Comparison of quantitative coronary angiography, intravascular ultrasound, and coronary pressure measurement to assess optimum stent deployment

被引:122
作者
Hanekamp, CEE [1 ]
Koolen, JJ [1 ]
Pijls, NHJ [1 ]
Michels, HR [1 ]
Bonnier, HJRM [1 ]
机构
[1] Catherina Hosp, Dept Cardiol, NL-5602 ZA Eindhoven, Netherlands
关键词
pressure; ultrasonics; stents; angiography;
D O I
10.1161/01.CIR.99.8.1015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Although intravascular ultrasound (IVUS) is the present standard for the evaluation of optimum stent deployment, this technique is expensive and not routinely feasible in most catheterization laboratories. Coronary pressure-derived myocardial fractional flow reserve (FFRmyo) is an easy, cheap, and rapidly obtainable index that is specific for the conductance of the epicardial coronary artery. In this study, we investigated the usefulness of coronary pressure measurement to predict optimum and suboptimum stent deployment. Methods and Results-In 30 patients, a Wiktor-i stent was implanted at different inflation pressures, starting at 6 atm and increasing step by step to 8, 10, 12, and 14 atm, if necessary. After every step, stent deployment was evaluated by quantitative coronary angiography (QCA), IVUS, and coronary pressure measurement. If any of the 3 techniques did not yield an optimum result, the next inflation was performed, and all 3 investigational modalities were repeated until optimum stent deployment was present by all of them or until the treating physician decided to accept the result. Optimum deployment according to QCA was finally achieved in 24 patients, according to IVUS in 17 patients, and also according to coronary pressure measurement in 17 patients. During the step-up, a total of 81 paired IVUS and coronary pressure measurements were performed, of which 91% yielded concordant results (ie, either an optimum or a suboptimum expansion of the stent by both techniques, P<0.00001). On the contrary, QCA showed a low concordance rate with IVUS and FFRmyo (48% and 46%, respectively). Conclusions-In this study, using a coil stent, both IVUS and coronary pressure measurement were of similar value with respect to the assessment of optimum stent deployment. Therefore, coronary pressure measurement can be used as a cheap and rapid alternative to IVUS for that purpose.
引用
收藏
页码:1015 / 1021
页数:7
相关论文
共 29 条
  • [1] INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE
    COLOMBO, A
    HALL, P
    NAKAMURA, S
    ALMAGOR, Y
    MAIELLO, L
    MARTINI, G
    GAGLIONE, A
    GOLDBERG, SL
    TOBIS, JM
    [J]. CIRCULATION, 1995, 91 (06) : 1676 - 1688
  • [2] Simultaneous coronary pressure and flow velocity measurements in humans - Feasibility, reproducibility, and hemodynamic dependence of coronary flow velocity reserve, hyperemic flow versus pressure slope index, and fractional flow reserve
    deBruyne, B
    Bartunek, J
    Sys, SU
    Pijls, NHJ
    Heyndrickx, GR
    Wijns, W
    [J]. CIRCULATION, 1996, 94 (08) : 1842 - 1849
  • [3] Clinical application and image interpretation in intracoronary ultrasound
    Di Mario, C
    Gorge, G
    Peters, R
    Kearney, P
    Pinto, F
    Hausmann, D
    von Birgelen, C
    Colombo, A
    Mudra, H
    Roelandt, J
    Erbel, R
    [J]. EUROPEAN HEART JOURNAL, 1998, 19 (02) : 207 - 229
  • [4] Fernandez-Aviles F., 1997, Journal of the American College of Cardiology, V29, p369A
  • [5] A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE
    FISCHMAN, DL
    LEON, MB
    BAIM, DS
    SCHATZ, RA
    SAVAGE, MP
    PENN, I
    DETRE, K
    VELTRI, L
    RICCI, D
    NOBUYOSHI, M
    CLEMAN, M
    HEUSER, R
    ALMOND, D
    TEIRSTEIN, PS
    FISH, RD
    COLOMBO, A
    BRINKER, J
    MOSES, J
    SHAKNOVICH, A
    HIRSHFELD, J
    BAILEY, S
    ELLIS, S
    RAKE, R
    GOLDBERG, S
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 496 - 501
  • [6] BENEFIT OF INTRACORONARY ULTRASOUND IN THE DEPLOYMENT OF PALMAZ-SCHATZ STENTS
    GOLDBERG, SL
    COLOMBO, A
    NAKAMURA, S
    ALMAGOR, Y
    MAIELLO, L
    TOBIS, JM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (04) : 996 - 1003
  • [7] INTRAVASCULAR ULTRASOUND AFTER LOW AND HIGH INFLATION PRESSURE CORONARY-ARTERY STENT IMPLANTATION
    GORGE, G
    HAUDE, M
    VOEGELE, E
    GERBER, T
    RUPPRECHT, HJ
    MEYER, J
    ERBEL, R
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (03) : 725 - 730
  • [8] Hausleiter J, 1996, CATHETER CARDIO DIAG, V37, P14
  • [9] From research to clinical practice: Current role of intracoronary physiologically based decision making in the cardiac catheterization laboratory
    Kern, MJ
    deBruyne, B
    Pijls, NHJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (03) : 613 - 620
  • [10] Three-year follow-up after implantation of metallic coronary-artery stents
    Kimura, T
    Yokoi, H
    Nakagawa, Y
    Tamura, T
    Kaburagi, S
    Sawada, Y
    Sato, Y
    Yokoi, H
    Hamasaki, N
    Nosaka, H
    Nobuyoshi, M
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (09) : 561 - 566