Development of an amperometric L-ascorbic acid (Vitamin C) sensor based on electropolymerised aniline for pharmaceutical and food analysis

被引:125
作者
O'Connell, PJ [1 ]
Gormally, C [1 ]
Pravda, M [1 ]
Guilbault, GG [1 ]
机构
[1] Natl Univ Ireland, Dept Chem, Lab Sensor Dev, Cork, Ireland
关键词
ascorbic acid; polyaniline; electropolymerisation; flow injection analysis; sensor;
D O I
10.1016/S0003-2670(00)01330-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensor has been developed that selectively catalyses the oxidation of L-ascorbic acid at low potentials (+100 mV). The low applied potential minimises the effects of many common electrochemical interferents. The interferents tested are those commonly found in juices and pharmaceutical preparations, including 4-acetamidophenol (paracetamol), uric acid and citric acid. Polyaniline was grown on both glassy carbon and screen-printed electrodes, and the analytical behaviour of both sensor types investigated. The linear ranges of the batch mode sensors were determined to be between 0.4 muM and 2 mM, with a limit of detection of 0.4 muM, while in flow injection format the linear range extended from 5 muM to 0.1 mM with a Limit of detection of 2.45 muM. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:239 / 247
页数:9
相关论文
共 22 条
[1]   A new enzyme electrode based on ascorbate oxidase immobilized in gelatin for specific determination of L-ascorbic acid [J].
Akyilmaz, E ;
Dinçkaya, E .
TALANTA, 1999, 50 (01) :87-93
[2]   Nickel (II) tetraaza macrocycle modified electrodes for the electrocatalytic determination of L-ascorbic acid by the flow injection method [J].
Bae, ZU ;
Park, JH ;
Lee, SH ;
Chang, HY .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 468 (01) :85-90
[3]  
Brett C.M.A., 1993, Electrochemistry: Principles, Methods, and Applications, DOI 10.1002/bbpc.19940981033
[4]   Electrocatalysis of ascorbic acid ion the glassy carbon electrode chemically modified with polyaniline films [J].
Casella, IG ;
Guascito, MR .
ELECTROANALYSIS, 1997, 9 (18) :1381-1386
[5]  
Combs G.F., 1992, VIT FUNDAMENTALS ASP
[6]   CATALYTIC REDUCTION OF BENZOQUINONE AT POLYANILINE AND POLYANILINE ENZYME FILMS [J].
COOPER, JC ;
HALL, EAH .
ELECTROANALYSIS, 1993, 5 (5-6) :385-397
[7]  
CUNNIFF P, 1999, OFFICIAL METHODS ANA, P16
[8]   Flow electrochemical determination of ascorbic acid in real samples using a glassy carbon electrode modified with a cellulose acetate film bearing 2,6-dichlorophenolindophenol [J].
Florou, AB ;
Prodromidis, MI ;
Karayannis, MI ;
Tzouwara-Karayanni, SM .
ANALYTICA CHIMICA ACTA, 2000, 409 (1-2) :113-121
[9]   IMPROVEMENT OF THE SELECTIVITY OF AMPEROMETRIC BIOSENSORS BY USING A PERMSELECTIVE ELECTROPOLYMERIZED FILM [J].
GROOM, CA ;
LUONG, JHT .
ANALYTICAL LETTERS, 1993, 26 (07) :1383-1390
[10]   Permeability enhancement of electropolymerized thin organic films [J].
Gros, P ;
Gibson, T ;
Bergel, A ;
Comtat, M .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 437 (1-2) :125-134