Comparison of Bactec 9240 and Difco ESP blood culture systems for detection of organisms from vials whose entry was delayed

被引:20
作者
Chapin, K
Lauderdale, TL
机构
关键词
D O I
10.1128/JCM.34.3.543-549.1996
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
A comparison of the Bactec 9240 (Becton-Dickinson, Sparks, Md.) and Difco ESP (Difco Laboratories, Detroit, Mich.) instruments for the detection of organism growth from vials whose entry was delayed was evaluated. The instruments' capabilities for organism recovery, time to detection, rates of false-positive results, and numbers of vials in which growth was not detected were made by using seeded blood culture vial pairs and controls with and without delayed entry. Bactec 9240 and Difco ESP aerobic and anaerobic vials were inoculated with human blood and were seeded with organism growth from 18 species, including obligate aerobic, anaerobic, and facultative anaerobic organisms. Each organism was tested in triplicate at 0, 8, 24, 36, and 48 h and was incubated at both room temperature (RT) and 35 degrees C. Two separate phases of the study were performed, each with a different version of Bactec 9240 software. Overall, detection of growth in vials with delayed entry into either the Bactec 9240 or the Difco ESP instrument resulted in an increased total time to detection with incubation at both RT and 35 degrees C compared with the total time to detection for nondelayed vials. However, false-positive results and vials in which growth was not detected were minimal, and delayed entry did not require routine entry or exit subcultures for either system. Analysis of individual time points and incubation temperatures for the detection of all organisms suggested that Difco ESP vials delayed by up to 8 h may be incubated at 35 degrees C (100% detection) and vials delayed for longer than 8 h may remain at RT. Bactec 9240 vials may be incubated at 35 degrees C for up to 24 h with a minimal loss of detection (97.9% detection), and vials delayed for more than 24 h should remain at RT for optimal recovery of organism growth.
引用
收藏
页码:543 / 549
页数:7
相关论文
共 12 条
[1]  
BERGOGNEBEREZIN E, 1994, 53 ANN M SWISS SOC M
[2]  
KOCZMAN CL, 1995, 95 GEN M AM SOC MICR, P3
[3]  
MAIL D, 1993, 7 ANN INT C RAP METH
[4]  
MOIR P, 1995, 95 GEN M AM SOC MICR, P1
[5]   DETECTION OF BACTEREMIA BY DIFCO ESP BLOOD CULTURE SYSTEM [J].
MORELLO, JA ;
LEITCH, C ;
NITZ, S ;
DYKE, JW ;
ANDRUSZEWSKI, M ;
MAIER, G ;
LANDAU, W ;
BEARD, MA .
JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (03) :811-818
[6]  
MULLERSERIEYS C, 1995, 19 INT C CHEM I MED
[7]   MULTICENTER CLINICAL-EVALUATION OF A CONTINUOUS MONITORING BLOOD CULTURE SYSTEM USING FLUORESCENT-SENSOR TECHNOLOGY (BACTEC-9240) [J].
NOLTE, FS ;
WILLIAMS, JM ;
JERRIS, RC ;
MORELLO, JA ;
LEITCH, CD ;
MATUSHEK, S ;
SCHWABE, LD ;
DORIGAN, F ;
KOCKA, FE .
JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (03) :552-557
[8]  
STIERITZ E, 1994, 94 GEN M AM SOC MICR, P506
[9]  
SULLIVAN NM, 1994, 94 GEN M AM SOC MICR, P504
[10]   COMPARISON OF AUTOMATED DIFCO ESP BLOOD CULTURE SYSTEM WITH BIPHASIC BBL SEPTI-CHEK SYSTEM FOR DETECTION OF BLOOD-STREAM INFECTIONS IN PEDIATRIC-PATIENTS [J].
WELBY, PL ;
KELLER, DS ;
STORCH, GA .
JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (05) :1084-1088