e.g. 5 mm, in the plane of the microscope viewing screen. Computer control allows one to perform a variety of tasks automatically, such as autofocusing, thickness measurements, most-probable-loss imaging. CCD spot-scanning and tonography. The gain in contrast due to zero-loss energy filtering is analysed using visual inspection, power spectra and Fourier ring correlation. The thickness range for ice-embedded specimens in which a filter at 120 kV is most useful appears to be between 100 and 300 nm.
引用
收藏
页码:60 / 68
页数:9
相关论文
共 12 条
[1]   TOWARDS AUTOMATIC ELECTRON TOMOGRAPHY [J].
DIERKSEN, K ;
TYPKE, D ;
HEGERL, R ;
KOSTER, AJ ;
BAUMEISTER, W .
ULTRAMICROSCOPY, 1992, 40 (01) :71-87
[2]   TOWARDS AUTOMATIC ELECTRON TOMOGRAPHY .2. IMPLEMENTATION OF AUTOFOCUS AND LOW-DOSE PROCEDURES [J].
DIERKSEN, K ;
TYPKE, D ;
HEGERL, R ;
BAUMEISTER, W .
ULTRAMICROSCOPY, 1993, 49 (1-4) :109-120
[3]   APPROACHES TO LARGE-SCALE STRUCTURES [J].
FRANK, J .
CURRENT OPINION IN STRUCTURAL BIOLOGY, 1995, 5 (02) :194-201
[4]  
GRIMM R, 1996, IN PRESS ULTRAMICROS
[5]   INFLUENCE OF ZERO-LOSS FILTERING ON ELECTRON-OPTICAL PHASE-CONTRAST [J].
HIRSCH, P ;
REIMER, L .
JOURNAL OF MICROSCOPY-OXFORD, 1994, 174 :143-148
[6]   PRACTICAL AUTOALIGNMENT OF TRANSMISSION ELECTRON-MICROSCOPES [J].
KOSTER, AJ ;
DERUIJTER, WJ .
ULTRAMICROSCOPY, 1992, 40 (02) :89-107
[7]   DEVELOPMENTS IN EELS INSTRUMENTATION FOR SPECTROSCOPY AND IMAGING [J].
KRIVANEK, OL ;
GUBBENS, AJ ;
DELLBY, N .
MICROSCOPY MICROANALYSIS MICROSTRUCTURES, 1991, 2 (2-3) :315-332
[8]   AN IMAGING FILTER FOR BIOLOGICAL APPLICATIONS [J].
KRIVANEK, OL ;
FRIEDMAN, SL ;
GUBBENS, AJ ;
KRAUS, B .
ULTRAMICROSCOPY, 1995, 59 (1-4) :267-282
[9]   QUANTITATIVE ENERGY-FILTERED ELECTRON-MICROSCOPY OF BIOLOGICAL MOLECULES IN ICE [J].
LANGMORE, JP ;
SMITH, MF .
ULTRAMICROSCOPY, 1992, 46 (1-4) :349-373
[10]   THE CORRELATION AVERAGING OF A REGULARLY ARRANGED BACTERIAL-CELL ENVELOPE PROTEIN [J].
SAXTON, WO ;
BAUMEISTER, W .
JOURNAL OF MICROSCOPY-OXFORD, 1982, 127 (AUG) :127-138