Late incomplete stent apposition after sirolimus-eluting stent implantation - A serial intravascular ultrasound analysis

被引:191
作者
Ako, J
Morino, Y
Honda, Y
Hassan, A
Sonoda, S
Yock, PG
Leon, MB
Moses, JW
Bonneau, HN
Fitzgerald, PJ
机构
[1] Stanford Univ, Med Ctr, Ctr Res Cardiovasc Intervent, Stanford, CA 94305 USA
[2] Lenox Hill Hosp, New York, NY 10021 USA
[3] Highlands Consulting Inc, San Jose, CA USA
关键词
D O I
10.1016/j.jacc.2005.05.068
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES We sought to identify the frequency of incomplete stent apposition (ISA) in sirolimus-eluting stents (SES) and clarify its findings and clinical sequelae. BACKGROUND Late-acquired ISA has been reported in bare-metal stents (BMS) and brachytherapy and recently in drug-eluting stents. However, the characteristics of late ISA in SES have not been clarified. METHODS From the SIRIUS trial, a randomized, multicenter study comparing SES and BMS, serial qualitative intravascular ultrasound (IVUS, at stent implantation and eight-month follow-up) was available in 141 patients (BMS: n = 61; SES: n = 80). The IVUS images were reviewed for the presence of ISA. RESULTS Incomplete stent apposition at follow-up was observed in 19 patients (BMS: n = 6 [9.8%]; SES: n = 13 [16.3%]; p = NS). Among these, 12 had ISA after intervention and at follow-up (persistent ISA). Late-acquired ISA was seen in the remaining seven cases, all from the SES group (BMS: n = 0; SES: n = 7 [8.7%]; p < 0.05). In late-acquired ISA, there was an increase in external elastic membrane area (after intervention: 16.2 +/- 2.7 in 2; follow-up: 18.9 +/- 3.6 mm(2); P < 0.05). The location of stent-vessel wall separation was primarily at the stent edges in persistent ISA cases, whereas late-acquired ISA in SES occurred mostly in the mid portion of the stent. There were no negative clinical events reported for any ISA cases at 12-month clinical follow-up. CONCLUSIONS Late ISA was observed in 8.7% of patients after SES implantation. There were no negative clinical events associated with this IVUS finding at 12-month clinical follow-up; however, careful long-term follow-up will be necessary.
引用
收藏
页码:1002 / 1005
页数:4
相关论文
共 18 条
  • [1] Late coronary occlusion after intracoronary brachytherapy
    Costa, MA
    Sabaté, M
    van der Giessen, WJ
    Kay, IP
    Cervinka, P
    Ligthart, JMR
    Serrano, P
    Coen, VLMA
    Levendag, PC
    Serruys, PW
    [J]. CIRCULATION, 1999, 100 (08) : 789 - 792
  • [2] Maintenance of long-term clinical benefit with sirolimus-eluting coronary stents -: Three-year results of the RAVEL trial
    Fajadet, J
    Morice, MC
    Bode, C
    Barragan, P
    Serruys, PW
    Wijns, W
    Constantini, CR
    Guermonprez, JL
    Eltchaninoff, H
    Blanchard, D
    Bartorelli, A
    Laarman, GJ
    Perin, MA
    Sousa, JE
    Schuler, G
    Molnar, F
    Guagliumi, G
    Colombo, A
    Hayashi, EB
    Wülfert, E
    [J]. CIRCULATION, 2005, 111 (08) : 1040 - 1044
  • [3] Pathological mechanisms of fatal late coronary stent thrombosis in humans
    Farb, A
    Burke, AP
    Kolodgie, FD
    Virmani, R
    [J]. CIRCULATION, 2003, 108 (14) : 1701 - 1706
  • [4] Novel drug-delivery stent - Intravascular ultrasound observations from the first human experience with the QP2-eluting polymer stent system
    Honda, Y
    Grube, E
    de la Fuente, LM
    Yock, PG
    Stertzer, SH
    Fitzgerald, PJ
    [J]. CIRCULATION, 2001, 104 (04) : 380 - 383
  • [5] Paclitaxel coating reduces in-stent intimal hyperplasia in human coronary arteries - A serial volumetric intravascular ultrasound analysis from the ASian paclitaxel-eluting stent clinical trial (ASPECT)
    Hong, MK
    Mintz, GS
    Lee, CW
    Song, JM
    Han, KH
    Kang, DH
    Song, JK
    Kim, JJ
    Weissman, NJ
    Fearnot, NE
    Park, SW
    Park, SJ
    [J]. CIRCULATION, 2003, 107 (04) : 517 - 520
  • [6] 7-hexanoyltaxol-eluting stent for prevention of neointimal growth - An intravascular ultrasound analysis from the study to COmpare REstenosis rate between QueST and QuaDS-QP2 (SCORE)
    Kataoka, T
    Grube, E
    Honda, Y
    Morino, Y
    Hur, SH
    Bonneau, HN
    Colombo, A
    Di Mario, C
    Guagliumi, G
    Hauptmann, KE
    Pitney, MR
    Lansky, AJ
    Stertzer, SH
    Yock, PG
    Fitzgerald, PJ
    [J]. CIRCULATION, 2002, 106 (14) : 1788 - 1793
  • [7] Kozuma K, 1999, J INVASIVE CARDIOL, V11, P651
  • [8] Regional remodeling as the cause of late stent malapposition
    Mintz, GS
    Shah, VM
    Weissman, NJ
    [J]. CIRCULATION, 2003, 107 (21) : 2660 - 2663
  • [9] Intravascular ultrasound assessment of the mechanisms and results of brachytherapy
    Mintz, GS
    Weissman, NJ
    Fitzgerald, PJ
    [J]. CIRCULATION, 2001, 104 (11) : 1320 - 1325
  • [10] A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization.
    Morice, M
    Serruys, PW
    Sousa, JE
    Fajadet, J
    Hayashi, EB
    Perin, M
    Colombo, A
    Schuler, G
    Barragan, P
    Guagliumi, G
    Molnar, F
    Falotico, R
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (23) : 1773 - 1780