A comparison of polyglycolic acid versus type 1 collagen bioabsorbable nerve conduits in a rat model: An alternative to autografting

被引:86
作者
Waitayawinyu, Thanapong [1 ]
Parisi, Debra M. [1 ]
Miller, Brian [1 ]
Luria, Shai [1 ]
Morton, Holly J. [1 ]
Chin, Simon H. [1 ]
Trumble, Thomas E. [1 ]
机构
[1] Univ Washington, Dept Orthopaed & Sprot Med, Seattle, WA 98195 USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2007年 / 32A卷 / 10期
关键词
nerve conduit; type I collagen; polyglycolic acid; nerve repair; nerve graft;
D O I
10.1016/j.jhsa.2007.07.015
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Severe nerve injury with segmental loss requires nerve graft or conduit repair. We compared 2 synthetic, bioabsorbable nerve conduits with the gold standard of autogenous nerve grafting using histopathologic and neurophysiologic analyses. Methods: A 10-mm segment of the sciatic nerve of 45 Sprague-Dawley rats was resected, leaving a gap defect. Three experimental groups were used: 15 coaptations using type I collagen nerve conduits, 15 coaptations using polyglycolic acid (PGA) nerve conduits, and 15 coaptations using the excised segments as autogenous nerve grafts. The contralateral legs were used as unoperated controls. After 15 weeks, nerve regeneration was evaluated by measuring isometric muscle contraction force, axonal counting, wet muscle weights, and histology. Results: Statistically significant differences in the isometric muscle contraction force, axonal counts, and wet muscle weights were found between type I collagen conduit and nerve graft compared to the PGA conduit. Axonal sprouting was less organized and less dense with the PGA conduits when compared to nerve reconstruction with the type I collagen conduits and nerve grafts. Conclusions: Type I collagen conduits and autografts produced comparable results, which were significantly better than PGA conduits. The use of type I collagen conduit is a reliable alternative to nerve grafting for gaps up to 10 mm in length.
引用
收藏
页码:1521 / 1529
页数:9
相关论文
共 56 条
[1]  
Arai T, 2000, RESTOR NEUROL NEUROS, V17, P165
[2]   A COLLAGEN-BASED NERVE GUIDE CONDUIT FOR PERIPHERAL-NERVE REPAIR - AN ELECTROPHYSIOLOGICAL STUDY OF NERVE REGENERATION IN RODENTS AND NONHUMAN-PRIMATES [J].
ARCHIBALD, SJ ;
KRARUP, C ;
SHEFNER, J ;
LI, ST ;
MADISON, RD .
JOURNAL OF COMPARATIVE NEUROLOGY, 1991, 306 (04) :685-696
[3]  
ARCHIBALD SJ, 1995, J NEUROSCI, V15, P4109
[4]   SELECTIVE REINNERVATION OF DISTAL MOTOR STUMPS BY PERIPHERAL MOTOR AXONS [J].
BRUSHART, TME ;
SEILER, WA .
EXPERIMENTAL NEUROLOGY, 1987, 97 (02) :289-300
[5]   Influence of glial growth factor and Schwann cells in a bioresorbable guidance channel on peripheral nerve regeneration [J].
Bryan, DJ ;
Holway, AH ;
Wang, KK ;
Silva, AE ;
Trantolo, DJ ;
Wise, D ;
Summerhayes, IC .
TISSUE ENGINEERING, 2000, 6 (02) :129-138
[6]   Early peripheral nerve healing in collagen and silicone tube implants: Myofibroblasts and the cellular response [J].
Chamberlain, LJ ;
Yannas, IV ;
Arrizabalaga, A ;
Hsu, HP ;
Norregaard, TV ;
Spector, M .
BIOMATERIALS, 1998, 19 (15) :1393-1403
[7]   Collagen-GAG substrate enhances the quality of nerve regeneration through collagen tubes up to level of autograft [J].
Chamberlain, LJ ;
Yannas, IV ;
Hsu, HP ;
Strichartz, G ;
Spector, M .
EXPERIMENTAL NEUROLOGY, 1998, 154 (02) :315-329
[8]  
CHIU DTW, 1982, SURGERY, V91, P226
[9]   A PROSPECTIVE CLINICAL-EVALUATION OF AUTOGENOUS VEIN GRAFTS USED AS A NERVE CONDUIT FOR DISTAL SENSORY NERVE DEFECTS OF 3 CM OR LESS [J].
CHIU, DTW ;
STRAUCH, B .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1990, 86 (05) :928-934
[10]   Comparison of biodegradable conduits within aged rat sciatic nerve defects [J].
Clavijo-Alvarez, Julio A. ;
Nguyen, Vu T. ;
Santiago, Lizzie Y. ;
Doctor, John S. ;
Lee, W. P. Andrew ;
Marra, Kacey G. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2007, 119 (06) :1839-1851