Chemiluminescence flow-through sensor for copper based on an anodic stripping voltammetric flow cell and an ion-exchange column with immobilized reagents

被引:62
作者
Qin, W
Zhang, ZJ [1 ]
Liu, HJ
机构
[1] Nanjing Univ, Dept Chem, Nanjing 210008, Peoples R China
[2] Shaanxi Normal Univ, Dept Chem, Xian 710062, Peoples R China
关键词
D O I
10.1021/ac970917p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel chemiluminescence (CL) flow-through sensor based on immobilizing all the ingredients involved in the analytical reaction for the determination of copper is proposed. The analytical reagents including luminol and cyanide were coimmobilized permanently on an anion-exchange column, while the analyte copper was retained temporarily by electrochemical preconcentration on a gold electrode placed in an anodic stripping voltammetric now cell. By injection of a volume of sodium hydroxide through the column with immobilized reagents, luminol and cyanide were eluted from the resins in alkaline aqueous solution and then reacted with copper stripped from the gold electrode to produce a CL signal, by means of which copper could be sensed. The sensor was not susceptible to interference by other metal ions associated with the CL reaction. The response to the concentration of copper was linear in the range of 0.01-10 mu g/L and an extremely low detection limit of 8.0 x 10(-3) mu g/L was achieved. A complete analysis could be performed in 4 min with a relative standard deviation of less than 8%. The column with immobilized reagents was readily prepared and could be reused over 200 times. The sensor was applied successfully to the determination of copper in human serum and natural water samples.
引用
收藏
页码:3579 / 3584
页数:6
相关论文
共 22 条
[1]   CHEMILUMINESCENT FLOW-INJECTION ANALYSIS OF GLUCOSE IN DRINKS WITH A BIENZYME FIBEROPTIC BIOSENSOR [J].
BLUM, LJ .
ENZYME AND MICROBIAL TECHNOLOGY, 1993, 15 (05) :407-411
[2]   DETERMINATION OF COPPER IN SEA-WATER USING A FLOW-INJECTION METHOD WITH CHEMILUMINESCENCE DETECTION [J].
COALE, KH ;
JOHNSON, KS ;
STOUT, PM ;
SAKAMOTO, CM .
ANALYTICA CHIMICA ACTA, 1992, 266 (02) :345-351
[3]   DETERMINATION OF SUBNANOMOLAR LEVELS OF IRON(II) AND TOTAL DISSOLVED IRON IN SEAWATER BY FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION [J].
ELROD, VA ;
JOHNSON, KS ;
COALE, KH .
ANALYTICAL CHEMISTRY, 1991, 63 (09) :893-898
[4]   FLOW-THROUGH OPTICAL BIOSENSOR BASED ON THE PERMANENT IMMOBILIZATION OF AN ENZYME AND TRANSIENT RETENTION OF A REACTION-PRODUCT [J].
FERNANDEZROMERO, JM ;
DECASTRO, MDL .
ANALYTICAL CHEMISTRY, 1993, 65 (21) :3048-3052
[5]   IMMOBILIZED FLUOROPHORES IN DYNAMIC CHEMI-LUMINESCENCE DETECTION OF HYDROGEN-PEROXIDE [J].
GUBITZ, G ;
VANZOONEN, P ;
GOOIJER, C ;
VELTHORST, NH ;
FREI, RW .
ANALYTICAL CHEMISTRY, 1985, 57 (11) :2071-2074
[6]   EXPERIMENTAL AND COMPUTATIONAL STUDY OF SPECIES FORMED DURING ELECTROCHEMICAL STRIPPING OXIDATION OF COPPER IN CHLORIDE MEDIA - DETERMINATION OF COPPER(II) IN THE NG 1(-1) RANGE BY STRIPPING POTENTIOMETRY [J].
JAGNER, D ;
SAHLIN, E ;
RENMAN, L .
TALANTA, 1995, 42 (10) :1447-1455
[7]   DETERMINATION OF COBALT AT PICOGRAM LEVELS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CHEMI-LUMINESCENCE DETECTION [J].
JONES, P ;
WILLIAMS, T ;
EBDON, L .
ANALYTICA CHIMICA ACTA, 1989, 217 (01) :157-163
[8]   CHEMI-LUMINESCENT AND BIOLUMINESCENT METHODS IN ANALYTICAL-CHEMISTRY - A REVIEW [J].
KRICKA, LJ ;
THORPE, GHG .
ANALYST, 1983, 108 (1292) :1274-1296
[9]   FLOW-INJECTION ASSAYS WITH CHEMILUMINESCENCE AND BIOLUMINESCENCE DETECTION - A REVIEW [J].
LEWIS, SW ;
PRICE, D ;
WORSFOLD, PJ .
JOURNAL OF BIOLUMINESCENCE AND CHEMILUMINESCENCE, 1993, 8 (04) :183-199
[10]   CHEMILUMINESCENCE SENSOR WITH URANINE IMMOBILIZED ON AN ANION-EXCHANGE RESIN FOR MONITORING FREE CHLORINE IN TAP WATER [J].
NAKAGAMA, T ;
YAMADA, M ;
HOBO, T .
ANALYTICA CHIMICA ACTA, 1990, 231 (01) :7-12