Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when installing Endosseous implants in the interforaminal region

被引:80
作者
Uchida, Yuki
Yamashita, Yoshio
Goto, Masaaki
Hanihara, Tsunehiko
机构
[1] Saga Med Sch, Dept Oral & Maxillofacial Surg, Saga, Japan
[2] Saga Med Sch, Dept Anat, Saga, Japan
关键词
D O I
10.1016/j.joms.2006.10.015
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
Purpose: To measure the anterior loop length (ALL) for the mandibular canal and diameter of the mandibular incisive canal at various points to ascertain the mesial distance from the mental foramen at which it is safe to install endosseous implants in the most distal area. of the interforaminal region. Patients and Methods: Using 38 cadavers (75 hemimandibles), the ALL and the diameter of the incisive canal at its origin and at 1 mm intervals up to 5 mm mesially from the origin were measured using operative calipers. Results: Measured data are expressed as minimum, maximum, and mean +/- standard deviation. ALL was 0.0, 6.0, and 1.5 +/- 1.4 mm, the diameter of the incisive canal was 1.0, 6.6, and 3.1 +/- 1.2 mm at the origin, 0.6, 5.8, and 2.6 +/- 1.1 mm at 1 mm, 0.5, 5.7, and 2.2 +/- 1.0 mm at 2 mm, 0.5, 6.0, and 2.0 +/- 1.0 mm at 3 mm, 0.5, 5.0, and 1.8 +/- 0.8 mm at 4 mm, and 0.5, 4.9, and 1.7 +/- 0.8 mm at 5 mm mesially. Conclusion: The above results showed that because there may be large variations in the ALL and the diameter of the incisive canal, one should not assume that a fixed distance mesially from the mental foramen will be safe. Intraoperative examination of vital structures is indispensable for the safe installation of implants in the interforaminal area of the mandible. Not only the ALL but also the diameter of the incisive canal should be investigated on a case-by-case basis to determine the appropriate location for each individual. (C) 2007 American Association of Oral and Maxillofacial Surgeons.
引用
收藏
页码:1772 / 1779
页数:8
相关论文
共 15 条
[1]
ADELL R, 1992, TISSUE INTEGRATED PR, P215
[2]
Arzouman M J, 1993, Int J Oral Maxillofac Implants, V8, P295
[3]
Bavitz J B, 1993, Int J Oral Maxillofac Implants, V8, P563
[4]
FIXTURE STABILITY AND NERVE FUNCTION AFTER TRANSPOSITION AND LATERALIZATION OF THE INFERIOR ALVEOLAR NERVE AND FIXTURE INSTALLATION [J].
HIRSCH, JM ;
BRANEMARK, PI .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1995, 33 (05) :276-281
[5]
Vulnerability of the inferior alveolar nerve and mental nerve during genioplasty: An anatomic study [J].
Hwang, K ;
Lee, WJ ;
Song, YB ;
Chung, IH .
JOURNAL OF CRANIOFACIAL SURGERY, 2005, 16 (01) :10-14
[6]
Kohavi D, 1996, Implant Dent, V5, P281, DOI 10.1097/00008505-199600540-00007
[7]
Anterior loop of the mental nerve: a morphological and radiographic study [J].
Kuzmanovic, DV ;
Payne, AG ;
Kieser, JA ;
Dias, GJ .
CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (04) :464-471
[8]
MAGNUSSON S, 1992, SURG PROCEDURE MAN, pDR
[9]
Anatomic and radiologic course of the mandibular incisive canal [J].
Mardinger, O ;
Chaushu, G ;
Arensburg, B ;
Taicher, S ;
Kaffe, I .
SURGICAL AND RADIOLOGIC ANATOMY, 2000, 22 (3-4) :157-161
[10]
Mardinger O, 2000, Implant Dent, V9, P120, DOI 10.1097/00008505-200009020-00003