Quantitative analysis of membrane fouling by protein mixtures using MALDI-MS

被引:24
作者
Chan, R
Chen, V [1 ]
Bucknall, MP
机构
[1] Univ New S Wales, UNESCO, Ctr Membrane Sci & Technol, Sch Chem Engn & Ind Chem, Sydney, NSW 2052, Australia
[2] Univ New S Wales, Bioanalyt Mass Spect Facil, Sydney, NSW 2052, Australia
关键词
ultrafiltration; protein fouling; critical flux; MALDI; mass spectrometry; quantification;
D O I
10.1002/bit.10866
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Binary aqueous solutions of bovine serum albumin (BSA) and beta-lactoglobulin (bLG) were subject to flux-stepping and constant flux ultrafiltration to identify the apparent critical flux and to study the mechanisms and factors affecting fouling when the membrane is permeable to one protein component. Membranes from these filtration experiments were analyzed using matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS) to locate and quantify levels of fouling below and above the apparent critical flux. Hydrophilic (PLTK) regenerated cellulose and hydrophobic (PBTK) polysulfone asymmetric membranes were used, both of 30 kDa nominal molecular weight cut-off. For the hydrophilic PLTK membrane, protein deposition was shown to depend on electrostatic forces, exhibiting little or no fouling when the proteins had the same charge sign as that of the membrane. This was found to apply for both dilute equal mass-per-unit-volume and equimolar binary mixtures. For the PBTK membrane, hydrophobic protein-membrane attractive forces were sufficiently strong to cause deposition of bLG even in the presence of repulsive electrostatic forces. For the PBTK membrane deposition exceeded monolayer coverage below and above apparent critical flux conditions but for the PLTK membrane this generally occurred when the apparent critical flux was exceeded. MALDI-MS was shown to be a facile direct analytical technique for individually quantifying adsorbed proteins on membrane surfaces at levels as low as 50 fmol/mm(2). The high levels of compound specificity inherent to mass spectrometry make this approach especially suited to the quantification of individual components in mixed deposits. In this study, MALDI-MS was found to be successful in identifying and quantifying the protein species responsible for fouling. (C) 2004 Wiley Periodicals, Inc.
引用
收藏
页码:190 / 201
页数:12
相关论文
共 57 条
[1]   PROTEIN STABILIZATION AND DESTABILIZATION BY GUANIDINIUM SALTS [J].
ARAKAWA, T ;
TIMASHEFF, SN .
BIOCHEMISTRY, 1984, 23 (25) :5924-5929
[2]  
ARNEBRANDT T, 1987, THESIS LUND U LUND
[3]   POLYETHYLENE MEMBRANE AS A SAMPLE SUPPORT FOR DIRECT MATRIX-ASSISTED LASER-DESORPTION IONIZATION MASS-SPECTROMETRIC ANALYSIS OF HIGH-MASS PROTEINS [J].
BLACKLEDGE, JA ;
ALEXANDER, AJ .
ANALYTICAL CHEMISTRY, 1995, 67 (05) :843-848
[4]   Practical quantitative biomedical applications of MALDI-TOF mass spectrometry [J].
Bucknall, M ;
Fung, KYC ;
Duncan, MW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (09) :1015-1027
[5]   SEPARATION OF PROTEINS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. OPTIMIZING THE COLUMN [J].
BURTON, WG ;
NUGENT, KD ;
SLATTERY, TK ;
SUMMERS, BR ;
SNYDER, LR .
JOURNAL OF CHROMATOGRAPHY, 1988, 443 :363-379
[6]   Ultrafiltration of protein mixtures: measurement of apparent critical flux, rejection performance, and identification of protein deposition [J].
Chan, R ;
Chen, V ;
Bucknall, MP .
DESALINATION, 2002, 146 (1-3) :83-90
[7]   The effects of electrolyte concentration and pH on protein aggregation and deposition: critical flux and constant flux membrane filtration [J].
Chan, R ;
Chen, V .
JOURNAL OF MEMBRANE SCIENCE, 2001, 185 (02) :177-192
[8]  
Chandavarkar A.S., 1990, THESIS MIT BOSTON
[9]   THE EFFECT OF PH AND IONIC ENVIRONMENT ON THE ULTRAFILTRATION OF PROTEIN SOLUTIONS WITH RETENTIVE MEMBRANES [J].
FANE, AG ;
FELL, CJD ;
SUKI, A .
JOURNAL OF MEMBRANE SCIENCE, 1983, 16 (DEC) :195-210
[10]  
Fogolari F, 2000, PROTEINS, V39, P317, DOI 10.1002/(SICI)1097-0134(20000601)39:4<317::AID-PROT50>3.0.CO