Preanalytical quality control program -: an overview of results (2001-2005 summary)

被引:39
作者
Alsina, M. Jesus
Alvarez, Virtudes
Barba, Nuria
Bullich, Sandra
Cortes, Mariano
Escoda, Irene
Martinez-Bru, Cecilia
机构
[1] Hospital Santa Creu I Sant Pau, 08025, Barcelona, Sant Antoni Ma Claret
关键词
external program; preanalytical mistakes; preanalytical variability; quality control; rejection; survey;
D O I
10.1515/CCLM.2008.168
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Preanalytical variables, such as sample collection, handling, transport, and storage, may affect patient results. The number of errors in the preanalytical phase may decrease by following standardized procedures. Methods: A retrospective analysis (2001-2005) of results obtained through the Spanish Society of Clinical Chemistry and Molecular Pathology Quality Assessment Program for the Preanalytical Phase has been carried out to summarize data regarding the main factors affecting the preanalytical phase quality. In such a program, participants are asked to register rejections and causes for rejection of routine or stat samples usually and locally collected at their laboratories. Results: Results discussed refer to 105 laboratories. Of the 4,715,132 tubes expected to be received during the data collection period among participating laboratories and according to determinations included by clinicians in the request form, 32,977 (0.699%) offered a cause for rejection. Whole blood-EDTA samples and serum samples accounted for 75.6% of all samples collected among laboratories, although they only corresponded to 55.8% of all registered rejections. In total, 81% of rejections arose as a result of the following reasons: "specimen not received" (37.5%), "hemolysis" (29.3%), and "clotted sample" (14.4%). Moreover, plasma-citrate-erythrocyte sedimentation rate exhibited the highest percentage of rejection (1.473%), whereas the lowest rate corresponded to whole blood-EDTA (0.381%). Conclusions: Overall percentage of rejection is similar to previously published data. As some of the included variables have turned out to be irrelevant, the program has been simplified from the year 2006 onwards.
引用
收藏
页码:849 / 854
页数:6
相关论文
共 14 条
[1]   Quality indicators and specifications for key processes in clinical laboratories:: a preliminary experience [J].
Alsina Kirchner, Ma Jesus ;
Alvarez Funes, Virtudes ;
Biosca Adzet, Carme ;
Domenech Clar, Ma Vicenta ;
Ibarz Escuer, Merce ;
Minchinela Girona, Joana ;
Pastor Barellas, Rosa Ma ;
Perich Alsina, Carmen ;
Ricos Aguila, Carmen ;
Trujillo Isern, Gloria ;
Vilanova Navarro, Conrad .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2007, 45 (05) :672-677
[2]  
ALSINA MJ, 2003, QUIM CLIN, V22, P359
[3]  
Bonini P, 2002, CLIN CHEM, V48, P691
[4]  
Dale JC, 2002, ARCH PATHOL LAB MED, V126, P416
[5]  
Howanitz PJ, 2005, ARCH PATHOL LAB MED, V129, P1252
[6]  
JONES BA, 1995, ARCH PATHOL LAB MED, V119, P203
[7]  
Jones BA, 1997, ARCH PATHOL LAB MED, V121, P19
[8]   Preanalytic error tracking in a Laboratory Medicine Department: Results of a 1-year experience [J].
Lippi, G ;
Bassi, A ;
Brocco, G ;
Montagnana, M ;
Salvagno, GL ;
Guidi, GC .
CLINICAL CHEMISTRY, 2006, 52 (07) :1442-1443
[9]   Preanalytical variability: the dark side of the moon in laboratory testing [J].
Lippi, G ;
Guidi, GC ;
Mattiuzzi, C ;
Plebani, M .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (04) :358-365
[10]   National survey on the pre-analytical variability in a representative cohort of Italian laboratories [J].
Lippi, Giuseppe ;
Montagnana, Martina ;
Giavarina, Davide .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (12) :1491-1494