Electroanalysis of NADH using conducting and redox active polymer/carbon nanotubes modified electrodes - A review

被引:123
作者
Kumar, S. Ashok [1 ]
Chen, Shen-Ming [1 ]
机构
[1] Natl Taipei Univ Technol, Dept Chem Engn & Biotechnol, Taipei 106, Taiwan
关键词
electroanalysis of NADH; conducting polymer modified electrodes; electrocatalysis; polymer carbon nanotube nanocomposite; modified electrodes; sensors; chemically modified electrodes;
D O I
10.3390/s8020739
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Past few decades, conducting and redox active polymers play a critical role in the development of transducers for biosensing. It has been evidenced by increasing numerous reports on conducting and redox active polymers incorporated electrodes for assay of biomolcules. This review highlights the potential uses of electrogenerated polymer modified electrodes and polymer/carbon nanotubes composite modified electrodes for electroanalysis of reduced form of nicotinamide adenine dinuceltoide (NADH). In addition, carbon electrodes modified with organic and inorganic materials as modifier have been discussed in detail for the quantification of NADH based on mediator or mediatorless methods.
引用
收藏
页码:739 / 766
页数:28
相关论文
共 132 条
[1]   Structure of carbon fibres found on carbon arc anodes. [J].
Abrahamson, J ;
Wiles, PG ;
Rhoades, BL .
CARBON, 1999, 37 (11) :1873-1874
[2]   Conducting polymers and the bioanalytical sciences: New tools for biomolecular communications - A review [J].
Adeloju, SB ;
Wallace, GG .
ANALYST, 1996, 121 (06) :699-703
[3]   Polymers in sensor applications [J].
Adhikari, B ;
Majumdar, S .
PROGRESS IN POLYMER SCIENCE, 2004, 29 (07) :699-766
[4]   Poly-(3-methylthiophene)/carbon nanotubes hybrid composite-modified electrodes [J].
Aguei, L. ;
Pena-Farfal, C. ;
Yanez-Sedeno, P. ;
Pingarron, J. M. .
ELECTROCHIMICA ACTA, 2007, 52 (28) :7946-7952
[5]   Nanotubes from carbon [J].
Ajayan, PM .
CHEMICAL REVIEWS, 1999, 99 (07) :1787-1799
[6]  
[Anonymous], 1997, HDB ORGANIC CONDUCTI
[7]   Gas sensors based on conducting polymers [J].
Bai, Hua ;
Shi, Gaoquan .
SENSORS, 2007, 7 (03) :267-307
[8]   Electrocatalysis at graphite and carbon nanotube modified electrodes: edge-plane sites and tube ends are the reactive sites [J].
Banks, CE ;
Davies, TJ ;
Wildgoose, GG ;
Compton, RG .
CHEMICAL COMMUNICATIONS, 2005, (07) :829-841
[9]  
Barlett P., 1993, J ELECTROANAL CHEM, V362, P1, DOI DOI 10.1016/0022-0728(93)80001-X
[10]   DETERMINATION OF ENZYME-ACTIVITY IN BIOLOGICAL-FLUIDS BY MEANS OF THE ELECTROCHEMICAL OXIDATION OF NADH AT A MODIFIED GLASSY-CARBON ELECTRODE [J].
BARTALITS, L ;
NAGY, G ;
PUNGOR, E .
ANALYTICAL LETTERS PART B-CLINICAL AND BIOCHEMICAL ANALYSIS, 1984, 17 (01) :13-41