Determination of metal ions by flow injection analysis with peroxyoxalate chemiluminescence detection

被引:18
作者
Sato, K
Tanaka, S
机构
[1] Department of Fundamental Science, College of Science and Engineering, Iwaki Mesei University, Iwaki-city
关键词
D O I
10.1006/mchj.1996.0013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Flow injection analysis (F1A)/chemiluminescence detection has been used to the determination of Al(III), Zn(II), Cd(II), and In(III). Fluorescent compound which was formed by complexation of a metal ion and g-hydroxyquinoline was excited by the chemiluminescence reaction of bis(2,4,6-trichlorophenyl)oxalate and hydrogen peroxide. The chemiluminescence emission generated from the excited fluorescent compound was measured. The influences of the flow rate, pH, organic solvent and its concentration in mobile phase have been investigated. When 1,4-dioxane was used as an organic solvent, the highest chemiluminescence intensity was obtained at about pH 7. The detection limits for the metal ions were in the 20-70 ppb range. The simultaneous determination of the metal ions have further been attempted by the high-performance liquid chromatography (HPLC)I chemiluminescence method. (C) 1996 Academic Press, Inc.
引用
收藏
页码:93 / 98
页数:6
相关论文
共 14 条
[1]   PRE-COLUMN CHELATION WITH 8-HYDROXYQUINOLINE FOR THE SIMULTANEOUS DETERMINATION OF METAL-IONS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BAIOCCHI, C ;
SAINI, G ;
BERTOLO, P ;
CARTONI, GP ;
PETTITI, G .
ANALYST, 1988, 113 (05) :805-807
[2]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF 8-HYDROXYQUINOLINE CHELATES OF ALUMINUM AND COBALT(III) [J].
HAMBALI, CS ;
HADDAD, PR .
CHROMATOGRAPHIA, 1980, 13 (10) :633-634
[3]   STOPPED-FLOW DETERMINATION OF THE PARAMETERS AFFECTING THE APPLICATION OF PEROXYOXALATE CHEMI-LUMINESCENCE TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETECTION [J].
HANAOKA, N ;
GIVENS, RS ;
SCHOWEN, RL ;
KUWANA, T .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2193-2197
[4]   APPLICATION OF HPLC TO INORGANIC ANALYSIS .7. COMPARISON BETWEEN PRE-COLUMN-DERIVATIZATION AND ON-COLUMN DERIVATIZATION FOR SEPARATION OF DIFFERENT METAL OXINATES - QUANTITATIVE-DETERMINATION OF MN(II) BESIDES MN(III) IONS [J].
HOFFMANN, BW ;
SCHWEDT, G .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1982, 5 (08) :439-440
[5]  
HOLZBECHER Z, 1983, SB VYS SK CHEM TECHN, V18, P41
[6]   SENSITIVE DETECTION OF OXO-STEROIDS AND OXO-BILE ACIDS BY LIQUID-CHROMATOGRAPHY WITH PEROXYOXALATE CHEMI-LUMINESCENCE DETECTION [J].
IMAI, K ;
HIGASHIDATE, S ;
NISHITANI, A ;
TSUKAMOTO, Y ;
ISHIBASHI, M ;
SHODA, J ;
OSUGA, T .
ANALYTICA CHIMICA ACTA, 1989, 227 (01) :21-27
[7]   DETERMINATION OF FLUORESCENT COMPOUNDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CHEMI-LUMINESCENCE DETECTION [J].
KOBAYASHI, S ;
IMAI, K .
ANALYTICAL CHEMISTRY, 1980, 52 (03) :424-427
[8]  
KUWAKMAN PJM, 1992, ANAL CHIM ACTA, V266, P175
[9]   MICROBORE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND CHEMI-LUMINESCENCE DETECTION OF DNS-AMINO ACIDS [J].
MIYAGUCHI, K ;
HONDA, K ;
IMAI, K .
JOURNAL OF CHROMATOGRAPHY, 1984, 316 (DEC) :501-505
[10]  
RODENBURG PHM, 1992, ANAL CHIM ACTA, V226, P233