Java']Java-based graphical user interface for the MRUI quantitation package

被引:360
作者
Naressi, A
Couturier, C
Devos, JM
Janssen, M
Mangeat, C
de Beer, R
Graveron-Demilly, D
机构
[1] Univ Lyon 1, Lab RMN, CNRS UMR Q5012, CPE, F-69622 Villeurbanne, France
[2] Natl Tech Univ Athens, Signal Proc Lab, Athens, Greece
[3] Delft Univ Technol, Dept Appl Phys, NL-2600 GA Delft, Netherlands
[4] Univ Leipzig, Fac Phys & Geowissensch, D-7010 Leipzig, Germany
关键词
!text type='Java']Java[!/text; graphical user interface (GUI); magnetic resonance spectroscopy (MRS); quantitation; MRUI package;
D O I
10.1007/BF02668096
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This article describes the Java-based version of the magnetic resonance user interface (MRUI) quantitation package. This package allows MR spectroscopists to easily perform time-domain analysis of in vivo MR spectroscopy data. We show that the Java pro-ramming language is very well suited for developing highly interactive graphical software applications such as the MRUI software. We have also established that MR quantitation algorithms, programmed in other languages, can easily be embedded into the Java-based MRUI by using the Java native interface (JNI). This new graphical user interface (GUI) has been conceived for the processing of large data sets and uses prior knowledge data-bases to make interactive quantitation algorithms more userfriendly. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:141 / 152
页数:12
相关论文
共 43 条
[1]  
AMBLER SW, UNIFIED MODELING LAN
[2]   Water peak suppression: Time-frequency vs time-scale approach [J].
Antoine, JP ;
Coron, A ;
Dereppe, JM .
JOURNAL OF MAGNETIC RESONANCE, 2000, 144 (02) :189-194
[3]  
Arnold Ken., 1996, The Java Programming Language
[4]   The continuous wavelet transform, an analysis tool for NMR spectroscopy [J].
Barache, D ;
Antoine, JP ;
Dereppe, JM .
JOURNAL OF MAGNETIC RESONANCE, 1997, 128 (01) :1-11
[5]   IMPROVED ALGORITHM FOR NONITERATIVE TIME-DOMAIN MODEL-FITTING TO EXPONENTIALLY DAMPED MAGNETIC-RESONANCE SIGNALS [J].
BARKHUIJSEN, H ;
DEBEER, R ;
VANORMONDT, D .
JOURNAL OF MAGNETIC RESONANCE, 1987, 73 (03) :553-557
[6]   ERROR THEORY FOR TIME-DOMAIN SIGNAL ANALYSIS WITH LINEAR PREDICTION AND SINGULAR VALUE DECOMPOSITION [J].
BARKHUIJSEN, H ;
DEBEER, R ;
VANORMONDT, D .
JOURNAL OF MAGNETIC RESONANCE, 1986, 67 (02) :371-375
[7]   RETRIEVAL OF FREQUENCIES, AMPLITUDES, DAMPING FACTORS, AND PHASES FROM TIME-DOMAIN SIGNALS USING A LINEAR LEAST-SQUARES PROCEDURE [J].
BARKHUIJSEN, H ;
DEBEER, R ;
BOVEE, WMMJ ;
VANORMONDT, D .
JOURNAL OF MAGNETIC RESONANCE, 1985, 61 (03) :465-481
[8]  
BOOCH G, 1994, OBJECT ORIENTED ANAL
[9]   Cramer-Rao bound expressions for parametric estimation of overlapping peaks: Influence of prior knowledge [J].
Cavassila, S ;
Deval, S ;
Huegen, C ;
van Ormondt, D ;
Graveron-Demilly, D .
JOURNAL OF MAGNETIC RESONANCE, 2000, 143 (02) :311-320
[10]   The beneficial influence of prior knowledge on the quantitation of in vivo magnetic resonance spectroscopy signals [J].
Cavassila, S ;
Deval, S ;
Huegen, C ;
Van Ormondt, D ;
Graveron-Demilly, D .
INVESTIGATIVE RADIOLOGY, 1999, 34 (03) :242-246