Using DC resistivity method to characterize the geometry and the salinity of the Plioquaternary consolidated coastal aquifer of the Mamora plain, Morocco

被引:24
作者
Benkabbour, B
Toto, EA
Fakir, Y
机构
[1] Fac Sci, Dept Geol, Marrakech, Morocco
[2] Fac Sci & Tech, Dept Geol, Beni Mellal, Morocco
[3] Univ Ibn Tofail, Fac Sci, Dept Geol, Kenitra, Morocco
来源
ENVIRONMENTAL GEOLOGY | 2004年 / 45卷 / 04期
关键词
seawater intrusion; Plioquaternary aquifer; DC resistivity; Mamora plain; Morocco;
D O I
10.1007/s00254-003-0906-y
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The Direct Current resistivity method was applied to the consolidated coastal Plioquaternary aquifer of Mamora plain, located on the Atlantic coast of Morocco. The aim is to determine the depth of the base of the saturated zone in the aquifer and to help in imaging lateral and vertical distribution of groundwater salinity. The geoelectric survey showed four geoelectric formations with the following electrical resistivities from top to bottom: 20-80, 200-2000, 200-300 and 5-70 Ohm m. The latter designates the basement of the aquifer constituted of marls and sandy marls. The mean resistivity of 250 Ohm m designates the aquifer formation. It decreases to less than 25% of its initial values for the soundings near the shore, reflecting the oceanic impact on the aquifer formation resistivity. The contour map shows that the basement of the saturated zone in the aquifer is deeper in the Northwest near the Sebou River estuary with values up to 70 m below sea level. This results in a larger thickness of the saturated zone of the aquifer leading to a consequent hydraulic potential. On the other hand, it has been deduced that the extent of marine intrusion inside the continent can be governed by human activities, natural properties and substratum geometry of the aquifer as well as by ecological factors. An optimal network of electrical soundings has been proposed for the monitoring of saltwater intrusion.
引用
收藏
页码:518 / 526
页数:9
相关论文
共 25 条
[1]   Groundwater contamination in the basement-complex area of Ile-Ife, southwestern Nigeria: A case study using the electrical-resistivity geophysical method [J].
Adepelumi, AA ;
Ako, BD ;
Ajayi, TR .
HYDROGEOLOGY JOURNAL, 2001, 9 (06) :611-622
[2]  
[Anonymous], 1975, NOTES MEMOIRES SERV
[3]   The electrical resistivity log as an aid in determining some reservoir characteristics [J].
Archie, GE .
TRANSACTIONS OF THE AMERICAN INSTITUTE OF MINING AND METALLURGICAL ENGINEERS, 1942, 146 :54-61
[4]   DEMARCATION OF FRESH-WATER AND SALINE-WATER ZONES, USING ELECTRICAL METHODS (ABOHAR AREA, FEROZEPUR DISTRICT, PUNJAB) [J].
ARORA, CL ;
BOSE, RN .
JOURNAL OF HYDROLOGY, 1981, 49 (1-2) :75-86
[5]  
Astier J.L., 1971, GEOPHYSIQUE APPL HYD
[6]  
BENKABBOUR B, 2002, THESIS FS KENITRA MA
[7]   ELECTRICAL-RESISTIVITY SURVEYS FOR GROUNDWATER IN DECCAN TRAP COUNTRY OF SANGLI DISTRICT, MAHARASHTRA [J].
BOSE, RN ;
RAMAKRISHNA, TS .
JOURNAL OF HYDROLOGY, 1978, 38 (3-4) :209-221
[8]  
*BRGM, 1988, MAN UT GRIV
[9]  
DOMINICO PA, 1990, PHYSICAL CHEM HYDROG
[10]  
*DRPE, 1989, ET PLAN DIR INT AM E