CFD simulation of wet cooling towers

被引:108
作者
Al-Waked, R
Behnia, M
机构
[1] Bassett Appl Res, Sydney, NSW 2060, Australia
[2] Univ Sydney, Sydney, NSW 2006, Australia
基金
澳大利亚研究理事会;
关键词
cooling tower; crosswind effect; two-phase flow; thermal performance; CFD;
D O I
10.1016/j.applthermaleng.2005.06.018
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat and mass transfer inside a natural draft wet cooling tower (NDWCT) have been investigated numerically under different operating and crosswind conditions. The three-dimensional CFD model has utilized the standard k-epsilon turbulence model as the turbulence closure. The current simulation has adopted both the Eulerian approach for the air phase and the Lagrangian approach for the water phase. The film nature of the water flow in the fill zone has been approximated by droplets flow with a given velocity. The required heat and mass transfer have been achieved by controlling the droplet velocity. At that specific droplet velocity, effects of the following operating parameters on the thermal performance of the NDWCT have been investigated: droplet diameter, inlet water temperature, number of nozzles, water flow rate and number of tracks per nozzle. As a result, the effect of crosswind velocity on the thermal performance has been found to be significant. Crosswinds with velocity magnitude higher than 7.5 m/s have enhanced the thermal performance of the NDWCT. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:382 / 395
页数:14
相关论文
共 31 条
[1]   The effect of windbreak walls on the thermal performance of natural draft dry cooling towers [J].
Al-Waked, R ;
Behnia, M .
HEAT TRANSFER ENGINEERING, 2005, 26 (08) :50-62
[2]   The performance of natural draft dry cooling towers under crosswind: CFD study [J].
Al-Waked, R ;
Behnia, M .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2004, 28 (02) :147-161
[3]  
ALWAKED R, 2003, 2 INT C HEAT TRANSF, pAR1
[4]  
ALWAKED R, 2004, 5 INT C MULT FLOW IC, P444
[5]  
DREYER A, 1998, 11 IAHR COOL TOW S C, P1
[6]   Evaporative cooling of water in a mechanical draft cooling tower [J].
Fisenko, SP ;
Brin, AA ;
Petruchik, AI .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (01) :165-177
[7]   Evaporative cooling of water in a natural draft cooling tower [J].
Fisenko, SP ;
Petruchik, AI ;
Solodukhin, AD .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2002, 45 (23) :4683-4694
[8]  
*FLUENT INC, 1999, FLUENT US GUID VERS
[9]  
FORNEIR Y, 2001, 12 IARH S COOL TOW H, V1, P31
[10]   Application of CFD to closed-wet cooling towers [J].
Gan, G ;
Riffat, SB ;
Shao, L ;
Doherty, P .
APPLIED THERMAL ENGINEERING, 2001, 21 (01) :79-92