A Pilot Study of Rhythm and Timing Training as a Supplement to Occupational Therapy in Stroke Rehabilitation

被引:27
作者
Hill, Valerie [1 ]
Dunn, Leah [2 ]
Dunning, Kari [3 ,4 ]
Page, Stephen J. [5 ]
机构
[1] Xavier Univ, Dept Occupat Therapy, Cincinnati, OH 45207 USA
[2] Brown Mackie Coll, Occupat Therapy Assistant Program, Ft Mitchell, KY USA
[3] Univ Cincinnati, Coll Allied Hlth Sci, Dept Rehabil Sci, Cincinnati, OH USA
[4] Drake Ctr, Cincinnati, OH USA
[5] Ohio State Univ, Neuromotor Recovery & Rehabil Lab, Sch Allied Med Profess, Columbus, OH 43210 USA
关键词
occupational therapy; rhythm and timing training; stroke rehabilitation; RELIABILITY; VALIDITY; SENSITIVITY; PERFORMANCE; SCALE;
D O I
10.1310/tsr1806-728
中图分类号
R49 [康复医学];
学科分类号
100232 [康复医学];
摘要
Introduction: Stroke is the leading cause of disability. A need exists for an effective intervention to enhance upper extremity (UE) motor abilities and activities of daily living (ADL) performance. Objective: The objectives of this pilot study were to (1) determine the feasibility of adding Interactive Metronome (IM) to an occupational therapy (OT) program; and (2) determine changes in UE impairments, function, quality of life, and perceived physical performance ability and satisfaction using a combined IM + OT regimen compared with OT alone for adults with chronic stroke. Methods: This pilot study (n=10) used a 2-group (OT or IM+OT) pretest-posttest design. The intervention involved 60 minutes of IM + OT or OT alone, 3 days a week for 10 weeks. Outcome measures included the UE Fugl-Meyer (impairment), the Arm Motor Ability Test (function), the Box and Block Test (function), Stroke Impact Scale (quality of life), and the Canadian Occupational Performance Measure (perceived performance ability and satisfaction). Results: It was feasible to add IM to OT. The IM+OT group demonstrated decreased impairment and increased quality of life. However, the OT-alone group demonstrated greater gains in function, perceived physical performance ability, and satisfaction. Conclusion: These findings suggest that rhythm and timing training using the IM is a feasible intervention to consider as part of therapy treatment. However, IM may fit best for prefunctional treatment, as it seemed to primarily decrease impairment. It may also serve as a supplement before or after treatment in order to maximize rehabilitation potential. Clinical implications and suggestions for future studies are provided.
引用
收藏
页码:728 / 737
页数:10
相关论文
共 21 条
[1]
Clock drawing task, mini-mental state examination and cognitive-functional independence measure: relation to functional outcome of stroke patients [J].
Adunsky, A ;
Fleissig, Y ;
Levenkrohn, S ;
Arad, M ;
Noy, S .
ARCHIVES OF GERONTOLOGY AND GERIATRICS, 2002, 35 (02) :153-160
[2]
INTERRATER RELIABILITY OF A MODIFIED ASHWORTH SCALE OF MUSCLE SPASTICITY [J].
BOHANNON, RW ;
SMITH, MB .
PHYSICAL THERAPY, 1987, 67 (02) :206-207
[3]
DESROSIERS J, 1994, ARCH PHYS MED REHAB, V75, P751
[4]
The stroke impact scale version 2.0 - Evaluation of reliability, validity, and sensitivity to change [J].
Duncan, PW ;
Wallace, D ;
Lai, SM ;
Johnson, D ;
Embretson, S ;
Laster, LJ .
STROKE, 1999, 30 (10) :2131-2140
[5]
The reproducibility of the Canadian Occupational Performance Measure [J].
Eyssen, ICJM ;
Beelen, A ;
Dedding, C ;
Cardol, M ;
Dekker, J .
CLINICAL REHABILITATION, 2005, 19 (08) :888-894
[6]
FUGLMEYER AR, 1975, SCAND J REHABIL MED, V7, P13
[7]
AGONIST AND ANTAGONIST ACTIVITY DURING VOLUNTARY UPPER-LIMB MOVEMENT IN PATIENTS WITH STROKE [J].
GOWLAND, C ;
DEBRUIN, H ;
BASMAJIAN, JV ;
PLEWS, N ;
BURCEA, I .
PHYSICAL THERAPY, 1992, 72 (09) :624-633
[8]
Greenspan SI, 2001, AM J OCCUP THER, V55, P155
[9]
The arm motor ability test: Reliability, validity, and sensitivity to change of an instrument for assessing disabilities in activities of daily living [J].
Kopp, B ;
Kunkel, A ;
Flor, H ;
Platz, T ;
Rose, U ;
Mauritz, KH ;
Gresser, K ;
McCulloch, KL ;
Taub, E .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1997, 78 (06) :615-620
[10]
Kulak W, 2005, NEUROREHABILITATION, V20, P75