Reproducibility measurements for ESR signal intensity and dose determination: High precision but doubtful accuracy

被引:20
作者
Grun, R [1 ]
机构
[1] Australian Natl Univ, Res Sch Earth Sci, Canberra, ACT 0200, Australia
关键词
D O I
10.1016/S1350-4487(98)00014-6
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Reproducibility measurements on fossil tooth enamel show that the intensity of the main signal can be measured with high precision(< 1%). Dose response curves based on conventional peak-to-peak measurements yield doses with errors in the range of 1-3.5%. The most appropriate weighting model for exponential regression is the experimentally determined variance; a model using weights inversely proportional to intensity squared also gives sensible results. Dose versus magnetic field plots on derivative and absorption spectra yield dose values with similar high precisions. However, these plots cast doubt on the general validity of ESR dose assessments from complex ESR spectra such as fossil tooth enamel. Meaningful spectrum deconvolution is urgently required for the estimation of reliable dose values. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:177 / 193
页数:17
相关论文
共 29 条
[1]  
Abragam A., 1986, ELECT PARAMAGNETIC R
[2]  
Aitken M.J., 1985, Thermoluminescence Dating
[3]  
BERGER GW, 1989, ANCIENT TL, V7, P27
[4]   Q-BAND ESR STUDIES OF FOSSIL TEETH - CONSEQUENCES FOR ESR DATING [J].
BOUCHEZ, R ;
COX, R ;
HERVE, A ;
LOPEZCARRANZA, E ;
MA, JL ;
PIBOULE, M ;
POUPEAU, G ;
REY, P .
QUATERNARY SCIENCE REVIEWS, 1988, 7 (3-4) :497-501
[5]  
BRUMBY S, 1992, NUCL TRACKS RAD MEAS, V20, P595
[6]   AN EPR STUDY OF INTACT AND POWDERED HUMAN TOOTH ENAMEL DRIED AT 400-DEGREES-C [J].
CALLENS, F ;
MOENS, P ;
VERBEECK, R .
CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (06) :543-548
[7]   THE CONTRIBUTION OF CO33- AND CO2- TO THE ELECTRON-SPIN-RESONANCE SPECTRUM NEAR G = 2 OF POWDERED HUMAN TOOTH ENAMEL [J].
CALLENS, FJ ;
VERBEECK, RMH ;
MATTHYS, PFA ;
MARTENS, LC ;
BOESMAN, ER .
CALCIFIED TISSUE INTERNATIONAL, 1987, 41 (03) :124-129
[8]   The first international intercomparison of EPR-dosimetry with teeth: First results [J].
Chumak, V ;
Bailiff, I ;
Baran, N ;
Bugai, A ;
Dubovsky, S ;
Fedosov, I ;
Finin, V ;
Haskell, E ;
Hayes, R ;
Ivannikov, A ;
Kenner, G ;
Kirillov, V ;
Khamidova, L ;
Kolesnik, S ;
Liidja, G ;
Likhtarev, I ;
Lippmaa, E ;
Maksimenko, V ;
Meijer, A ;
Minenko, V ;
Pasalskaya, L ;
Past, J ;
Puskar, J ;
Radchuk, V ;
Sholom, S ;
Skvortzov, V ;
Stepanenko, V ;
Vaher, U ;
Wieser, A .
APPLIED RADIATION AND ISOTOPES, 1996, 47 (11-12) :1281-1286
[9]   An approach to the assessment of overall uncertainty of determination of dose using an ESR technique [J].
Chumak, V ;
Pavlenko, J ;
Sholom, S .
APPLIED RADIATION AND ISOTOPES, 1996, 47 (11-12) :1287-1291
[10]   AMS C-14 analysis of teeth from archaeological sites showing anomalous ESR dating results [J].
Grun, R ;
Abeyratne, M ;
Head, J ;
Tuniz, C ;
Hedges, REM .
QUATERNARY SCIENCE REVIEWS, 1997, 16 (3-5) :437-444